Cargando…

URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome

BACKGROUND: The HEART score is a validated risk stratification tool for chest pain patients presenting to the emergency department and was recently investigated for implementation in a pre-hospital setting. Fingerstick (capillary blood) point-of-care (POC) troponin testing enables quick measurements...

Descripción completa

Detalles Bibliográficos
Autores principales: Koper, L. H., Frenk, L. D. S., Meeder, J. G., van Osch, F. H. M., Bruinen, A. L., Janssen, M. J. W., van ’t Hof, A. W. J., Rahel, B. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bohn Stafleu van Loghum 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9270546/
https://www.ncbi.nlm.nih.gov/pubmed/34817832
http://dx.doi.org/10.1007/s12471-021-01646-8
_version_ 1784744487493304320
author Koper, L. H.
Frenk, L. D. S.
Meeder, J. G.
van Osch, F. H. M.
Bruinen, A. L.
Janssen, M. J. W.
van ’t Hof, A. W. J.
Rahel, B. M.
author_facet Koper, L. H.
Frenk, L. D. S.
Meeder, J. G.
van Osch, F. H. M.
Bruinen, A. L.
Janssen, M. J. W.
van ’t Hof, A. W. J.
Rahel, B. M.
author_sort Koper, L. H.
collection PubMed
description BACKGROUND: The HEART score is a validated risk stratification tool for chest pain patients presenting to the emergency department and was recently investigated for implementation in a pre-hospital setting. Fingerstick (capillary blood) point-of-care (POC) troponin testing enables quick measurements outside the hospital and seems easier to implement than the current venous blood sampling techniques. This study investigates the diagnostic accuracy of the modified HEART score, integrating fingerstick POC troponin testing, in ruling out acute coronary syndrome (ACS). METHODS: The data of 96 patients with chest pain, included in a study investigating a novel POC troponin device under development at the cardiac emergency department, were analysed retrospectively. Based on the patients’ admission data and capillary POC high-sensitivity troponin I (hs-cTnI) results, the modified HEART score was determined. The outcome measure, for evaluating the diagnostic accuracy of the modified HEART score, was the occurrence of ACS. RESULTS: Of the total study population, 33 patients (34%) were diagnosed with ACS. Seventeen patients (18%) were classified as low risk (0–3 points) and one patient (6%) in this group was diagnosed with ACS. The sensitivity and negative predictive value of the modified HEART score was 97.0 and 97.6%, respectively. CONCLUSION: The modified HEART score, integrating capillary POC hs-cTnI results, is a promising tool for ruling out ACS in patients with chest pain presenting to the cardiac emergency department. These results encourage prospective investigation into the integration of fingerstick POC troponin testing in the modified HEART score in a pre-hospital setting. SUPPLEMENTARY INFORMATION: The online version of this article (10.1007/s12471-021-01646-8) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-9270546
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Bohn Stafleu van Loghum
record_format MEDLINE/PubMed
spelling pubmed-92705462022-07-10 URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome Koper, L. H. Frenk, L. D. S. Meeder, J. G. van Osch, F. H. M. Bruinen, A. L. Janssen, M. J. W. van ’t Hof, A. W. J. Rahel, B. M. Neth Heart J Original Article BACKGROUND: The HEART score is a validated risk stratification tool for chest pain patients presenting to the emergency department and was recently investigated for implementation in a pre-hospital setting. Fingerstick (capillary blood) point-of-care (POC) troponin testing enables quick measurements outside the hospital and seems easier to implement than the current venous blood sampling techniques. This study investigates the diagnostic accuracy of the modified HEART score, integrating fingerstick POC troponin testing, in ruling out acute coronary syndrome (ACS). METHODS: The data of 96 patients with chest pain, included in a study investigating a novel POC troponin device under development at the cardiac emergency department, were analysed retrospectively. Based on the patients’ admission data and capillary POC high-sensitivity troponin I (hs-cTnI) results, the modified HEART score was determined. The outcome measure, for evaluating the diagnostic accuracy of the modified HEART score, was the occurrence of ACS. RESULTS: Of the total study population, 33 patients (34%) were diagnosed with ACS. Seventeen patients (18%) were classified as low risk (0–3 points) and one patient (6%) in this group was diagnosed with ACS. The sensitivity and negative predictive value of the modified HEART score was 97.0 and 97.6%, respectively. CONCLUSION: The modified HEART score, integrating capillary POC hs-cTnI results, is a promising tool for ruling out ACS in patients with chest pain presenting to the cardiac emergency department. These results encourage prospective investigation into the integration of fingerstick POC troponin testing in the modified HEART score in a pre-hospital setting. SUPPLEMENTARY INFORMATION: The online version of this article (10.1007/s12471-021-01646-8) contains supplementary material, which is available to authorized users. Bohn Stafleu van Loghum 2021-11-24 2022-07 /pmc/articles/PMC9270546/ /pubmed/34817832 http://dx.doi.org/10.1007/s12471-021-01646-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Koper, L. H.
Frenk, L. D. S.
Meeder, J. G.
van Osch, F. H. M.
Bruinen, A. L.
Janssen, M. J. W.
van ’t Hof, A. W. J.
Rahel, B. M.
URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome
title URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome
title_full URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome
title_fullStr URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome
title_full_unstemmed URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome
title_short URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome
title_sort urgent 1.5: diagnostic accuracy of the modified heart score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9270546/
https://www.ncbi.nlm.nih.gov/pubmed/34817832
http://dx.doi.org/10.1007/s12471-021-01646-8
work_keys_str_mv AT koperlh urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome
AT frenklds urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome
AT meederjg urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome
AT vanoschfhm urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome
AT bruinenal urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome
AT janssenmjw urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome
AT vanthofawj urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome
AT rahelbm urgent15diagnosticaccuracyofthemodifiedheartscorewithfingerstickpointofcaretroponintestinginrulingoutacutecoronarysyndrome