Cargando…
URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome
BACKGROUND: The HEART score is a validated risk stratification tool for chest pain patients presenting to the emergency department and was recently investigated for implementation in a pre-hospital setting. Fingerstick (capillary blood) point-of-care (POC) troponin testing enables quick measurements...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bohn Stafleu van Loghum
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9270546/ https://www.ncbi.nlm.nih.gov/pubmed/34817832 http://dx.doi.org/10.1007/s12471-021-01646-8 |
_version_ | 1784744487493304320 |
---|---|
author | Koper, L. H. Frenk, L. D. S. Meeder, J. G. van Osch, F. H. M. Bruinen, A. L. Janssen, M. J. W. van ’t Hof, A. W. J. Rahel, B. M. |
author_facet | Koper, L. H. Frenk, L. D. S. Meeder, J. G. van Osch, F. H. M. Bruinen, A. L. Janssen, M. J. W. van ’t Hof, A. W. J. Rahel, B. M. |
author_sort | Koper, L. H. |
collection | PubMed |
description | BACKGROUND: The HEART score is a validated risk stratification tool for chest pain patients presenting to the emergency department and was recently investigated for implementation in a pre-hospital setting. Fingerstick (capillary blood) point-of-care (POC) troponin testing enables quick measurements outside the hospital and seems easier to implement than the current venous blood sampling techniques. This study investigates the diagnostic accuracy of the modified HEART score, integrating fingerstick POC troponin testing, in ruling out acute coronary syndrome (ACS). METHODS: The data of 96 patients with chest pain, included in a study investigating a novel POC troponin device under development at the cardiac emergency department, were analysed retrospectively. Based on the patients’ admission data and capillary POC high-sensitivity troponin I (hs-cTnI) results, the modified HEART score was determined. The outcome measure, for evaluating the diagnostic accuracy of the modified HEART score, was the occurrence of ACS. RESULTS: Of the total study population, 33 patients (34%) were diagnosed with ACS. Seventeen patients (18%) were classified as low risk (0–3 points) and one patient (6%) in this group was diagnosed with ACS. The sensitivity and negative predictive value of the modified HEART score was 97.0 and 97.6%, respectively. CONCLUSION: The modified HEART score, integrating capillary POC hs-cTnI results, is a promising tool for ruling out ACS in patients with chest pain presenting to the cardiac emergency department. These results encourage prospective investigation into the integration of fingerstick POC troponin testing in the modified HEART score in a pre-hospital setting. SUPPLEMENTARY INFORMATION: The online version of this article (10.1007/s12471-021-01646-8) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-9270546 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Bohn Stafleu van Loghum |
record_format | MEDLINE/PubMed |
spelling | pubmed-92705462022-07-10 URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome Koper, L. H. Frenk, L. D. S. Meeder, J. G. van Osch, F. H. M. Bruinen, A. L. Janssen, M. J. W. van ’t Hof, A. W. J. Rahel, B. M. Neth Heart J Original Article BACKGROUND: The HEART score is a validated risk stratification tool for chest pain patients presenting to the emergency department and was recently investigated for implementation in a pre-hospital setting. Fingerstick (capillary blood) point-of-care (POC) troponin testing enables quick measurements outside the hospital and seems easier to implement than the current venous blood sampling techniques. This study investigates the diagnostic accuracy of the modified HEART score, integrating fingerstick POC troponin testing, in ruling out acute coronary syndrome (ACS). METHODS: The data of 96 patients with chest pain, included in a study investigating a novel POC troponin device under development at the cardiac emergency department, were analysed retrospectively. Based on the patients’ admission data and capillary POC high-sensitivity troponin I (hs-cTnI) results, the modified HEART score was determined. The outcome measure, for evaluating the diagnostic accuracy of the modified HEART score, was the occurrence of ACS. RESULTS: Of the total study population, 33 patients (34%) were diagnosed with ACS. Seventeen patients (18%) were classified as low risk (0–3 points) and one patient (6%) in this group was diagnosed with ACS. The sensitivity and negative predictive value of the modified HEART score was 97.0 and 97.6%, respectively. CONCLUSION: The modified HEART score, integrating capillary POC hs-cTnI results, is a promising tool for ruling out ACS in patients with chest pain presenting to the cardiac emergency department. These results encourage prospective investigation into the integration of fingerstick POC troponin testing in the modified HEART score in a pre-hospital setting. SUPPLEMENTARY INFORMATION: The online version of this article (10.1007/s12471-021-01646-8) contains supplementary material, which is available to authorized users. Bohn Stafleu van Loghum 2021-11-24 2022-07 /pmc/articles/PMC9270546/ /pubmed/34817832 http://dx.doi.org/10.1007/s12471-021-01646-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Koper, L. H. Frenk, L. D. S. Meeder, J. G. van Osch, F. H. M. Bruinen, A. L. Janssen, M. J. W. van ’t Hof, A. W. J. Rahel, B. M. URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome |
title | URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome |
title_full | URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome |
title_fullStr | URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome |
title_full_unstemmed | URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome |
title_short | URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome |
title_sort | urgent 1.5: diagnostic accuracy of the modified heart score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9270546/ https://www.ncbi.nlm.nih.gov/pubmed/34817832 http://dx.doi.org/10.1007/s12471-021-01646-8 |
work_keys_str_mv | AT koperlh urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome AT frenklds urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome AT meederjg urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome AT vanoschfhm urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome AT bruinenal urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome AT janssenmjw urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome AT vanthofawj urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome AT rahelbm urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome |