Cargando…
Parameters associated with unsuccessful pessary fitting for pelvic organ prolapse up to three months follow-up: a systematic review and meta-analysis
OBJECTIVES: To clarify which parameters are associated with unsuccessful pessary fitting for pelvic organ prolapse (POP) at up to 3 months follow-up. METHODS: Embase, PubMed and Cochrane CENTRAL library were searched in May 2020. Inclusion criteria were: (1) pessary fitting attempted in women with s...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9270314/ https://www.ncbi.nlm.nih.gov/pubmed/35037973 http://dx.doi.org/10.1007/s00192-021-05015-2 |
_version_ | 1784744436471693312 |
---|---|
author | Manzini, Claudia Morsinkhof, Lisan M. van der Vaart, C. Huub Withagen, Mariëlla I. J. Grob, Anique T. M. |
author_facet | Manzini, Claudia Morsinkhof, Lisan M. van der Vaart, C. Huub Withagen, Mariëlla I. J. Grob, Anique T. M. |
author_sort | Manzini, Claudia |
collection | PubMed |
description | OBJECTIVES: To clarify which parameters are associated with unsuccessful pessary fitting for pelvic organ prolapse (POP) at up to 3 months follow-up. METHODS: Embase, PubMed and Cochrane CENTRAL library were searched in May 2020. Inclusion criteria were: (1) pessary fitting attempted in women with symptomatic POP; (2) pessary fitting success among the study outcomes with a maximal follow-up of 3 months; (3) baseline parameters compared between successful and unsuccessful group. A meta-analysis was performed using the random effects model. MAIN RESULTS: Twenty-four studies were included in the meta-analysis. Parameters associated with unsuccessful pessary fitting were: age (OR 0.70, 95% CI 0.56–0.86); BMI (OR 1.35, 95% CI 1.08–1.70); menopause (OR 0.65 95% CI 0.47–0.88); de novo stress urinary incontinence (OR 5.59, 95% CI 2.24–13.99); prior surgery, i.e. hysterectomy (OR 1.88, 95% CI 1.48–2.40), POP surgery (OR 2.13, 95% CI 1.34–3.38), pelvic surgery (OR 1.81, 05% CI 1.01–3.26) and incontinence surgery (OR 1.87, 95% CI 1.08–3.25); Colorectal-Anal Distress Inventory-8 scores (OR 1.92, 95% CI 1.22–3.02); solitary predominant posterior compartment POP (OR 1.59, 95% CI 1.08–2.35); total vaginal length (OR 0.56, 95% CI 0.32–0.97); wide introitus (OR 4.85, 95% CI 1.60–14.68); levator ani avulsion (OR 2.47, 95% CI 1.35–4.53) and hiatal area on maximum Valsalva (OR 1.89, 95% CI 1.27–2.80). CONCLUSION: During counselling for pessary treatment a higher risk of failure due to the aforementioned parameters should be discussed and modifiable parameters should be addressed. More research is needed on the association between anatomical parameters and specific reasons for unsuccessful pessary fitting. |
format | Online Article Text |
id | pubmed-9270314 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-92703142022-07-10 Parameters associated with unsuccessful pessary fitting for pelvic organ prolapse up to three months follow-up: a systematic review and meta-analysis Manzini, Claudia Morsinkhof, Lisan M. van der Vaart, C. Huub Withagen, Mariëlla I. J. Grob, Anique T. M. Int Urogynecol J Review Article OBJECTIVES: To clarify which parameters are associated with unsuccessful pessary fitting for pelvic organ prolapse (POP) at up to 3 months follow-up. METHODS: Embase, PubMed and Cochrane CENTRAL library were searched in May 2020. Inclusion criteria were: (1) pessary fitting attempted in women with symptomatic POP; (2) pessary fitting success among the study outcomes with a maximal follow-up of 3 months; (3) baseline parameters compared between successful and unsuccessful group. A meta-analysis