Cargando…

Radiobiological Comparison of Acuros External Beam and Anisotropic Analytical Algorithm on Esophageal Carcinoma Radiotherapy Treatment Plans

OBJECTIVE: The present study aimed to investigate the dose differences and radiobiological assessment between Anisotropic Analytical Algorithm (AAA) and Acuros External Beam (AXB) with its 2 calculation models, namely, dose-to-water (AXB-Dw) and dose-to-medium (AXB-Dm), on esophageal carcinoma radio...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Lin, Zhang, Jianping, Huang, Miaoyun, Xu, Benhua, Li, Xiaobo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9272482/
https://www.ncbi.nlm.nih.gov/pubmed/35832770
http://dx.doi.org/10.1177/15593258221105678
_version_ 1784744882268536832
author Wang, Lin
Zhang, Jianping
Huang, Miaoyun
Xu, Benhua
Li, Xiaobo
author_facet Wang, Lin
Zhang, Jianping
Huang, Miaoyun
Xu, Benhua
Li, Xiaobo
author_sort Wang, Lin
collection PubMed
description OBJECTIVE: The present study aimed to investigate the dose differences and radiobiological assessment between Anisotropic Analytical Algorithm (AAA) and Acuros External Beam (AXB) with its 2 calculation models, namely, dose-to-water (AXB-Dw) and dose-to-medium (AXB-Dm), on esophageal carcinoma radiotherapy treatment plans. MATERIALS AND METHODS: The AXB-Dw and AXB-Dm plans were generated by recalculating the initial 66 AAA plans using the AXB algorithm with the same monitor units and beam parameters as those in the original plan. The dosimetric and radiobiological assessment parameters were calculated for the planning target volume (PTV) and organs at risk (OARs). The gamma agreement for the PTV and the correlation between it and the volume of the air cavity and bone among the different algorithms were compared simultaneously. The dose discrepancy between the theoretical calculation and treatment planning system (TPS) when switching from AXB-Dm to AXB-Dw was analyzed according to the composition of the structures. RESULTS: The PTV dose of AXB-Dm plans was significantly smaller than that of the AAA and AXB-Dw plans (P < .05), except for D(2). The difference values for AAA vs AXB-Dm (∆D(x,(AAA-AXB,Dm))) and AXB-Dw vs AXB-Dm (∆D(x,(AXB,Dw-AXB,Dm))) were 1.94% [1.27%, 2.64%] and 1.95% [1.56%, 2.27%], respectively. For the spinal cord and heart, there were obvious differences between the AAA vs AXB-Dm (spinal cord: 1.15%, heart: 2.89%) and AXB-Dw vs AXB-Dm (spinal cord: 1.88%, heart: 3.25%) plans. For the lung, the differences between AAA vs AXB-Dm and AAA vs AXB-Dw were significantly larger than those of AXB-Dm vs AXB-Dw. Compared to the case of AAA and AXB-Dw, the decrease in biologically effective dose (BED(10), [Formula: see text] ) of AXB-Dm due to dose non-uniformity exceeded 6.5%, even for a small [Formula: see text] . The average values of equivalent uniform dose in the AAA, AXB-Dw, and AXB-Dm plans were 52.03±.39 Gy, 52.24 ± .81 Gy, and 51.13 ± .47 Gy, respectively. The tumor control probability (TCP) results for PTV in the AAA, AXB-Dw, and AXB-Dm plans were 62.29 ± 1.57%, 62.82 ± 1.69%, and 58.68±1.88%, respectively. With the 2%/2 mm and 3%/3 mm acceptance criteria, the mean values of [Formula: see text] , [Formula: see text] , and [Formula: see text] were 87.24, 63.3, and 64.81% vs 97.86, 91.77, and 89.25%, respectively. The dose discrepancy between the theoretical calculation and TPS when switching from AXB-Dm to AXB-Dw was approximately 1.63%. CONCLUSIONS: The AAA and AXB-Dw algorithms overestimated the radiobiological parameters when the tumor particularly consisted of nonuniform tissues. A relatively small dose difference could cause a significant reduction in the corresponding TCP. Dose distribution algorithms should be carefully chosen by physicists and oncologists to improve tumor control, as well as to optimize OARs protection.
