Cargando…

Anisotropy of the ΔE Effect in Ni-Based Magnetoelectric Cantilevers: A Finite Element Method Analysis

In recent investigations of magnetoelectric sensors based on microelectromechanical cantilevers made of TiN/AlN/Ni, a complex eigenfrequency behavior arising from the anisotropic ΔE effect was demonstrated. Within this work, a FEM simulation model based on this material system is presented to allow...

Descripción completa

Detalles Bibliográficos
Autores principales: Hähnlein, Bernd, Sagar, Neha, Honig, Hauke, Krischok, Stefan, Tonisch, Katja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9269756/
https://www.ncbi.nlm.nih.gov/pubmed/35808450
http://dx.doi.org/10.3390/s22134958
_version_ 1784744299111383040
author Hähnlein, Bernd
Sagar, Neha
Honig, Hauke
Krischok, Stefan
Tonisch, Katja
author_facet Hähnlein, Bernd
Sagar, Neha
Honig, Hauke
Krischok, Stefan
Tonisch, Katja
author_sort Hähnlein, Bernd
collection PubMed
description In recent investigations of magnetoelectric sensors based on microelectromechanical cantilevers made of TiN/AlN/Ni, a complex eigenfrequency behavior arising from the anisotropic ΔE effect was demonstrated. Within this work, a FEM simulation model based on this material system is presented to allow an investigation of the vibrational properties of cantilever-based sensors derived from magnetocrystalline anisotropy while avoiding other anisotropic contributions. Using the magnetocrystalline ΔE effect, a magnetic hardening of Nickel is demonstrated for the (110) as well as the (111) orientation. The sensitivity is extracted from the field-dependent eigenfrequency curves. It is found, that the transitions of the individual magnetic domain states in the magnetization process are the dominant influencing factor on the sensitivity for all crystal orientations. It is shown, that Nickel layers in the sensor aligned along the medium or hard axis yield a higher sensitivity than layers along the easy axis. The peak sensitivity was determined to 41.3 T(−1) for (110) in-plane-oriented Nickel at a magnetic bias flux of 1.78 mT. The results achieved by FEM simulations are compared to the results calculated by the Euler–Bernoulli theory.
format Online
Article
Text
id pubmed-9269756
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92697562022-07-09 Anisotropy of the ΔE Effect in Ni-Based Magnetoelectric Cantilevers: A Finite Element Method Analysis Hähnlein, Bernd Sagar, Neha Honig, Hauke Krischok, Stefan Tonisch, Katja Sensors (Basel) Article In recent investigations of magnetoelectric sensors based on microelectromechanical cantilevers made of TiN/AlN/Ni, a complex eigenfrequency behavior arising from the anisotropic ΔE effect was demonstrated. Within this work, a FEM simulation model based on this material system is presented to allow an investigation of the vibrational properties of cantilever-based sensors derived from magnetocrystalline anisotropy while avoiding other anisotropic contributions. Using the magnetocrystalline ΔE effect, a magnetic hardening of Nickel is demonstrated for the (110) as well as the (111) orientation. The sensitivity is extracted from the field-dependent eigenfrequency curves. It is found, that the transitions of the individual magnetic domain states in the magnetization process are the dominant influencing factor on the sensitivity for all crystal orientations. It is shown, that Nickel layers in the sensor aligned along the medium or hard axis yield a higher sensitivity than layers along the easy axis. The peak sensitivity was determined to 41.3 T(−1) for (110) in-plane-oriented Nickel at a magnetic bias flux of 1.78 mT. The results achieved by FEM simulations are compared to the results calculated by the Euler–Bernoulli theory. MDPI 2022-06-30 /pmc/articles/PMC9269756/ /pubmed/35808450 http://dx.doi.org/10.3390/s22134958 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hähnlein, Bernd
Sagar, Neha
Honig, Hauke
Krischok, Stefan
Tonisch, Katja
Anisotropy of the ΔE Effect in Ni-Based Magnetoelectric Cantilevers: A Finite Element Method Analysis
title Anisotropy of the ΔE Effect in Ni-Based Magnetoelectric Cantilevers: A Finite Element Method Analysis
title_full Anisotropy of the ΔE Effect in Ni-Based Magnetoelectric Cantilevers: A Finite Element Method Analysis
title_fullStr Anisotropy of the ΔE Effect in Ni-Based Magnetoelectric Cantilevers: A Finite Element Method Analysis
title_full_unstemmed Anisotropy of the ΔE Effect in Ni-Based Magnetoelectric Cantilevers: A Finite Element Method Analysis
title_short Anisotropy of the ΔE Effect in Ni-Based Magnetoelectric Cantilevers: A Finite Element Method Analysis
title_sort anisotropy of the δe effect in ni-based magnetoelectric cantilevers: a finite element method analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9269756/
https://www.ncbi.nlm.nih.gov/pubmed/35808450
http://dx.doi.org/10.3390/s22134958
work_keys_str_mv AT hahnleinbernd anisotropyofthedeeffectinnibasedmagnetoelectriccantileversafiniteelementmethodanalysis
AT sagarneha anisotropyofthedeeffectinnibasedmagnetoelectriccantileversafiniteelementmethodanalysis
AT honighauke anisotropyofthedeeffectinnibasedmagnetoelectriccantileversafiniteelementmethodanalysis
AT krischokstefan anisotropyofthedeeffectinnibasedmagnetoelectriccantileversafiniteelementmethodanalysis
AT tonischkatja anisotropyofthedeeffectinnibasedmagnetoelectriccantileversafiniteelementmethodanalysis