Cargando…

Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively

OBJECTIVES: The aim of this study was to evaluate the impact of changing the sizing strategy in aortic valve replacement using the Perceval sutureless prosthesis on haemodynamic outcomes and postoperative pacemaker implantation. METHODS: Retrospective analysis of patients implanted with the Perceval...

Descripción completa

Detalles Bibliográficos
Autores principales: Szecel, Delphine, Lamberigts, Marie, Rega, Filip, Verbrugghe, Peter, Dubois, Christophe, Meuris, Bart
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9272061/
https://www.ncbi.nlm.nih.gov/pubmed/35689614
http://dx.doi.org/10.1093/icvts/ivac157
_version_ 1784744812811911168
author Szecel, Delphine
Lamberigts, Marie
Rega, Filip
Verbrugghe, Peter
Dubois, Christophe
Meuris, Bart
author_facet Szecel, Delphine
Lamberigts, Marie
Rega, Filip
Verbrugghe, Peter
Dubois, Christophe
Meuris, Bart
author_sort Szecel, Delphine
collection PubMed
description OBJECTIVES: The aim of this study was to evaluate the impact of changing the sizing strategy in aortic valve replacement using the Perceval sutureless prosthesis on haemodynamic outcomes and postoperative pacemaker implantation. METHODS: Retrospective analysis of patients implanted with the Perceval valve between 2007 and 2019 was performed by comparing patients implanted before the modification of sizing strategy (OLD group) and after (NEW group). The outcome parameters evaluated were the implanted prosthesis size, haemodynamical profile and postoperative pacemaker implantation. RESULTS: The entire patient cohort (784 patients) consisted of 52% female patients, with a mean age of 78.53 [standard deviation (SD): 5.8] years and a mean EuroSCORE II of 6.3 (range 0.7–76). In 55.5% of cases, surgery was combined. The NEW cohort had more male patients (54.6% vs 43.4%) (P = 0.002). Mean implanted valve size, corrected for body surface area, was significantly lower in the NEW cohort (13.1, SD: 1.4 vs 13.5, SD: 1.4 mm/m(2), P < 0.001). The 30-day mortality was 3.4%. Peak and mean transvalvular gradients at discharge were significantly lower in the NEW versus OLD groups: 24.4 mmHg (SD: 9.2) versus 28.4 mmHg (SD: 10.3) (P < 0.001) and 13.6 mmHg (SD: 5.3) versus 15.5 mmHg (SD: 6.0) (P < 0.001). The mean effective opening area and the indexed effective opening area, respectively, increased from 1.5 cm(2) (SD: 0.5) and 0.85 cm(2)/m(2) (SD: 0.27) in the OLD group to 1.7 cm(2) (SD: 0.5) and 0.93 cm(2)/m(2) (SD: 0.30) in the NEW group (P < 0.001). No difference was found in paravalvular leakage ≥1/4. Centrovalvular leakage ≥1/4 significantly decreased from 18% to 7.9% (P < 0.001). With the new sizing, the new postoperative pacemaker implantation rate decreased significantly from 11% to 6.1% (P = 0.016). CONCLUSIONS: Correct sizing of sutureless aortic valves is crucial to obtain the best possible haemodynamics and avoid complications.
format Online
Article
Text
id pubmed-9272061
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-92720612022-07-11 Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively Szecel, Delphine Lamberigts, Marie Rega, Filip Verbrugghe, Peter Dubois, Christophe Meuris, Bart Interact Cardiovasc Thorac Surg Adult Cardiac OBJECTIVES: The aim of this study was to evaluate the impact of changing the sizing strategy in aortic valve replacement using the Perceval sutureless prosthesis on haemodynamic outcomes and postoperative pacemaker implantation. METHODS: Retrospective analysis of patients implanted with the Perceval valve between 2007 and 2019 was performed by comparing patients implanted before the modification of sizing strategy (OLD group) and after (NEW group). The outcome parameters evaluated were the implanted prosthesis size, haemodynamical profile and postoperative pacemaker implantation. RESULTS: The entire patient cohort (784 patients) consisted of 52% female patients, with a mean age of 78.53 [standard deviation (SD): 5.8] years and a mean EuroSCORE II of 6.3 (range 0.7–76). In 55.5% of cases, surgery was combined. The NEW cohort had more male patients (54.6% vs 43.4%) (P = 0.002). Mean implanted valve size, corrected for body surface area, was significantly lower in the NEW cohort (13.1, SD: 1.4 vs 13.5, SD: 1.4 mm/m(2), P < 0.001). The 30-day mortality was 3.4%. Peak and mean transvalvular gradients at discharge were significantly lower in the NEW versus OLD groups: 24.4 mmHg (SD: 9.2) versus 28.4 mmHg (SD: 10.3) (P < 0.001) and 13.6 mmHg (SD: 5.3) versus 15.5 mmHg (SD: 6.0) (P < 0.001). The mean effective opening area and the indexed effective opening area, respectively, increased from 1.5 cm(2) (SD: 0.5) and 0.85 cm(2)/m(2) (SD: 0.27) in the OLD group to 1.7 cm(2) (SD: 0.5) and 0.93 cm(2)/m(2) (SD: 0.30) in the NEW group (P < 0.001). No difference was found in paravalvular leakage ≥1/4. Centrovalvular leakage ≥1/4 significantly decreased from 18% to 7.9% (P < 0.001). With the new sizing, the new postoperative pacemaker implantation rate decreased significantly from 11% to 6.1% (P = 0.016). CONCLUSIONS: Correct sizing of sutureless aortic valves is crucial to obtain the best possible haemodynamics and avoid complications. Oxford University Press 2022-06-11 /pmc/articles/PMC9272061/ /pubmed/35689614 http://dx.doi.org/10.1093/icvts/ivac157 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Adult Cardiac
Szecel, Delphine
Lamberigts, Marie
Rega, Filip
Verbrugghe, Peter
Dubois, Christophe
Meuris, Bart
Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively
title Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively
title_full Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively
title_fullStr Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively
title_full_unstemmed Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively
title_short Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively
title_sort avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively
topic Adult Cardiac
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9272061/
https://www.ncbi.nlm.nih.gov/pubmed/35689614
http://dx.doi.org/10.1093/icvts/ivac157
work_keys_str_mv AT szeceldelphine avoidingoversizinginsuturelessvalvesleadstolowertransvalvulargradientsandlesspermanentpacemakerimplantspostoperatively
AT lamberigtsmarie avoidingoversizinginsuturelessvalvesleadstolowertransvalvulargradientsandlesspermanentpacemakerimplantspostoperatively
AT regafilip avoidingoversizinginsuturelessvalvesleadstolowertransvalvulargradientsandlesspermanentpacemakerimplantspostoperatively
AT verbrugghepeter avoidingoversizinginsuturelessvalvesleadstolowertransvalvulargradientsandlesspermanentpacemakerimplantspostoperatively
AT duboischristophe avoidingoversizinginsuturelessvalvesleadstolowertransvalvulargradientsandlesspermanentpacemakerimplantspostoperatively
AT meurisbart avoidingoversizinginsuturelessvalvesleadstolowertransvalvulargradientsandlesspermanentpacemakerimplantspostoperatively