Cargando…

Xpert MTB/RIF Ultra versus Xpert MTB/RIF for diagnosis of tuberculous pleural effusion: A systematic review and comparative meta-analysis

OBJECTIVE: We compared diagnostic accuracy of pleural fluid Xpert MTB/RIF (Xpert) and Xpert MTB/RIF Ultra (Ultra) assays for diagnosing tuberculous pleural effusion (TPE), through systematic review and comparative meta-analysis. METHODS: We searched PubMed and Embase databases for publications repor...

Descripción completa

Detalles Bibliográficos
Autores principales: Aggarwal, Ashutosh Nath, Agarwal, Ritesh, Dhooria, Sahajal, Prasad, Kuruswamy Thurai, Sehgal, Inderpaul Singh, Muthu, Valliappan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9273090/
https://www.ncbi.nlm.nih.gov/pubmed/35816471
http://dx.doi.org/10.1371/journal.pone.0268483
_version_ 1784745000379088896
author Aggarwal, Ashutosh Nath
Agarwal, Ritesh
Dhooria, Sahajal
Prasad, Kuruswamy Thurai
Sehgal, Inderpaul Singh
Muthu, Valliappan
author_facet Aggarwal, Ashutosh Nath
Agarwal, Ritesh
Dhooria, Sahajal
Prasad, Kuruswamy Thurai
Sehgal, Inderpaul Singh
Muthu, Valliappan
author_sort Aggarwal, Ashutosh Nath
collection PubMed
description OBJECTIVE: We compared diagnostic accuracy of pleural fluid Xpert MTB/RIF (Xpert) and Xpert MTB/RIF Ultra (Ultra) assays for diagnosing tuberculous pleural effusion (TPE), through systematic review and comparative meta-analysis. METHODS: We searched PubMed and Embase databases for publications reporting diagnostic accuracy of Xpert or Ultra for TPE. We used bivariate random-effects modeling to summarize diagnostic accuracy information from individual studies using either mycobacterial culture or composite criteria as reference standard. We performed meta-regression through hierarchical summary receiver operating characteristic (HSROC) modeling to evaluate comparative performance of the two tests from studies reporting diagnostic accuracy of both in the same study population. RESULTS: We retrieved 1097 publications, and included 74 for review. Summary estimates for sensitivity and specificity for Xpert were 0.52 (95% CI 0.43–0.60, I(2) 82.1%) and 0.99 (95% CI 0.97–0.99, I(2) 85.1%), respectively, using culture-based reference standard; and 0.21 (95% CI 0.17–0.26, I(2) 81.5%) and 1.00 (95% CI 0.99–1.00, I(2) 37.6%), respectively, using composite reference standard. Summary estimates for sensitivity and specificity for Ultra were 0.68 (95% CI 0.55–0.79, I(2) 80.0%) and 0.97 (95% CI 0.97–0.99, I(2) 92.1%), respectively, using culture-based reference standard; and 0.47 (95% CI 0.40–0.55, I(2) 64.1%) and 0.98 (95% CI 0.95–0.99, I(2) 54.8%), respectively, using composite reference standard. HSROC meta-regression yielded relative diagnostic odds ratio of 1.28 (95% CI 0.65–2.50) and 1.80 (95% CI 0.41–7.84) respectively in favor of Ultra, using culture and composite criteria as reference standard. CONCLUSION: Ultra provides superior diagnostic accuracy over Xpert for diagnosing TPE, mainly because of its higher sensitivity.
format Online
Article
Text
id pubmed-9273090
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-92730902022-07-12 Xpert MTB/RIF Ultra versus Xpert MTB/RIF for diagnosis of tuberculous pleural effusion: A systematic review and comparative meta-analysis Aggarwal, Ashutosh Nath Agarwal, Ritesh Dhooria, Sahajal Prasad, Kuruswamy Thurai Sehgal, Inderpaul Singh Muthu, Valliappan PLoS One Research Article OBJECTIVE: We compared diagnostic accuracy of pleural fluid Xpert MTB/RIF (Xpert) and Xpert MTB/RIF Ultra (Ultra) assays for diagnosing tuberculous pleural effusion (TPE), through systematic review and comparative meta-analysis. METHODS: We searched PubMed and Embase databases for publications reporting diagnostic accuracy of Xpert or Ultra for TPE. We used bivariate random-effects modeling