Blended Polymer Dry Electrodes for Reliable Electrocardiogram and Electromyogram Measurements and Their Eco-Friendly Disposal Led by Degradability in Hot Water
To increase the human lifespan, healthcare monitoring devices that diagnose diseases and check body conditions have attracted considerable interest. Commercial AgCl-based wet electrodes with the advantages of high conductivity and strong adaptability to human skin are considered the most frequently...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9269162/ https://www.ncbi.nlm.nih.gov/pubmed/35808632 http://dx.doi.org/10.3390/polym14132586 |
_version_ | 1784744165689524224 |
---|---|
author | Lee, Dong Hyun Lee, Eun Kwang Kim, Chae Hyun Yun, Hyung Joong Kim, Young-Joon Yoo, Hocheon |
author_facet | Lee, Dong Hyun Lee, Eun Kwang Kim, Chae Hyun Yun, Hyung Joong Kim, Young-Joon Yoo, Hocheon |
author_sort | Lee, Dong Hyun |
collection | PubMed |
description | To increase the human lifespan, healthcare monitoring devices that diagnose diseases and check body conditions have attracted considerable interest. Commercial AgCl-based wet electrodes with the advantages of high conductivity and strong adaptability to human skin are considered the most frequently used electrode material for healthcare monitoring. However, commercial AgCl-based wet electrodes, when exposed for a long period, cause an evaporation of organic solvents, which could reduce the signal-to-noise ratio of biosignals and stimulate human skin. In this context, we demonstrate a dry electrode for a poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS)-based blended polymer electrode using a combination of PEDOT:PSS, waterborne polyurethane (WPU) and ethylene glycol (EG) that could be reused for a long period of time to detect electrocardiography (ECG) and electromyography (EMG). Both ECG and EMG are reliably detected by the wireless real-time monitoring system. In particular, the proposed dry electrode detects biosignals without deterioration for over 2 weeks. Additionally, a double layer of a polyimide (PI) substrate and fluorinated polymer CYTOP induces the strong waterproof characteristics of external liquids for the proposed dry electrodes, having a low surface energy of 14.49 mN/m. In addition, the proposed electrode has excellent degradability in water; it dissolves in hot water at 60 °C. |
format | Online Article Text |
id | pubmed-9269162 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-92691622022-07-09 Blended Polymer Dry Electrodes for Reliable Electrocardiogram and Electromyogram Measurements and Their Eco-Friendly Disposal Led by Degradability in Hot Water Lee, Dong Hyun Lee, Eun Kwang Kim, Chae Hyun Yun, Hyung Joong Kim, Young-Joon Yoo, Hocheon Polymers (Basel) Article To increase the human lifespan, healthcare monitoring devices that diagnose diseases and check body conditions have attracted considerable interest. Commercial AgCl-based wet electrodes with the advantages of high conductivity and strong adaptability to human skin are considered the most frequently used electrode material for healthcare monitoring. However, commercial AgCl-based wet electrodes, when exposed for a long period, cause an evaporation of organic solvents, which could reduce the signal-to-noise ratio of biosignals and stimulate human skin. In this context, we demonstrate a dry electrode for a poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS)-based blended polymer electrode using a combination of PEDOT:PSS, waterborne polyurethane (WPU) and ethylene glycol (EG) that could be reused for a long period of time to detect electrocardiography (ECG) and electromyography (EMG). Both ECG and EMG are reliably detected by the wireless real-time monitoring system. In particular, the proposed dry electrode detects biosignals without deterioration for over 2 weeks. Additionally, a double layer of a polyimide (PI) substrate and fluorinated polymer CYTOP induces the strong waterproof characteristics of external liquids for the proposed dry electrodes, having a low surface energy of 14.49 mN/m. In addition, the proposed electrode has excellent degradability in water; it dissolves in hot water at 60 °C. MDPI 2022-06-26 /pmc/articles/PMC9269162/ /pubmed/35808632 http://dx.doi.org/10.3390/polym14132586 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lee, Dong Hyun Lee, Eun Kwang Kim, Chae Hyun Yun, Hyung Joong Kim, Young-Joon Yoo, Hocheon Blended Polymer Dry Electrodes for Reliable Electrocardiogram and Electromyogram Measurements and Their Eco-Friendly Disposal Led by Degradability in Hot Water |
title | Blended Polymer Dry Electrodes for Reliable Electrocardiogram and Electromyogram Measurements and Their Eco-Friendly Disposal Led by Degradability in Hot Water |
title_full | Blended Polymer Dry Electrodes for Reliable Electrocardiogram and Electromyogram Measurements and Their Eco-Friendly Disposal Led by Degradability in Hot Water |
title_fullStr | Blended Polymer Dry Electrodes for Reliable Electrocardiogram and Electromyogram Measurements and Their Eco-Friendly Disposal Led by Degradability in Hot Water |
title_full_unstemmed | Blended Polymer Dry Electrodes for Reliable Electrocardiogram and Electromyogram Measurements and Their Eco-Friendly Disposal Led by Degradability in Hot Water |
title_short | Blended Polymer Dry Electrodes for Reliable Electrocardiogram and Electromyogram Measurements and Their Eco-Friendly Disposal Led by Degradability in Hot Water |
title_sort | blended polymer dry electrodes for reliable electrocardiogram and electromyogram measurements and their eco-friendly disposal led by degradability in hot water |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9269162/ https://www.ncbi.nlm.nih.gov/pubmed/35808632 http://dx.doi.org/10.3390/polym14132586 |
work_keys_str_mv | AT leedonghyun blendedpolymerdryelectrodesforreliableelectrocardiogramandelectromyogrammeasurementsandtheirecofriendlydisposalledbydegradabilityinhotwater AT leeeunkwang blendedpolymerdryelectrodesforreliableelectrocardiogramandelectromyogrammeasurementsandtheirecofriendlydisposalledbydegradabilityinhotwater AT kimchaehyun blendedpolymerdryelectrodesforreliableelectrocardiogramandelectromyogrammeasurementsandtheirecofriendlydisposalledbydegradabilityinhotwater AT yunhyungjoong blendedpolymerdryelectrodesforreliableelectrocardiogramandelectromyogrammeasurementsandtheirecofriendlydisposalledbydegradabilityinhotwater AT kimyoungjoon blendedpolymerdryelectrodesforreliableelectrocardiogramandelectromyogrammeasurementsandtheirecofriendlydisposalledbydegradabilityinhotwater AT yoohocheon blendedpolymerdryelectrodesforreliableelectrocardiogramandelectromyogrammeasurementsandtheirecofriendlydisposalledbydegradabilityinhotwater |