Cargando…

Case Report: Challenging Treatment of an AorticParavalvular Leak: How We Avoided Interference With Mechanical Valve Function?

BACKGROUND: Aortic paravalvular leak (APVL) after surgical valve replacement (AVR) is an ominous complication with a high risk of morbidity and mortality. Approximately 1–5% of PVLs can lead to serious clinical consequences, including congestive heart failure and/or hemolytic anemia. CASE SUMMARY: A...

Descripción completa

Detalles Bibliográficos
Autores principales: Onorato, Eustaquio Maria, Vercellino, Matteo, Costante, Annamaria, Bartorelli, Antonio L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9272523/
https://www.ncbi.nlm.nih.gov/pubmed/35833184
http://dx.doi.org/10.3389/fcvm.2022.839159
_version_ 1784744887278632960
author Onorato, Eustaquio Maria
Vercellino, Matteo
Costante, Annamaria
Bartorelli, Antonio L.
author_facet Onorato, Eustaquio Maria
Vercellino, Matteo
Costante, Annamaria
Bartorelli, Antonio L.
author_sort Onorato, Eustaquio Maria
collection PubMed
description BACKGROUND: Aortic paravalvular leak (APVL) after surgical valve replacement (AVR) is an ominous complication with a high risk of morbidity and mortality. Approximately 1–5% of PVLs can lead to serious clinical consequences, including congestive heart failure and/or hemolytic anemia. CASE SUMMARY: A 69-year-old man with multiple comorbidities underwent surgical replacement of the aortic valve with a mechanical tilting disc prosthetic valve (Medtronic Starlight 27 mm). Several years later, recurrent episodes of congestive heart failure and hemolytic anemia developed due to a large crescent-shaped aortic PVL located at non coronary cusp (NCC) 9–12 o'clock, with moderate-to-severe regurgitation. The patient was deemed at prohibitive surgical risk due to significant multiple comorbidities and a transcatheter PVL closure (TPVLc) was planned. The huge PVL was partially closed by a first specifically designed paravalvular leak device (PLD). The procedure was complicated by transient interference of the second PLD with mechanical prosthetic valve function. This issue has however been solved with correct manipulation, orientation and downsizing of the second device implanted. At 3-month and 13-month follow-up, the patient showed a relevant clinical improvement and good quality of life. 2D TTE color Doppler confirmed the stable position of the two PLDs with trace residual leak. DISCUSSION: Surgical redo has been considered the treatment of choice for symptomatic patients with PVLs. Notwithstanding, TPVLc is a less invasive alternative, particularly in patients at high surgical risk in whom early diagnosis and prompt interventional treatment are crucial for improving expectancy and quality of life. Dedicated devices, appropriate procedural techniques, and the close interaction between imaging modalities, allowed to deal successfully with a challenging case of severe symptomatic aortic PVL.
format Online
Article
Text
id pubmed-9272523
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-92725232022-07-12 Case Report: Challenging Treatment of an AorticParavalvular Leak: How We Avoided Interference With Mechanical Valve Function? Onorato, Eustaquio Maria Vercellino, Matteo Costante, Annamaria Bartorelli, Antonio L. Front Cardiovasc Med Cardiovascular Medicine BACKGROUND: Aortic paravalvular leak (APVL) after surgical valve replacement (AVR) is an ominous complication with a high risk of morbidity and mortality. Approximately 1–5% of PVLs can lead to serious clinical consequences, including congestive heart failure and/or hemolytic anemia. CASE SUMMARY: A 69-year-old man with multiple comorbidities underwent surgical replacement of the aortic valve with a mechanical tilting disc prosthetic valve (Medtronic Starlight 27 mm). Several years later, recurrent episodes of congestive heart failure and hemolytic anemia developed due to a large crescent-shaped aortic PVL located at non coronary cusp (NCC) 9–12 o'clock, with moderate-to-severe regurgitation. The patient was deemed at prohibitive surgical risk due to significant multiple comorbidities and a transcatheter PVL closure (TPVLc) was planned. The huge PVL was partially closed by a first specifically designed paravalvular leak device (PLD). The procedure was complicated by transient interference of the second PLD with mechanical prosthetic valve function. This issue has however been solved with correct manipulation, orientation and downsizing of the second device implanted. At 3-month and 13-month follow-up, the patient showed a relevant clinical improvement and good quality of life. 2D TTE color Doppler confirmed the stable position of the two PLDs with trace residual leak. DISCUSSION: Surgical redo has been considered the treatment of choice for symptomatic patients with PVLs. Notwithstanding, TPVLc is a less invasive alternative, particularly in patients at high surgical risk in whom early diagnosis and prompt interventional treatment are crucial for improving expectancy and quality of life. Dedicated devices, appropriate procedural techniques, and the close interaction between imaging modalities, allowed to deal successfully with a challenging case of severe symptomatic aortic PVL. Frontiers Media S.A. 2022-06-27 /pmc/articles/PMC9272523/ /pubmed/35833184 http://dx.doi.org/10.3389/fcvm.2022.839159 Text en Copyright © 2022 Onorato, Vercellino, Costante and Bartorelli. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Onorato, Eustaquio Maria
Vercellino, Matteo
Costante, Annamaria
Bartorelli, Antonio L.
Case Report: Challenging Treatment of an AorticParavalvular Leak: How We Avoided Interference With Mechanical Valve Function?
title Case Report: Challenging Treatment of an AorticParavalvular Leak: How We Avoided Interference With Mechanical Valve Function?
title_full Case Report: Challenging Treatment of an AorticParavalvular Leak: How We Avoided Interference With Mechanical Valve Function?
title_fullStr Case Report: Challenging Treatment of an AorticParavalvular Leak: How We Avoided Interference With Mechanical Valve Function?
title_full_unstemmed Case Report: Challenging Treatment of an AorticParavalvular Leak: How We Avoided Interference With Mechanical Valve Function?
title_short Case Report: Challenging Treatment of an AorticParavalvular Leak: How We Avoided Interference With Mechanical Valve Function?
title_sort case report: challenging treatment of an aorticparavalvular leak: how we avoided interference with mechanical valve function?
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9272523/
https://www.ncbi.nlm.nih.gov/pubmed/35833184
http://dx.doi.org/10.3389/fcvm.2022.839159
work_keys_str_mv AT onoratoeustaquiomaria casereportchallengingtreatmentofanaorticparavalvularleakhowweavoidedinterferencewithmechanicalvalvefunction
AT vercellinomatteo casereportchallengingtreatmentofanaorticparavalvularleakhowweavoidedinterferencewithmechanicalvalvefunction
AT costanteannamaria casereportchallengingtreatmentofanaorticparavalvularleakhowweavoidedinterferencewithmechanicalvalvefunction
AT bartorelliantoniol casereportchallengingtreatmentofanaorticparavalvularleakhowweavoidedinterferencewithmechanicalvalvefunction