Cargando…
Improved geometric accuracy of whole body diffusion-weighted imaging at 1.5T and 3T using reverse polarity gradients
Whole body diffusion-weighted imaging (WB-DWI) is increasingly used in oncological applications, but suffers from misalignments due to susceptibility-induced geometric distortion. As such, DWI and structural images acquired in the same scan session are not geometrically aligned, leading to difficult...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9270424/ https://www.ncbi.nlm.nih.gov/pubmed/35804034 http://dx.doi.org/10.1038/s41598-022-15872-6 |
_version_ | 1784744465735352320 |
---|---|
author | Sjöholm, T. Kullberg, J. Strand, R. Engström, M. Ahlström, H. Malmberg, F. |
author_facet | Sjöholm, T. Kullberg, J. Strand, R. Engström, M. Ahlström, H. Malmberg, F. |
author_sort | Sjöholm, T. |
collection | PubMed |
description | Whole body diffusion-weighted imaging (WB-DWI) is increasingly used in oncological applications, but suffers from misalignments due to susceptibility-induced geometric distortion. As such, DWI and structural images acquired in the same scan session are not geometrically aligned, leading to difficulties in e.g. lesion detection and segmentation. In this work we assess the performance of the reverse polarity gradient (RPG) method for correction of WB-DWI geometric distortion. Multi-station DWI and structural magnetic resonance imaging (MRI) data of healthy controls were acquired at 1.5T (n = 20) and 3T (n = 20). DWI data was distortion corrected using the RPG method based on b = 0 s/mm(2) (b0) and b = 50 s/mm(2) (b50) DWI acquisitions. Mutual information (MI) between low b-value DWI and structural data increased with distortion correction (P < 0.05), while improvements in region of interest (ROI) based similarity metrics, comparing the position of incidental findings on DWI and structural data, were location dependent. Small numerical differences between non-corrected and distortion corrected apparent diffusion coefficient (ADC) values were measured. Visually, the distortion correction improved spine alignment at station borders, but introduced registration-based artefacts mainly for the spleen and kidneys. Overall, the RPG distortion correction gave an improved geometric accuracy for WB-DWI data acquired at 1.5T and 3T. The b0- and b50-based distortion corrections had a very similar performance. |
format | Online Article Text |
id | pubmed-9270424 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-92704242022-07-10 Improved geometric accuracy of whole body diffusion-weighted imaging at 1.5T and 3T using reverse polarity gradients Sjöholm, T. Kullberg, J. Strand, R. Engström, M. Ahlström, H. Malmberg, F. Sci Rep Article Whole body diffusion-weighted imaging (WB-DWI) is increasingly used in oncological applications, but suffers from misalignments due to susceptibility-induced geometric distortion. As such, DWI and structural images acquired in the same scan session are not geometrically aligned, leading to difficulties in e.g. lesion detection and segmentation. In this work we assess the performance of the reverse polarity gradient (RPG) method for correction of WB-DWI geometric distortion. Multi-station DWI and structural magnetic resonance imaging (MRI) data of healthy controls were acquired at 1.5T (n = 20) and 3T (n = 20). DWI data was distortion corrected using the RPG method based on b = 0 s/mm(2) (b0) and b = 50 s/mm(2) (b50) DWI acquisitions. Mutual information (MI) between low b-value DWI and structural data increased with distortion correction (P < 0.05), while improvements in region of interest (ROI) based similarity metrics, comparing the position of incidental findings on DWI and structural data, were location dependent. Small numerical differences between non-corrected and distortion corrected apparent diffusion coefficient (ADC) values were measured. Visually, the distortion correction improved spine alignment at station borders, but introduced registration-based artefacts mainly for the spleen and kidneys. Overall, the RPG distortion correction gave an improved geometric accuracy for WB-DWI data acquired at 1.5T and 3T. The b0- and b50-based distortion corrections had a very similar performance. Nature Publishing Group UK 2022-07-08 /pmc/articles/PMC9270424/ /pubmed/35804034 http://dx.doi.org/10.1038/s41598-022-15872-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Sjöholm, T. Kullberg, J. Strand, R. Engström, M. Ahlström, H. Malmberg, F. Improved geometric accuracy of whole body diffusion-weighted imaging at 1.5T and 3T using reverse polarity gradients |
title | Improved geometric accuracy of whole body diffusion-weighted imaging at 1.5T and 3T using reverse polarity gradients |
title_full | Improved geometric accuracy of whole body diffusion-weighted imaging at 1.5T and 3T using reverse polarity gradients |
title_fullStr | Improved geometric accuracy of whole body diffusion-weighted imaging at 1.5T and 3T using reverse polarity gradients |
title_full_unstemmed | Improved geometric accuracy of whole body diffusion-weighted imaging at 1.5T and 3T using reverse polarity gradients |
title_short | Improved geometric accuracy of whole body diffusion-weighted imaging at 1.5T and 3T using reverse polarity gradients |
title_sort | improved geometric accuracy of whole body diffusion-weighted imaging at 1.5t and 3t using reverse polarity gradients |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9270424/ https://www.ncbi.nlm.nih.gov/pubmed/35804034 http://dx.doi.org/10.1038/s41598-022-15872-6 |
work_keys_str_mv | AT sjoholmt improvedgeometricaccuracyofwholebodydiffusionweightedimagingat15tand3tusingreversepolaritygradients AT kullbergj improvedgeometricaccuracyofwholebodydiffusionweightedimagingat15tand3tusingreversepolaritygradients AT strandr improvedgeometricaccuracyofwholebodydiffusionweightedimagingat15tand3tusingreversepolaritygradients AT engstromm improvedgeometricaccuracyofwholebodydiffusionweightedimagingat15tand3tusingreversepolaritygradients AT ahlstromh improvedgeometricaccuracyofwholebodydiffusionweightedimagingat15tand3tusingreversepolaritygradients AT malmbergf improvedgeometricaccuracyofwholebodydiffusionweightedimagingat15tand3tusingreversepolaritygradients |