Cargando…

Robot-assisted revision of sacroiliac joint fusion using a triangular titanium implant in an S2-alar-iliac trajectory: illustrative case

BACKGROUND: Sacroiliac joint (SIJ) dysfunction can lead to significant pain and disability, greatly impairing quality of life. Arthrodesis may take up to 1 year to occur, after which revision can be considered. There is a need for highly accurate and reproducible techniques for revision that allow f...

Descripción completa

Detalles Bibliográficos
Autores principales: Triano, Matthew, Fayed, Islam, Sandhu, Faheem A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Association of Neurological Surgeons 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9272365/
https://www.ncbi.nlm.nih.gov/pubmed/35854956
http://dx.doi.org/10.3171/CASE2169
_version_ 1784744859128561664
author Triano, Matthew
Fayed, Islam
Sandhu, Faheem A.
author_facet Triano, Matthew
Fayed, Islam
Sandhu, Faheem A.
author_sort Triano, Matthew
collection PubMed
description BACKGROUND: Sacroiliac joint (SIJ) dysfunction can lead to significant pain and disability, greatly impairing quality of life. Arthrodesis may take up to 1 year to occur, after which revision can be considered. There is a need for highly accurate and reproducible techniques for revision that allow for purchase through undisturbed bone to prevent prolonged pain and disability. Moreover, a minimally invasive technique for revision would be favorable for recovery, particularly in elderly patients. OBSERVATIONS: An 84-year-old man with a prior history of lumbar fusion presented with severe buttock pain limiting ambulation and sitting because of the failure of arthrodesis after SIJ fusion 1 year earlier. He underwent revision using a triangular titanium implant (TTI) in an S2-alar-iliac (S2-AI) trajectory under robotic guidance, which is a novel technique not yet described in the literature. The patient’s pain largely resolved, he was able to ambulate independently, and his quality of life improved tremendously. There were no complications of surgery. LESSONS: Placement of a TTI using an S2-AI trajectory is a safe and effective method for revision that can be considered for elderly patients. Robot-assisted navigation can be used to facilitate an accurate and reproducible approach using a minimally invasive approach.
format Online
Article
Text
id pubmed-9272365
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher American Association of Neurological Surgeons
record_format MEDLINE/PubMed
spelling pubmed-92723652022-07-18 Robot-assisted revision of sacroiliac joint fusion using a triangular titanium implant in an S2-alar-iliac trajectory: illustrative case Triano, Matthew Fayed, Islam Sandhu, Faheem A. J Neurosurg Case Lessons Case Lesson BACKGROUND: Sacroiliac joint (SIJ) dysfunction can lead to significant pain and disability, greatly impairing quality of life. Arthrodesis may take up to 1 year to occur, after which revision can be considered. There is a need for highly accurate and reproducible techniques for revision that allow for purchase through undisturbed bone to prevent prolonged pain and disability. Moreover, a minimally invasive technique for revision would be favorable for recovery, particularly in elderly patients. OBSERVATIONS: An 84-year-old man with a prior history of lumbar fusion presented with severe buttock pain limiting ambulation and sitting because of the failure of arthrodesis after SIJ fusion 1 year earlier. He underwent revision using a triangular titanium implant (TTI) in an S2-alar-iliac (S2-AI) trajectory under robotic guidance, which is a novel technique not yet described in the literature. The patient’s pain largely resolved, he was able to ambulate independently, and his quality of life improved tremendously. There were no complications of surgery. LESSONS: Placement of a TTI using an S2-AI trajectory is a safe and effective method for revision that can be considered for elderly patients. Robot-assisted navigation can be used to facilitate an accurate and reproducible approach using a minimally invasive approach. American Association of Neurological Surgeons 2021-07-05 /pmc/articles/PMC9272365/ /pubmed/35854956 http://dx.doi.org/10.3171/CASE2169 Text en © 2021 The authors https://creativecommons.org/licenses/by-nc-nd/4.0/CC BY-NC-ND 4.0 (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) ).
spellingShingle Case Lesson
Triano, Matthew
Fayed, Islam
Sandhu, Faheem A.
Robot-assisted revision of sacroiliac joint fusion using a triangular titanium implant in an S2-alar-iliac trajectory: illustrative case
title Robot-assisted revision of sacroiliac joint fusion using a triangular titanium implant in an S2-alar-iliac trajectory: illustrative case
title_full Robot-assisted revision of sacroiliac joint fusion using a triangular titanium implant in an S2-alar-iliac trajectory: illustrative case
title_fullStr Robot-assisted revision of sacroiliac joint fusion using a triangular titanium implant in an S2-alar-iliac trajectory: illustrative case
title_full_unstemmed Robot-assisted revision of sacroiliac joint fusion using a triangular titanium implant in an S2-alar-iliac trajectory: illustrative case
title_short Robot-assisted revision of sacroiliac joint fusion using a triangular titanium implant in an S2-alar-iliac trajectory: illustrative case
title_sort robot-assisted revision of sacroiliac joint fusion using a triangular titanium implant in an s2-alar-iliac trajectory: illustrative case
topic Case Lesson
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9272365/
https://www.ncbi.nlm.nih.gov/pubmed/35854956
http://dx.doi.org/10.3171/CASE2169
work_keys_str_mv AT trianomatthew robotassistedrevisionofsacroiliacjointfusionusingatriangulartitaniumimplantinans2alariliactrajectoryillustrativecase
AT fayedislam robotassistedrevisionofsacroiliacjointfusionusingatriangulartitaniumimplantinans2alariliactrajectoryillustrativecase
AT sandhufaheema robotassistedrevisionofsacroiliacjointfusionusingatriangulartitaniumimplantinans2alariliactrajectoryillustrativecase