Cargando…

Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars

The objective of this study was to examine the optimal mixing ratio of municipal incinerated bottom ash (MIBA) and PET pellets used as a partial replacement of fine aggregates in the manufacture of cement mortars. As a partial replacement for sand, 15 mortar specimens were prepared by mixing 0%, 10%...

Descripción completa

Detalles Bibliográficos
Autores principales: Phutthimethakul, Lalitsuda, Supakata, Nuta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9269149/
https://www.ncbi.nlm.nih.gov/pubmed/35808643
http://dx.doi.org/10.3390/polym14132597
_version_ 1784744162380218368
author Phutthimethakul, Lalitsuda
Supakata, Nuta
author_facet Phutthimethakul, Lalitsuda
Supakata, Nuta
author_sort Phutthimethakul, Lalitsuda
collection PubMed
description The objective of this study was to examine the optimal mixing ratio of municipal incinerated bottom ash (MIBA) and PET pellets used as a partial replacement of fine aggregates in the manufacture of cement mortars. As a partial replacement for sand, 15 mortar specimens were prepared by mixing 0%, 10%, 20%, 30%, and 40% municipal incinerated bottom ash (MIBA) (A) and 0%, 10%, and 20% PET pellets (P) in 5 cm × 5 cm × 5 cm cube molds. The cement/aggregate ratio was 1:3, and the water/cement ratio was 0.5 for all specimens. The results showed that the compressive strength of cement mortars decreased when increasing the amount of MIBA and PET pellets. The mortar specimens with 10% PET pellets achieved the highest compressive strength (49.53 MPa), whereas the mortar specimens with 40% MIBA and 20% PET pellets achieved the lowest compressive strength (24.44 MPa). Based on this finding, replacing 10% and 20% sand in cement mortar with only MIBA or only PET pellets could result in compressive strengths ranging from 46.00 MPa to 49.53 MPa.
format Online
Article
Text
id pubmed-9269149
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92691492022-07-09 Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars Phutthimethakul, Lalitsuda Supakata, Nuta Polymers (Basel) Article The objective of this study was to examine the optimal mixing ratio of municipal incinerated bottom ash (MIBA) and PET pellets used as a partial replacement of fine aggregates in the manufacture of cement mortars. As a partial replacement for sand, 15 mortar specimens were prepared by mixing 0%, 10%, 20%, 30%, and 40% municipal incinerated bottom ash (MIBA) (A) and 0%, 10%, and 20% PET pellets (P) in 5 cm × 5 cm × 5 cm cube molds. The cement/aggregate ratio was 1:3, and the water/cement ratio was 0.5 for all specimens. The results showed that the compressive strength of cement mortars decreased when increasing the amount of MIBA and PET pellets. The mortar specimens with 10% PET pellets achieved the highest compressive strength (49.53 MPa), whereas the mortar specimens with 40% MIBA and 20% PET pellets achieved the lowest compressive strength (24.44 MPa). Based on this finding, replacing 10% and 20% sand in cement mortar with only MIBA or only PET pellets could result in compressive strengths ranging from 46.00 MPa to 49.53 MPa. MDPI 2022-06-27 /pmc/articles/PMC9269149/ /pubmed/35808643 http://dx.doi.org/10.3390/polym14132597 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Phutthimethakul, Lalitsuda
Supakata, Nuta
Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars
title Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars
title_full Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars
title_fullStr Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars
title_full_unstemmed Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars
title_short Partial Replacement of Municipal Incinerated Bottom Ash and PET Pellets as Fine Aggregate in Cement Mortars
title_sort partial replacement of municipal incinerated bottom ash and pet pellets as fine aggregate in cement mortars
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9269149/
https://www.ncbi.nlm.nih.gov/pubmed/35808643
http://dx.doi.org/10.3390/polym14132597
work_keys_str_mv AT phutthimethakullalitsuda partialreplacementofmunicipalincineratedbottomashandpetpelletsasfineaggregateincementmortars
AT supakatanuta partialreplacementofmunicipalincineratedbottomashandpetpelletsasfineaggregateincementmortars