Cargando…

Pulsed Fluidization of Nanosilica: Rigorous Evaluation of the Efficacy of Pulsation Frequency

Assisted fluidization techniques can significantly improve the hydrodynamics of difficult- to-fluidize solids. Among these techniques, the pulsed flow strategy is highly promising owing to its cost-effectiveness and amenability to implementation for largescale processing. Using commercial-grade, hig...

Descripción completa

Detalles Bibliográficos
Autores principales: Asif, Mohammad, Al-Ghurabi, Ebrahim H., Fatehmulla, Amanullah
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9268123/
https://www.ncbi.nlm.nih.gov/pubmed/35807994
http://dx.doi.org/10.3390/nano12132158
_version_ 1784743899433009152
author Asif, Mohammad
Al-Ghurabi, Ebrahim H.
Fatehmulla, Amanullah
author_facet Asif, Mohammad
Al-Ghurabi, Ebrahim H.
Fatehmulla, Amanullah
author_sort Asif, Mohammad
collection PubMed
description Assisted fluidization techniques can significantly improve the hydrodynamics of difficult- to-fluidize solids. Among these techniques, the pulsed flow strategy is highly promising owing to its cost-effectiveness and amenability to implementation for largescale processing. Using commercial-grade, highly porous nanosilica that shows strong agglomeration behavior, we implemented the pulsed flow with square-wave pulsation schemes of 0.05, 0.10, and 0.25 Hz frequencies, and compared their effectiveness in each case. Besides the conventional approach of assessing their efficacy using the pressure drop data, we have proposed a new approach in this work that consists of computing the power of the overall pressure drop transient signals. Using the theoretical value, i.e., the effective bed weight per unit area as a reference, the percentage increase in the power was 27 ± 4, 71 ± 5, and 128 ± 4, respectively, for 0.05, 0.10, and 0.25 Hz pulsation frequencies. In fact, the average pressure drop values were substantially higher when the partial bed collapse occurred between successive pulsations when compared with the case of low-frequency pulsations. The pulsation frequency also affected the evolution of local bed dynamics in various bed regions during the expansion and collapse of the bed. Moreover, the local and global pressure transients have shown interesting mutual correlations which were otherwise not evident from their individual transient profiles.
format Online
Article
Text
id pubmed-9268123
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92681232022-07-09 Pulsed Fluidization of Nanosilica: Rigorous Evaluation of the Efficacy of Pulsation Frequency Asif, Mohammad Al-Ghurabi, Ebrahim H. Fatehmulla, Amanullah Nanomaterials (Basel) Article Assisted fluidization techniques can significantly improve the hydrodynamics of difficult- to-fluidize solids. Among these techniques, the pulsed flow strategy is highly promising owing to its cost-effectiveness and amenability to implementation for largescale processing. Using commercial-grade, highly porous nanosilica that shows strong agglomeration behavior, we implemented the pulsed flow with square-wave pulsation schemes of 0.05, 0.10, and 0.25 Hz frequencies, and compared their effectiveness in each case. Besides the conventional approach of assessing their efficacy using the pressure drop data, we have proposed a new approach in this work that consists of computing the power of the overall pressure drop transient signals. Using the theoretical value, i.e., the effective bed weight per unit area as a reference, the percentage increase in the power was 27 ± 4, 71 ± 5, and 128 ± 4, respectively, for 0.05, 0.10, and 0.25 Hz pulsation frequencies. In fact, the average pressure drop values were substantially higher when the partial bed collapse occurred between successive pulsations when compared with the case of low-frequency pulsations. The pulsation frequency also affected the evolution of local bed dynamics in various bed regions during the expansion and collapse of the bed. Moreover, the local and global pressure transients have shown interesting mutual correlations which were otherwise not evident from their individual transient profiles. MDPI 2022-06-23 /pmc/articles/PMC9268123/ /pubmed/35807994 http://dx.doi.org/10.3390/nano12132158 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Asif, Mohammad
Al-Ghurabi, Ebrahim H.
Fatehmulla, Amanullah
Pulsed Fluidization of Nanosilica: Rigorous Evaluation of the Efficacy of Pulsation Frequency
title Pulsed Fluidization of Nanosilica: Rigorous Evaluation of the Efficacy of Pulsation Frequency
title_full Pulsed Fluidization of Nanosilica: Rigorous Evaluation of the Efficacy of Pulsation Frequency
title_fullStr Pulsed Fluidization of Nanosilica: Rigorous Evaluation of the Efficacy of Pulsation Frequency
title_full_unstemmed Pulsed Fluidization of Nanosilica: Rigorous Evaluation of the Efficacy of Pulsation Frequency
title_short Pulsed Fluidization of Nanosilica: Rigorous Evaluation of the Efficacy of Pulsation Frequency
title_sort pulsed fluidization of nanosilica: rigorous evaluation of the efficacy of pulsation frequency
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9268123/
https://www.ncbi.nlm.nih.gov/pubmed/35807994
http://dx.doi.org/10.3390/nano12132158
work_keys_str_mv AT asifmohammad pulsedfluidizationofnanosilicarigorousevaluationoftheefficacyofpulsationfrequency
AT alghurabiebrahimh pulsedfluidizationofnanosilicarigorousevaluationoftheefficacyofpulsationfrequency
AT fatehmullaamanullah pulsedfluidizationofnanosilicarigorousevaluationoftheefficacyofpulsationfrequency