Cargando…
Setting Mechanical Insufflation-Exsufflation (MI-E) Pressures for Amyotrophic Lateral Sclerosis (ALS) Patients to Improve Atelectasis and Reduce Risk of Pneumothorax: A Case Report
Mechanical insufflation-exsufflation (MI-E) has been used to supplement the ability to cough and expel pulmonary secretions in patients with neuromuscular disease who have a reduced ability to cough. The manufacturer's guidelines for MI-E recommend a setting of inspiratory pressure of +40 cmH(2...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9270190/ https://www.ncbi.nlm.nih.gov/pubmed/35812619 http://dx.doi.org/10.7759/cureus.25786 |
_version_ | 1784744406436282368 |
---|---|
author | Funo, Keiichi Negishi, Yuri Akamine, Chika Takeuchi, Ryoko Uzawa, Yoshihiro |
author_facet | Funo, Keiichi Negishi, Yuri Akamine, Chika Takeuchi, Ryoko Uzawa, Yoshihiro |
author_sort | Funo, Keiichi |
collection | PubMed |
description | Mechanical insufflation-exsufflation (MI-E) has been used to supplement the ability to cough and expel pulmonary secretions in patients with neuromuscular disease who have a reduced ability to cough. The manufacturer's guidelines for MI-E recommend a setting of inspiratory pressure of +40 cmH(2)O and expiratory pressure of -40 cmH(2)O. However, patients with small stature and restricted ventilatory impairment are prone to pneumothorax, so the manufacturer's recommendations are not used as is, and should be adjusted for the physical and pulmonary characteristics of each patient. Here, we report a case in which MI-E was used for an amyotrophic lateral sclerosis (ALS) patient with short height, low BMI, and restricted lung capacity at inspiratory and expiratory pressures lower than the manufacturer's recommendations. In adjusting MI-E pressure, physical observations such as chest auscultation, visual chest dilation, and observation of secretion movement toward the tracheal tube were performed to avoid unnecessary pressure. As a result, the pressure level set was lower than the manufacturer's recommendation (25 cmH(2)O) but sufficient to improve atelectasis and no pneumothorax occurred. The method we practiced in this study is feasible in any clinical setting. We also believe that MI-E, when performed in conjunction with treatment response observation, can be expected to improve at lower pressures than generally recommended, thereby reducing the risk of lung injury and providing safer treatment. |
format | Online Article Text |
id | pubmed-9270190 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-92701902022-07-09 Setting Mechanical Insufflation-Exsufflation (MI-E) Pressures for Amyotrophic Lateral Sclerosis (ALS) Patients to Improve Atelectasis and Reduce Risk of Pneumothorax: A Case Report Funo, Keiichi Negishi, Yuri Akamine, Chika Takeuchi, Ryoko Uzawa, Yoshihiro Cureus Neurology Mechanical insufflation-exsufflation (MI-E) has been used to supplement the ability to cough and expel pulmonary secretions in patients with neuromuscular disease who have a reduced ability to cough. The manufacturer's guidelines for MI-E recommend a setting of inspiratory pressure of +40 cmH(2)O and expiratory pressure of -40 cmH(2)O. However, patients with small stature and restricted ventilatory impairment are prone to pneumothorax, so the manufacturer's recommendations are not used as is, and should be adjusted for the physical and pulmonary characteristics of each patient. Here, we report a case in which MI-E was used for an amyotrophic lateral sclerosis (ALS) patient with short height, low BMI, and restricted lung capacity at inspiratory and expiratory pressures lower than the manufacturer's recommendations. In adjusting MI-E pressure, physical observations such as chest auscultation, visual chest dilation, and observation of secretion movement toward the tracheal tube were performed to avoid unnecessary pressure. As a result, the pressure level set was lower than the manufacturer's recommendation (25 cmH(2)O) but sufficient to improve atelectasis and no pneumothorax occurred. The method we practiced in this study is feasible in any clinical setting. We also believe that MI-E, when performed in conjunction with treatment response observation, can be expected to improve at lower pressures than generally recommended, thereby reducing the risk of lung injury and providing safer treatment. Cureus 2022-06-09 /pmc/articles/PMC9270190/ /pubmed/35812619 http://dx.doi.org/10.7759/cureus.25786 Text en Copyright © 2022, Funo et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Neurology Funo, Keiichi Negishi, Yuri Akamine, Chika Takeuchi, Ryoko Uzawa, Yoshihiro Setting Mechanical Insufflation-Exsufflation (MI-E) Pressures for Amyotrophic Lateral Sclerosis (ALS) Patients to Improve Atelectasis and Reduce Risk of Pneumothorax: A Case Report |
title | Setting Mechanical Insufflation-Exsufflation (MI-E) Pressures for Amyotrophic Lateral Sclerosis (ALS) Patients to Improve Atelectasis and Reduce Risk of Pneumothorax: A Case Report |
title_full | Setting Mechanical Insufflation-Exsufflation (MI-E) Pressures for Amyotrophic Lateral Sclerosis (ALS) Patients to Improve Atelectasis and Reduce Risk of Pneumothorax: A Case Report |
title_fullStr | Setting Mechanical Insufflation-Exsufflation (MI-E) Pressures for Amyotrophic Lateral Sclerosis (ALS) Patients to Improve Atelectasis and Reduce Risk of Pneumothorax: A Case Report |
title_full_unstemmed | Setting Mechanical Insufflation-Exsufflation (MI-E) Pressures for Amyotrophic Lateral Sclerosis (ALS) Patients to Improve Atelectasis and Reduce Risk of Pneumothorax: A Case Report |
title_short | Setting Mechanical Insufflation-Exsufflation (MI-E) Pressures for Amyotrophic Lateral Sclerosis (ALS) Patients to Improve Atelectasis and Reduce Risk of Pneumothorax: A Case Report |
title_sort | setting mechanical insufflation-exsufflation (mi-e) pressures for amyotrophic lateral sclerosis (als) patients to improve atelectasis and reduce risk of pneumothorax: a case report |
topic | Neurology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9270190/ https://www.ncbi.nlm.nih.gov/pubmed/35812619 http://dx.doi.org/10.7759/cureus.25786 |
work_keys_str_mv | AT funokeiichi settingmechanicalinsufflationexsufflationmiepressuresforamyotrophiclateralsclerosisalspatientstoimproveatelectasisandreduceriskofpneumothoraxacasereport AT negishiyuri settingmechanicalinsufflationexsufflationmiepressuresforamyotrophiclateralsclerosisalspatientstoimproveatelectasisandreduceriskofpneumothoraxacasereport AT akaminechika settingmechanicalinsufflationexsufflationmiepressuresforamyotrophiclateralsclerosisalspatientstoimproveatelectasisandreduceriskofpneumothoraxacasereport AT takeuchiryoko settingmechanicalinsufflationexsufflationmiepressuresforamyotrophiclateralsclerosisalspatientstoimproveatelectasisandreduceriskofpneumothoraxacasereport AT uzawayoshihiro settingmechanicalinsufflationexsufflationmiepressuresforamyotrophiclateralsclerosisalspatientstoimproveatelectasisandreduceriskofpneumothoraxacasereport |