Cargando…

Performance Enhancement of SPR Biosensor Using Graphene–MoS(2) Hybrid Structure

We investigate a high-sensitivity surface plasmon resonance (SPR) biosensor consisting of a Au layer, four-layer MoS(2), and monolayer graphene. The numerical simulations, by the transfer matrix method (TMM), demonstrate the sensor has a maximum sensitivity of 282°/RIU, which is approximately 2 time...

Descripción completa

Detalles Bibliográficos
Autores principales: Cai, Haoyuan, Wang, Mengwei, Wu, Zhuohui, Liu, Jing, Wang, Xiaoping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9268646/
https://www.ncbi.nlm.nih.gov/pubmed/35808053
http://dx.doi.org/10.3390/nano12132219
_version_ 1784744035881058304
author Cai, Haoyuan
Wang, Mengwei
Wu, Zhuohui
Liu, Jing
Wang, Xiaoping
author_facet Cai, Haoyuan
Wang, Mengwei
Wu, Zhuohui
Liu, Jing
Wang, Xiaoping
author_sort Cai, Haoyuan
collection PubMed
description We investigate a high-sensitivity surface plasmon resonance (SPR) biosensor consisting of a Au layer, four-layer MoS(2), and monolayer graphene. The numerical simulations, by the transfer matrix method (TMM), demonstrate the sensor has a maximum sensitivity of 282°/RIU, which is approximately 2 times greater than the conventional Au-based SPR sensor. The finite difference time domain (FDTD) indicates that the presence of MoS(2) film generates a strong surface electric field and enhances the sensitivity of the proposed SPR sensor. In addition, the influence of the number of MoS(2) layers on the sensitivity of the proposed sensor is investigated by simulations and experiments. In the experiment, MoS(2) and graphene films are transferred on the Au-based substrate by the PMMA-based wet transfer method, and the fabricated samples are characterized by Raman spectroscopy. Furthermore, the fabricated sensors with the Kretschmann configuration are used to detect okadaic acid (OA). The okadaic acid–bovine serum albumin bioconjugate (OA-BSA) is immobilized on the graphene layer of the sensors to develop a competitive inhibition immunoassay. The results show that the sensor has a very low limit of detection (LOD) of 1.18 ng/mL for OA, which is about 22.6 times lower than that of a conventional Au biosensor. We believe that such a high-sensitivity SPR biosensor has potential applications for clinical diagnosis and immunoassays.
format Online
Article
Text
id pubmed-9268646
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92686462022-07-09 Performance Enhancement of SPR Biosensor Using Graphene–MoS(2) Hybrid Structure Cai, Haoyuan Wang, Mengwei Wu, Zhuohui Liu, Jing Wang, Xiaoping Nanomaterials (Basel) Article We investigate a high-sensitivity surface plasmon resonance (SPR) biosensor consisting of a Au layer, four-layer MoS(2), and monolayer graphene. The numerical simulations, by the transfer matrix method (TMM), demonstrate the sensor has a maximum sensitivity of 282°/RIU, which is approximately 2 times greater than the conventional Au-based SPR sensor. The finite difference time domain (FDTD) indicates that the presence of MoS(2) film generates a strong surface electric field and enhances the sensitivity of the proposed SPR sensor. In addition, the influence of the number of MoS(2) layers on the sensitivity of the proposed sensor is investigated by simulations and experiments. In the experiment, MoS(2) and graphene films are transferred on the Au-based substrate by the PMMA-based wet transfer method, and the fabricated samples are characterized by Raman spectroscopy. Furthermore, the fabricated sensors with the Kretschmann configuration are used to detect okadaic acid (OA). The okadaic acid–bovine serum albumin bioconjugate (OA-BSA) is immobilized on the graphene layer of the sensors to develop a competitive inhibition immunoassay. The results show that the sensor has a very low limit of detection (LOD) of 1.18 ng/mL for OA, which is about 22.6 times lower than that of a conventional Au biosensor. We believe that such a high-sensitivity SPR biosensor has potential applications for clinical diagnosis and immunoassays. MDPI 2022-06-28 /pmc/articles/PMC9268646/ /pubmed/35808053 http://dx.doi.org/10.3390/nano12132219 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Cai, Haoyuan
Wang, Mengwei
Wu, Zhuohui
Liu, Jing
Wang, Xiaoping
Performance Enhancement of SPR Biosensor Using Graphene–MoS(2) Hybrid Structure
title Performance Enhancement of SPR Biosensor Using Graphene–MoS(2) Hybrid Structure
title_full Performance Enhancement of SPR Biosensor Using Graphene–MoS(2) Hybrid Structure
title_fullStr Performance Enhancement of SPR Biosensor Using Graphene–MoS(2) Hybrid Structure
title_full_unstemmed Performance Enhancement of SPR Biosensor Using Graphene–MoS(2) Hybrid Structure
title_short Performance Enhancement of SPR Biosensor Using Graphene–MoS(2) Hybrid Structure
title_sort performance enhancement of spr biosensor using graphene–mos(2) hybrid structure
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9268646/
https://www.ncbi.nlm.nih.gov/pubmed/35808053
http://dx.doi.org/10.3390/nano12132219
work_keys_str_mv AT caihaoyuan performanceenhancementofsprbiosensorusinggraphenemos2hybridstructure
AT wangmengwei performanceenhancementofsprbiosensorusinggraphenemos2hybridstructure
AT wuzhuohui performanceenhancementofsprbiosensorusinggraphenemos2hybridstructure
AT liujing performanceenhancementofsprbiosensorusinggraphenemos2hybridstructure
AT wangxiaoping performanceenhancementofsprbiosensorusinggraphenemos2hybridstructure