to summarize diagnostic accuracy information from individual studies using either mycobacterial culture or composite criteria as reference standard. We performed meta-regression through hierarchical summary receiver operating characteristic (HSROC) modeling to evaluate comparative performance of the two tests from studies reporting diagnostic accuracy of both in the same study population. RESULTS: We retrieved 1097 publications, and included 74 for review. Summary estimates for sensitivity and specificity for Xpert were 0.52 (95% CI 0.43–0.60, I(2) 82.1%) and 0.99 (95% CI 0.97–0.99, I(2) 85.1%), respectively, using culture-based reference standard; and 0.21 (95% CI 0.17–0.26, I(2) 81.5%) and 1.00 (95% CI 0.99–1.00, I(2) 37.6%), respectively, using composite reference standard. Summary estimates for sensitivity and specificity for Ultra were 0.68 (95% CI 0.55–0.79, I(2) 80.0%) and 0.97 (95% CI 0.97–0.99, I(2) 92.1%), respectively, using culture-based reference standard; and 0.47 (95% CI 0.40–0.55, I(2) 64.1%) and 0.98 (95% CI 0.95–0.99, I(2) 54.8%), respectively, using composite reference standard. HSROC meta-regression yielded relative diagnostic odds ratio of 1.28 (95% CI 0.65–2.50) and 1.80 (95% CI 0.41–7.84) respectively in favor of Ultra, using culture and composite criteria as reference standard. CONCLUSION: Ultra provides superior diagnostic accuracy over Xpert for diagnosing TPE, mainly because of its higher sensitivity. Public Library of Science 2022-07-11 /pmc/articles/PMC9273090/ /pubmed/35816471 http://dx.doi.org/10.1371/journal.pone.0268483 Text en © 2022 Aggarwal et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Aggarwal, Ashutosh Nath
Agarwal, Ritesh
Dhooria, Sahajal
Prasad, Kuruswamy Thurai
Sehgal, Inderpaul Singh
Muthu, Valliappan
Xpert MTB/RIF Ultra versus Xpert MTB/RIF for diagnosis of tuberculous pleural effusion: A systematic review and comparative meta-analysis
title Xpert MTB/RIF Ultra versus Xpert MTB/RIF for diagnosis of tuberculous pleural effusion: A systematic review and comparative meta-analysis
title_full Xpert MTB/RIF Ultra versus Xpert MTB/RIF for diagnosis of tuberculous pleural effusion: A systematic review and comparative meta-analysis
title_fullStr Xpert MTB/RIF Ultra versus Xpert MTB/RIF for diagnosis of tuberculous pleural effusion: A systematic review and comparative meta-analysis
title_full_unstemmed Xpert MTB/RIF Ultra versus Xpert MTB/RIF for diagnosis of tuberculous pleural effusion: A systematic review and comparative meta-analysis
title_short Xpert MTB/RIF Ultra versus Xpert MTB/RIF for diagnosis of tuberculous pleural effusion: A systematic review and comparative meta-analysis
title_sort xpert mtb/rif ultra versus xpert mtb/rif for diagnosis of tuberculous pleural effusion: a systematic review and comparative meta-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9273090/
https://www.ncbi.nlm.nih.gov/pubmed/35816471
http://dx.doi.org/10.1371/journal.pone.0268483
work_keys_str_mv AT aggarwalashutoshnath xpertmtbrifultraversusxpertmtbriffordiagnosisoftuberculouspleuraleffusionasystematicreviewandcomparativemetaanalysis
AT agarwalritesh xpertmtbrifultraversusxpertmtbriffordiagnosisoftuberculouspleuraleffusionasystematicreviewandcomparativemetaanalysis
AT dhooriasahajal xpertmtbrifultraversusxpertmtbriffordiagnosisoftuberculouspleuraleffusionasystematicreviewandcomparativemetaanalysis
AT prasadkuruswamythurai xpertmtbrifultraversusxpertmtbriffordiagnosisoftuberculouspleuraleffusionasystematicreviewandcomparativemetaanalysis
AT sehgalinderpaulsingh xpertmtbrifultraversusxpertmtbriffordiagnosisoftuberculouspleuraleffusionasystematicreviewandcomparativemetaanalysis
AT muthuvalliappan xpertmtbrifultraversusxpertmtbriffordiagnosisoftuberculouspleuraleffusionasystematicreviewandcomparativemetaanalysis