format Online
Article
Text
id pubmed-9272482
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-92724822022-07-12 Radiobiological Comparison of Acuros External Beam and Anisotropic Analytical Algorithm on Esophageal Carcinoma Radiotherapy Treatment Plans Wang, Lin Zhang, Jianping Huang, Miaoyun Xu, Benhua Li, Xiaobo Dose Response Original Article OBJECTIVE: The present study aimed to investigate the dose differences and radiobiological assessment between Anisotropic Analytical Algorithm (AAA) and Acuros External Beam (AXB) with its 2 calculation models, namely, dose-to-water (AXB-Dw) and dose-to-medium (AXB-Dm), on esophageal carcinoma radiotherapy treatment plans. MATERIALS AND METHODS: The AXB-Dw and AXB-Dm plans were generated by recalculating the initial 66 AAA plans using the AXB algorithm with the same monitor units and beam parameters as those in the original plan. The dosimetric and radiobiological assessment parameters were calculated for the planning target volume (PTV) and organs at risk (OARs). The gamma agreement for the PTV and the correlation between it and the volume of the air cavity and bone among the different algorithms were compared simultaneously. The dose discrepancy between the theoretical calculation and treatment planning system (TPS) when switching from AXB-Dm to AXB-Dw was analyzed according to the composition of the structures. RESULTS: The PTV dose of AXB-Dm plans was significantly smaller than that of the AAA and AXB-Dw plans (P < .05), except for D(2). The difference values for AAA vs AXB-Dm (∆D(x,(AAA-AXB,Dm))) and AXB-Dw vs AXB-Dm (∆D(x,(AXB,Dw-AXB,Dm))) were 1.94% [1.27%, 2.64%] and 1.95% [1.56%, 2.27%], respectively. For the spinal cord and heart, there were obvious differences between the AAA vs AXB-Dm (spinal cord: 1.15%, heart: 2.89%) and AXB-Dw vs AXB-Dm (spinal cord: 1.88%, heart: 3.25%) plans. For the lung, the differences between AAA vs AXB-Dm and AAA vs AXB-Dw were significantly larger than those of AXB-Dm vs AXB-Dw. Compared to the case of AAA and AXB-Dw, the decrease in biologically effective dose (BED(10), [Formula: see text] ) of AXB-Dm due to dose non-uniformity exceeded 6.5%, even for a small [Formula: see text] . The average values of equivalent uniform dose in the AAA, AXB-Dw, and AXB-Dm plans were 52.03±.39 Gy, 52.24 ± .81 Gy, and 51.13 ± .47 Gy, respectively. The tumor control probability (TCP) results for PTV in the AAA, AXB-Dw, and AXB-Dm plans were 62.29 ± 1.57%, 62.82 ± 1.69%, and 58.68±1.88%, respectively. With the 2%/2 mm and 3%/3 mm acceptance criteria, the mean values of [Formula: see text] , [Formula: see text] , and [Formula: see text] were 87.24, 63.3, and 64.81% vs 97.86, 91.77, and 89.25%, respectively. The dose discrepancy between the theoretical calculation and TPS when switching from AXB-Dm to AXB-Dw was approximately 1.63%. CONCLUSIONS: The AAA and AXB-Dw algorithms overestimated the radiobiological parameters when the tumor particularly consisted of nonuniform tissues. A relatively small dose difference could cause a significant reduction in the corresponding TCP. Dose distribution algorithms should be carefully chosen by physicists and oncologists to improve tumor control, as well as to optimize OARs protection. SAGE Publications 2022-07-08 /pmc/articles/PMC9272482/ /pubmed/35832770 http://dx.doi.org/10.1177/15593258221105678 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Wang, Lin
Zhang, Jianping
Huang, Miaoyun
Xu, Benhua
Li, Xiaobo
Radiobiological Comparison of Acuros External Beam and Anisotropic Analytical Algorithm on Esophageal Carcinoma Radiotherapy Treatment Plans
title Radiobiological Comparison of Acuros External Beam and Anisotropic Analytical Algorithm on Esophageal Carcinoma Radiotherapy Treatment Plans
title_full Radiobiological Comparison of Acuros External Beam and Anisotropic Analytical Algorithm on Esophageal Carcinoma Radiotherapy Treatment Plans
title_fullStr Radiobiological Comparison of Acuros External Beam and Anisotropic Analytical Algorithm on Esophageal Carcinoma Radiotherapy Treatment Plans
title_full_unstemmed Radiobiological Comparison of Acuros External Beam and Anisotropic Analytical Algorithm on Esophageal Carcinoma Radiotherapy Treatment Plans
title_short Radiobiological Comparison of Acuros External Beam and Anisotropic Analytical Algorithm on Esophageal Carcinoma Radiotherapy Treatment Plans
title_sort radiobiological comparison of acuros external beam and anisotropic analytical algorithm on esophageal carcinoma radiotherapy treatment plans
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9272482/
https://www.ncbi.nlm.nih.gov/pubmed/35832770
http://dx.doi.org/10.1177/15593258221105678
work_keys_str_mv AT wanglin radiobiologicalcomparisonofacurosexternalbeamandanisotropicanalyticalalgorithmonesophagealcarcinomaradiotherapytreatmentplans
AT zhangjianping radiobiologicalcomparisonofacurosexternalbeamandanisotropicanalyticalalgorithmonesophagealcarcinomaradiotherapytreatmentplans
AT huangmiaoyun radiobiologicalcomparisonofacurosexternalbeamandanisotropicanalyticalalgorithmonesophagealcarcinomaradiotherapytreatmentplans
AT xubenhua radiobiologicalcomparisonofacurosexternalbeamandanisotropicanalyticalalgorithmonesophagealcarcinomaradiotherapytreatmentplans
AT lixiaobo radiobiologicalcomparisonofacurosexternalbeamandanisotropicanalyticalalgorithmonesophagealcarcinomaradiotherapytreatmentplans