Cargando…

Full-Stokes Retrieving and Configuration Optimization in a Time-Integration Imaging Polarimeter

A time-integration imaging polarimeter with continuous rotating retarder is presented, and its full-Stokes retrieving and configuration optimization are also demonstrated. The mathematical expression between the full-Stokes vector and the time-integration light intensities is derived. As a result, t...

Descripción completa

Detalles Bibliográficos
Autores principales: Gu, Naiting, Lian, Bowen, Xiao, Yawei, Huang, Linhai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9268785/
https://www.ncbi.nlm.nih.gov/pubmed/35808229
http://dx.doi.org/10.3390/s22134733
_version_ 1784744070991577088
author Gu, Naiting
Lian, Bowen
Xiao, Yawei
Huang, Linhai
author_facet Gu, Naiting
Lian, Bowen
Xiao, Yawei
Huang, Linhai
author_sort Gu, Naiting
collection PubMed
description A time-integration imaging polarimeter with continuous rotating retarder is presented, and its full-Stokes retrieving and configuration optimization are also demonstrated. The mathematical expression between the full-Stokes vector and the time-integration light intensities is derived. As a result, the state of polarization of incident light can be retrieved by only one matrix calculation. However, the modulation matrix deviates from the initial well-conditioned status due to time integration. Thus, we re-optimize the nominal angles for the special retardance of 132° and 90° with an exposure angle of 30°, which results in a reduction of 31.8% and 16.8% of condition numbers comparing to the original configuration, respectively. We also give global optimization results under different exposure angles and retardance of retarder; as a result, the 137.7° of retardance achieves a minimal condition number of 2.0, which indicates a well-conditioned polarimeter configuration. Besides, the frame-by-frame algorithm ensures the dynamic performance of the presented polarimeter. For a general brushless DC motor with a rotating speed of over 2000 rounds per minute, the speed of polarization imaging will achieve up to 270 frames per second. High precision and excellent dynamic performance, together with features of compactness, simplicity, and low cost, may give this traditional imaging polarimeter new life and attractive prospects.
format Online
Article
Text
id pubmed-9268785
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92687852022-07-09 Full-Stokes Retrieving and Configuration Optimization in a Time-Integration Imaging Polarimeter Gu, Naiting Lian, Bowen Xiao, Yawei Huang, Linhai Sensors (Basel) Article A time-integration imaging polarimeter with continuous rotating retarder is presented, and its full-Stokes retrieving and configuration optimization are also demonstrated. The mathematical expression between the full-Stokes vector and the time-integration light intensities is derived. As a result, the state of polarization of incident light can be retrieved by only one matrix calculation. However, the modulation matrix deviates from the initial well-conditioned status due to time integration. Thus, we re-optimize the nominal angles for the special retardance of 132° and 90° with an exposure angle of 30°, which results in a reduction of 31.8% and 16.8% of condition numbers comparing to the original configuration, respectively. We also give global optimization results under different exposure angles and retardance of retarder; as a result, the 137.7° of retardance achieves a minimal condition number of 2.0, which indicates a well-conditioned polarimeter configuration. Besides, the frame-by-frame algorithm ensures the dynamic performance of the presented polarimeter. For a general brushless DC motor with a rotating speed of over 2000 rounds per minute, the speed of polarization imaging will achieve up to 270 frames per second. High precision and excellent dynamic performance, together with features of compactness, simplicity, and low cost, may give this traditional imaging polarimeter new life and attractive prospects. MDPI 2022-06-23 /pmc/articles/PMC9268785/ /pubmed/35808229 http://dx.doi.org/10.3390/s22134733 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Gu, Naiting
Lian, Bowen
Xiao, Yawei
Huang, Linhai
Full-Stokes Retrieving and Configuration Optimization in a Time-Integration Imaging Polarimeter
title Full-Stokes Retrieving and Configuration Optimization in a Time-Integration Imaging Polarimeter
title_full Full-Stokes Retrieving and Configuration Optimization in a Time-Integration Imaging Polarimeter
title_fullStr Full-Stokes Retrieving and Configuration Optimization in a Time-Integration Imaging Polarimeter
title_full_unstemmed Full-Stokes Retrieving and Configuration Optimization in a Time-Integration Imaging Polarimeter
title_short Full-Stokes Retrieving and Configuration Optimization in a Time-Integration Imaging Polarimeter
title_sort full-stokes retrieving and configuration optimization in a time-integration imaging polarimeter
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9268785/
https://www.ncbi.nlm.nih.gov/pubmed/35808229
http://dx.doi.org/10.3390/s22134733
work_keys_str_mv AT gunaiting fullstokesretrievingandconfigurationoptimizationinatimeintegrationimagingpolarimeter
AT lianbowen fullstokesretrievingandconfigurationoptimizationinatimeintegrationimagingpolarimeter
AT xiaoyawei fullstokesretrievingandconfigurationoptimizationinatimeintegrationimagingpolarimeter
AT huanglinhai fullstokesretrievingandconfigurationoptimizationinatimeintegrationimagingpolarimeter