was performed using the random effects model. MAIN RESULTS: Twenty-four studies were included in the meta-analysis. Parameters associated with unsuccessful pessary fitting were: age (OR 0.70, 95% CI 0.56–0.86); BMI (OR 1.35, 95% CI 1.08–1.70); menopause (OR 0.65 95% CI 0.47–0.88); de novo stress urinary incontinence (OR 5.59, 95% CI 2.24–13.99); prior surgery, i.e. hysterectomy (OR 1.88, 95% CI 1.48–2.40), POP surgery (OR 2.13, 95% CI 1.34–3.38), pelvic surgery (OR 1.81, 05% CI 1.01–3.26) and incontinence surgery (OR 1.87, 95% CI 1.08–3.25); Colorectal-Anal Distress Inventory-8 scores (OR 1.92, 95% CI 1.22–3.02); solitary predominant posterior compartment POP (OR 1.59, 95% CI 1.08–2.35); total vaginal length (OR 0.56, 95% CI 0.32–0.97); wide introitus (OR 4.85, 95% CI 1.60–14.68); levator ani avulsion (OR 2.47, 95% CI 1.35–4.53) and hiatal area on maximum Valsalva (OR 1.89, 95% CI 1.27–2.80). CONCLUSION: During counselling for pessary treatment a higher risk of failure due to the aforementioned parameters should be discussed and modifiable parameters should be addressed. More research is needed on the association between anatomical parameters and specific reasons for unsuccessful pessary fitting. Springer International Publishing 2022-01-17 2022 /pmc/articles/PMC9270314/ /pubmed/35037973 http://dx.doi.org/10.1007/s00192-021-05015-2 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Review Article Manzini, Claudia Morsinkhof, Lisan M. van der Vaart, C. Huub Withagen, Mariëlla I. J. Grob, Anique T. M. Parameters associated with unsuccessful pessary fitting for pelvic organ prolapse up to three months follow-up: a systematic review and meta-analysis |
title | Parameters associated with unsuccessful pessary fitting for pelvic organ prolapse up to three months follow-up: a systematic review and meta-analysis |
title_full | Parameters associated with unsuccessful pessary fitting for pelvic organ prolapse up to three months follow-up: a systematic review and meta-analysis |
title_fullStr | Parameters associated with unsuccessful pessary fitting for pelvic organ prolapse up to three months follow-up: a systematic review and meta-analysis |
title_full_unstemmed | Parameters associated with unsuccessful pessary fitting for pelvic organ prolapse up to three months follow-up: a systematic review and meta-analysis |
title_short | Parameters associated with unsuccessful pessary fitting for pelvic organ prolapse up to three months follow-up: a systematic review and meta-analysis |
title_sort | parameters associated with unsuccessful pessary fitting for pelvic organ prolapse up to three months follow-up: a systematic review and meta-analysis |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9270314/ https://www.ncbi.nlm.nih.gov/pubmed/35037973 http://dx.doi.org/10.1007/s00192-021-05015-2 |
work_keys_str_mv | AT manziniclaudia parametersassociatedwithunsuccessfulpessaryfittingforpelvicorganprolapseuptothreemonthsfollowupasystematicreviewandmetaanalysis AT morsinkhoflisanm parametersassociatedwithunsuccessfulpessaryfittingforpelvicorganprolapseuptothreemonthsfollowupasystematicreviewandmetaanalysis AT vandervaartchuub parametersassociatedwithunsuccessfulpessaryfittingforpelvicorganprolapseuptothreemonthsfollowupasystematicreviewandmetaanalysis AT withagenmariellaij parametersassociatedwithunsuccessfulpessaryfittingforpelvicorganprolapseuptothreemonthsfollowupasystematicreviewandmetaanalysis AT grobaniquetm parametersassociatedwithunsuccessfulpessaryfittingforpelvicorganprolapseuptothreemonthsfollowupasystematicreviewandmetaanalysis |