Cargando…
Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars
The objective of this study was to examine the optimal mixing ratio of municipal incinerated bottom ash (MIBA) and PET pellets used as a partial replacement of fine aggregates in the manufacture of cement mortars. As a partial replacement for sand, 15 mortar specimens were prepared by mixing 0%, 10%...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9269149/ https://www.ncbi.nlm.nih.gov/pubmed/35808643 http://dx.doi.org/10.3390/polym14132597 |
_version_ | 1784744162380218368 |
---|---|
author | Phutthimethakul, Lalitsuda Supakata, Nuta |
author_facet | Phutthimethakul, Lalitsuda Supakata, Nuta |
author_sort | Phutthimethakul, Lalitsuda |
collection | PubMed |
description | The objective of this study was to examine the optimal mixing ratio of municipal incinerated bottom ash (MIBA) and PET pellets used as a partial replacement of fine aggregates in the manufacture of cement mortars. As a partial replacement for sand, 15 mortar specimens were prepared by mixing 0%, 10%, 20%, 30%, and 40% municipal incinerated bottom ash (MIBA) (A) and 0%, 10%, and 20% PET pellets (P) in 5 cm × 5 cm × 5 cm cube molds. The cement/aggregate ratio was 1:3, and the water/cement ratio was 0.5 for all specimens. The results showed that the compressive strength of cement mortars decreased when increasing the amount of MIBA and PET pellets. The mortar specimens with 10% PET pellets achieved the highest compressive strength (49.53 MPa), whereas the mortar specimens with 40% MIBA and 20% PET pellets achieved the lowest compressive strength (24.44 MPa). Based on this finding, replacing 10% and 20% sand in cement mortar with only MIBA or only PET pellets could result in compressive strengths ranging from 46.00 MPa to 49.53 MPa. |
format | Online Article Text |
id | pubmed-9269149 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-92691492022-07-09 Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars Phutthimethakul, Lalitsuda Supakata, Nuta Polymers (Basel) Article The objective of this study was to examine the optimal mixing ratio of municipal incinerated bottom ash (MIBA) and PET pellets used as a partial replacement of fine aggregates in the manufacture of cement mortars. As a partial replacement for sand, 15 mortar specimens were prepared by mixing 0%, 10%, 20%, 30%, and 40% municipal incinerated bottom ash (MIBA) (A) and 0%, 10%, and 20% PET pellets (P) in 5 cm × 5 cm × 5 cm cube molds. The cement/aggregate ratio was 1:3, and the water/cement ratio was 0.5 for all specimens. The results showed that the compressive strength of cement mortars decreased when increasing the amount of MIBA and PET pellets. The mortar specimens with 10% PET pellets achieved the highest compressive strength (49.53 MPa), whereas the mortar specimens with 40% MIBA and 20% PET pellets achieved the lowest compressive strength (24.44 MPa). Based on this finding, replacing 10% and 20% sand in cement mortar with only MIBA or only PET pellets could result in compressive strengths ranging from 46.00 MPa to 49.53 MPa. MDPI 2022-06-27 /pmc/articles/PMC9269149/ /pubmed/35808643 http://dx.doi.org/10.3390/polym14132597 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Phutthimethakul, Lalitsuda Supakata, Nuta Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars |
title | Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars |
title_full | Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars |
title_fullStr | Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars |
title_full_unstemmed | Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars |
title_short | Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars |
title_sort | partial replacement of municipal incinerated bottom ash and pet pellets as fine aggregate in cement mortars |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9269149/ https://www.ncbi.nlm.nih.gov/pubmed/35808643 http://dx.doi.org/10.3390/polym14132597 |
work_keys_str_mv | AT phutthimethakullalitsuda partialreplacementofmunicipalincineratedbottomashandpetpelletsasfineaggregateincementmortars AT supakatanuta partialreplacementofmunicipalincineratedbottomashandpetpelletsasfineaggregateincementmortars |