Cargando…

Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis

This paper improves the accuracy of quantification in the arterial diameter-dependent impedance variance by altering the electrode configuration. The finite element analysis was implemented with a 3D human wrist fragment using ANSYS Electronics Desktop, containing fat, muscle, and a blood-filled rad...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Yang, Anand, Gautam, Lowe, Andrew, Zhang, Huiyang, Kalra, Anubha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9268936/
https://www.ncbi.nlm.nih.gov/pubmed/35808233
http://dx.doi.org/10.3390/s22134736
_version_ 1784744109564493824
author Yu, Yang
Anand, Gautam
Lowe, Andrew
Zhang, Huiyang
Kalra, Anubha
author_facet Yu, Yang
Anand, Gautam
Lowe, Andrew
Zhang, Huiyang
Kalra, Anubha
author_sort Yu, Yang
collection PubMed
description This paper improves the accuracy of quantification in the arterial diameter-dependent impedance variance by altering the electrode configuration. The finite element analysis was implemented with a 3D human wrist fragment using ANSYS Electronics Desktop, containing fat, muscle, and a blood-filled radial artery. Then, the skin layer and bones were stepwise added, helping to understand the dielectric response of multi-tissues and blood flow from 1 kHz to 1 MHz, the current distribution throughout the wrist, and the optimisation of electrode configurations for arterial pulse sensing. Moreover, a low-cost wrist phantom was fabricated, containing two components: the surrounding tissue simulant (20 wt % gelatine power and 0.017 M sodium chloride (NaCl) solution) and the blood simulant (0.08 M NaCl solution). The blood-filled artery was constricted using a desktop injection pump, and the impedance change was measured by the Multi-frequency Impedance Analyser (MFIA). The simulation revealed the promising capabilities of band electrodes to generate a more uniform current distribution than the traditional spot electrodes. Both simulation and phantom experimental results indicated that a longer spacing between current-carrying (CC) electrodes with shorter spacing between pick-up (PU) electrodes in the middle could sense a more uniform electric field, engendering a more accurate arterial diameter estimation. This work provided an improved electrode configuration for more accurate arterial diameter estimation from the numerical simulation and tissue phantom perspectives.
format Online
Article
Text
id pubmed-9268936
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92689362022-07-09 Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis Yu, Yang Anand, Gautam Lowe, Andrew Zhang, Huiyang Kalra, Anubha Sensors (Basel) Article This paper improves the accuracy of quantification in the arterial diameter-dependent impedance variance by altering the electrode configuration. The finite element analysis was implemented with a 3D human wrist fragment using ANSYS Electronics Desktop, containing fat, muscle, and a blood-filled radial artery. Then, the skin layer and bones were stepwise added, helping to understand the dielectric response of multi-tissues and blood flow from 1 kHz to 1 MHz, the current distribution throughout the wrist, and the optimisation of electrode configurations for arterial pulse sensing. Moreover, a low-cost wrist phantom was fabricated, containing two components: the surrounding tissue simulant (20 wt % gelatine power and 0.017 M sodium chloride (NaCl) solution) and the blood simulant (0.08 M NaCl solution). The blood-filled artery was constricted using a desktop injection pump, and the impedance change was measured by the Multi-frequency Impedance Analyser (MFIA). The simulation revealed the promising capabilities of band electrodes to generate a more uniform current distribution than the traditional spot electrodes. Both simulation and phantom experimental results indicated that a longer spacing between current-carrying (CC) electrodes with shorter spacing between pick-up (PU) electrodes in the middle could sense a more uniform electric field, engendering a more accurate arterial diameter estimation. This work provided an improved electrode configuration for more accurate arterial diameter estimation from the numerical simulation and tissue phantom perspectives. MDPI 2022-06-23 /pmc/articles/PMC9268936/ /pubmed/35808233 http://dx.doi.org/10.3390/s22134736 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yu, Yang
Anand, Gautam
Lowe, Andrew
Zhang, Huiyang
Kalra, Anubha
Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis
title Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis
title_full Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis
title_fullStr Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis
title_full_unstemmed Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis
title_short Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis
title_sort towards estimating arterial diameter using bioimpedance spectroscopy: a computational simulation and tissue phantom analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9268936/
https://www.ncbi.nlm.nih.gov/pubmed/35808233
http://dx.doi.org/10.3390/s22134736
work_keys_str_mv AT yuyang towardsestimatingarterialdiameterusingbioimpedancespectroscopyacomputationalsimulationandtissuephantomanalysis
AT anandgautam towardsestimatingarterialdiameterusingbioimpedancespectroscopyacomputationalsimulationandtissuephantomanalysis
AT loweandrew towardsestimatingarterialdiameterusingbioimpedancespectroscopyacomputationalsimulationandtissuephantomanalysis
AT zhanghuiyang towardsestimatingarterialdiameterusingbioimpedancespectroscopyacomputationalsimulationandtissuephantomanalysis
AT kalraanubha towardsestimatingarterialdiameterusingbioimpedancespectroscopyacomputationalsimulationandtissuephantomanalysis