Cargando…

Tensile Modulus of Polymer Halloysite Nanotube Systems Containing Filler–Interphase Networks for Biomedical Requests

To date, there have been a limited number of studies modeling the tensile modulus in the polymer halloysite nanotube (HNT) systems before or after percolation onset. In this paper, an equation for a composite’s modulus post-percolation onset was developed for HNT-filled samples including the interph...

Descripción completa

Detalles Bibliográficos
Autores principales: Zare, Yasser, Rhee, Kyong Yop, Park, Soo-Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9268539/
https://www.ncbi.nlm.nih.gov/pubmed/35806839
http://dx.doi.org/10.3390/ma15134715
_version_ 1784744009425485824
author Zare, Yasser
Rhee, Kyong Yop
Park, Soo-Jin
author_facet Zare, Yasser
Rhee, Kyong Yop
Park, Soo-Jin
author_sort Zare, Yasser
collection PubMed
description To date, there have been a limited number of studies modeling the tensile modulus in the polymer halloysite nanotube (HNT) systems before or after percolation onset. In this paper, an equation for a composite’s modulus post-percolation onset was developed for HNT-filled samples including the interphase and HNT network. The dispersed nanoparticles and adjoining interphase part were neglected, because they caused ineffective influences on the stiffness of the system after percolation onset. The developed model reflects the impacts of HNTs’ size, interphase depth, percolation onset and the volume shares and moduli of the HNT network and its adjacent interphase on the modulus of HNT-based systems. The impacts of issues on the nanocomposite modulus are defendable, confirming the effectiveness of the developed model. HNT length, interphase depth, HNT concentration, net modulus and net portion directly influenced the stiffness, while the HNT radius and percolation onset had inverse effects. Results show that there was a 142% improvement in the modulus of samples at an interphase depth of 40 nm. Moreover, the stiffness improved by 60% at a net modulus of 200 GPa, but it later exhibited a 180% enhancement at a net modulus of 1000 GPa. In addition, the experimental data for the modulus of numerous composites display fine agreement to the predictions, confirming the validity of the developed model.
format Online
Article
Text
id pubmed-9268539
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92685392022-07-09 Tensile Modulus of Polymer Halloysite Nanotube Systems Containing Filler–Interphase Networks for Biomedical Requests Zare, Yasser Rhee, Kyong Yop Park, Soo-Jin Materials (Basel) Article To date, there have been a limited number of studies modeling the tensile modulus in the polymer halloysite nanotube (HNT) systems before or after percolation onset. In this paper, an equation for a composite’s modulus post-percolation onset was developed for HNT-filled samples including the interphase and HNT network. The dispersed nanoparticles and adjoining interphase part were neglected, because they caused ineffective influences on the stiffness of the system after percolation onset. The developed model reflects the impacts of HNTs’ size, interphase depth, percolation onset and the volume shares and moduli of the HNT network and its adjacent interphase on the modulus of HNT-based systems. The impacts of issues on the nanocomposite modulus are defendable, confirming the effectiveness of the developed model. HNT length, interphase depth, HNT concentration, net modulus and net portion directly influenced the stiffness, while the HNT radius and percolation onset had inverse effects. Results show that there was a 142% improvement in the modulus of samples at an interphase depth of 40 nm. Moreover, the stiffness improved by 60% at a net modulus of 200 GPa, but it later exhibited a 180% enhancement at a net modulus of 1000 GPa. In addition, the experimental data for the modulus of numerous composites display fine agreement to the predictions, confirming the validity of the developed model. MDPI 2022-07-05 /pmc/articles/PMC9268539/ /pubmed/35806839 http://dx.doi.org/10.3390/ma15134715 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zare, Yasser
Rhee, Kyong Yop
Park, Soo-Jin
Tensile Modulus of Polymer Halloysite Nanotube Systems Containing Filler–Interphase Networks for Biomedical Requests
title Tensile Modulus of Polymer Halloysite Nanotube Systems Containing Filler–Interphase Networks for Biomedical Requests
title_full Tensile Modulus of Polymer Halloysite Nanotube Systems Containing Filler–Interphase Networks for Biomedical Requests
title_fullStr Tensile Modulus of Polymer Halloysite Nanotube Systems Containing Filler–Interphase Networks for Biomedical Requests
title_full_unstemmed Tensile Modulus of Polymer Halloysite Nanotube Systems Containing Filler–Interphase Networks for Biomedical Requests
title_short Tensile Modulus of Polymer Halloysite Nanotube Systems Containing Filler–Interphase Networks for Biomedical Requests
title_sort tensile modulus of polymer halloysite nanotube systems containing filler–interphase networks for biomedical requests
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9268539/
https://www.ncbi.nlm.nih.gov/pubmed/35806839
http://dx.doi.org/10.3390/ma15134715
work_keys_str_mv AT zareyasser tensilemodulusofpolymerhalloysitenanotubesystemscontainingfillerinterphasenetworksforbiomedicalrequests
AT rheekyongyop tensilemodulusofpolymerhalloysitenanotubesystemscontainingfillerinterphasenetworksforbiomedicalrequests
AT parksoojin tensilemodulusofpolymerhalloysitenanotubesystemscontainingfillerinterphasenetworksforbiomedicalrequests