Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis
This paper improves the accuracy of quantification in the arterial diameter-dependent impedance variance by altering the electrode configuration. The finite element analysis was implemented with a 3D human wrist fragment using ANSYS Electronics Desktop, containing fat, muscle, and a blood-filled rad...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9268936/ https://www.ncbi.nlm.nih.gov/pubmed/35808233 http://dx.doi.org/10.3390/s22134736 |
_version_ | 1784744109564493824 |
---|---|
author | Yu, Yang Anand, Gautam Lowe, Andrew Zhang, Huiyang Kalra, Anubha |
author_facet | Yu, Yang Anand, Gautam Lowe, Andrew Zhang, Huiyang Kalra, Anubha |
author_sort | Yu, Yang |
collection | PubMed |
description | This paper improves the accuracy of quantification in the arterial diameter-dependent impedance variance by altering the electrode configuration. The finite element analysis was implemented with a 3D human wrist fragment using ANSYS Electronics Desktop, containing fat, muscle, and a blood-filled radial artery. Then, the skin layer and bones were stepwise added, helping to understand the dielectric response of multi-tissues and blood flow from 1 kHz to 1 MHz, the current distribution throughout the wrist, and the optimisation of electrode configurations for arterial pulse sensing. Moreover, a low-cost wrist phantom was fabricated, containing two components: the surrounding tissue simulant (20 wt % gelatine power and 0.017 M sodium chloride (NaCl) solution) and the blood simulant (0.08 M NaCl solution). The blood-filled artery was constricted using a desktop injection pump, and the impedance change was measured by the Multi-frequency Impedance Analyser (MFIA). The simulation revealed the promising capabilities of band electrodes to generate a more uniform current distribution than the traditional spot electrodes. Both simulation and phantom experimental results indicated that a longer spacing between current-carrying (CC) electrodes with shorter spacing between pick-up (PU) electrodes in the middle could sense a more uniform electric field, engendering a more accurate arterial diameter estimation. This work provided an improved electrode configuration for more accurate arterial diameter estimation from the numerical simulation and tissue phantom perspectives. |
format | Online Article Text |
id | pubmed-9268936 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-92689362022-07-09 Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis Yu, Yang Anand, Gautam Lowe, Andrew Zhang, Huiyang Kalra, Anubha Sensors (Basel) Article This paper improves the accuracy of quantification in the arterial diameter-dependent impedance variance by altering the electrode configuration. The finite element analysis was implemented with a 3D human wrist fragment using ANSYS Electronics Desktop, containing fat, muscle, and a blood-filled radial artery. Then, the skin layer and bones were stepwise added, helping to understand the dielectric response of multi-tissues and blood flow from 1 kHz to 1 MHz, the current distribution throughout the wrist, and the optimisation of electrode configurations for arterial pulse sensing. Moreover, a low-cost wrist phantom was fabricated, containing two components: the surrounding tissue simulant (20 wt % gelatine power and 0.017 M sodium chloride (NaCl) solution) and the blood simulant (0.08 M NaCl solution). The blood-filled artery was constricted using a desktop injection pump, and the impedance change was measured by the Multi-frequency Impedance Analyser (MFIA). The simulation revealed the promising capabilities of band electrodes to generate a more uniform current distribution than the traditional spot electrodes. Both simulation and phantom experimental results indicated that a longer spacing between current-carrying (CC) electrodes with shorter spacing between pick-up (PU) electrodes in the middle could sense a more uniform electric field, engendering a more accurate arterial diameter estimation. This work provided an improved electrode configuration for more accurate arterial diameter estimation from the numerical simulation and tissue phantom perspectives. MDPI 2022-06-23 /pmc/articles/PMC9268936/ /pubmed/35808233 http://dx.doi.org/10.3390/s22134736 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yu, Yang Anand, Gautam Lowe, Andrew Zhang, Huiyang Kalra, Anubha Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis |
title | Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis |
title_full | Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis |
title_fullStr | Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis |
title_full_unstemmed | Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis |
title_short | Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis |
title_sort | towards estimating arterial diameter using bioimpedance spectroscopy: a computational simulation and tissue phantom analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9268936/ https://www.ncbi.nlm.nih.gov/pubmed/35808233 http://dx.doi.org/10.3390/s22134736 |
work_keys_str_mv | AT yuyang towardsestimatingarterialdiameterusingbioimpedancespectroscopyacomputationalsimulationandtissuephantomanalysis AT anandgautam towardsestimatingarterialdiameterusingbioimpedancespectroscopyacomputationalsimulationandtissuephantomanalysis AT loweandrew towardsestimatingarterialdiameterusingbioimpedancespectroscopyacomputationalsimulationandtissuephantomanalysis AT zhanghuiyang towardsestimatingarterialdiameterusingbioimpedancespectroscopyacomputationalsimulationandtissuephantomanalysis AT kalraanubha towardsestimatingarterialdiameterusingbioimpedancespectroscopyacomputationalsimulationandtissuephantomanalysis |