Cargando…
A Modified Deep Learning Framework for Arrhythmia Disease Analysis in Medical Imaging Using Electrocardiogram Signal
Arrhythmias are anomalies in the heartbeat rhythm that occur occasionally in people's lives. These arrhythmias can lead to potentially deadly consequences, putting your life in jeopardy. As a result, arrhythmia identification and classification are an important aspect of cardiac diagnostics. An...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9273451/ https://www.ncbi.nlm.nih.gov/pubmed/35832849 http://dx.doi.org/10.1155/2022/5203401 |
_version_ | 1784745077698985984 |
---|---|
author | Anbarasi, A. Ravi, T. Manjula, V. S. Brindha, J. Saranya, S. Ramkumar, G. Rathi, R. |
author_facet | Anbarasi, A. Ravi, T. Manjula, V. S. Brindha, J. Saranya, S. Ramkumar, G. Rathi, R. |
author_sort | Anbarasi, A. |
collection | PubMed |
description | Arrhythmias are anomalies in the heartbeat rhythm that occur occasionally in people's lives. These arrhythmias can lead to potentially deadly consequences, putting your life in jeopardy. As a result, arrhythmia identification and classification are an important aspect of cardiac diagnostics. An electrocardiogram (ECG), a recording collecting the heart's pumping activity, is regarded the guideline for catching these abnormal episodes. Nevertheless, because the ECG contains so much data, extracting the crucial data from imagery evaluation becomes extremely difficult. As a result, it is vital to create an effective system for analyzing ECG's massive amount of data. The ECG image from ECG signal is processed by some image processing techniques. To optimize the identification and categorization process, this research presents a hybrid deep learning-based technique. This paper contributes in two ways. Automating noise reduction and extraction of features, 1D ECG data are first converted into 2D pictures. Then, based on experimental evidence, a hybrid model called CNNLSTM is presented, which combines CNN and LSTM models. We conducted a comprehensive research using the broadly used MIT_BIH arrhythmia dataset to assess the efficacy of the proposed CNN-LSTM technique. The results reveal that the proposed method has a 99.10 percent accuracy rate. Furthermore, the proposed model has an average sensitivity of 98.35 percent and a specificity of 98.38 percent. These outcomes are superior to those produced using other procedures, and they will significantly reduce the amount of involvement necessary by physicians. |
format | Online Article Text |
id | pubmed-9273451 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-92734512022-07-12 A Modified Deep Learning Framework for Arrhythmia Disease Analysis in Medical Imaging Using Electrocardiogram Signal Anbarasi, A. Ravi, T. Manjula, V. S. Brindha, J. Saranya, S. Ramkumar, G. Rathi, R. Biomed Res Int Research Article Arrhythmias are anomalies in the heartbeat rhythm that occur occasionally in people's lives. These arrhythmias can lead to potentially deadly consequences, putting your life in jeopardy. As a result, arrhythmia identification and classification are an important aspect of cardiac diagnostics. An electrocardiogram (ECG), a recording collecting the heart's pumping activity, is regarded the guideline for catching these abnormal episodes. Nevertheless, because the ECG contains so much data, extracting the crucial data from imagery evaluation becomes extremely difficult. As a result, it is vital to create an effective system for analyzing ECG's massive amount of data. The ECG image from ECG signal is processed by some image processing techniques. To optimize the identification and categorization process, this research presents a hybrid deep learning-based technique. This paper contributes in two ways. Automating noise reduction and extraction of features, 1D ECG data are first converted into 2D pictures. Then, based on experimental evidence, a hybrid model called CNNLSTM is presented, which combines CNN and LSTM models. We conducted a comprehensive research using the broadly used MIT_BIH arrhythmia dataset to assess the efficacy of the proposed CNN-LSTM technique. The results reveal that the proposed method has a 99.10 percent accuracy rate. Furthermore, the proposed model has an average sensitivity of 98.35 percent and a specificity of 98.38 percent. These outcomes are superior to those produced using other procedures, and they will significantly reduce the amount of involvement necessary by physicians. Hindawi 2022-07-04 /pmc/articles/PMC9273451/ /pubmed/35832849 http://dx.doi.org/10.1155/2022/5203401 Text en Copyright © 2022 A. Anbarasi et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Anbarasi, A. Ravi, T. Manjula, V. S. Brindha, J. Saranya, S. Ramkumar, G. Rathi, R. A Modified Deep Learning Framework for Arrhythmia Disease Analysis in Medical Imaging Using Electrocardiogram Signal |
title | A Modified Deep Learning Framework for Arrhythmia Disease Analysis in Medical Imaging Using Electrocardiogram Signal |
title_full | A Modified Deep Learning Framework for Arrhythmia Disease Analysis in Medical Imaging Using Electrocardiogram Signal |
title_fullStr | A Modified Deep Learning Framework for Arrhythmia Disease Analysis in Medical Imaging Using Electrocardiogram Signal |
title_full_unstemmed | A Modified Deep Learning Framework for Arrhythmia Disease Analysis in Medical Imaging Using Electrocardiogram Signal |
title_short | A Modified Deep Learning Framework for Arrhythmia Disease Analysis in Medical Imaging Using Electrocardiogram Signal |
title_sort | modified deep learning framework for arrhythmia disease analysis in medical imaging using electrocardiogram signal |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9273451/ https://www.ncbi.nlm.nih.gov/pubmed/35832849 http://dx.doi.org/10.1155/2022/5203401 |
work_keys_str_mv | AT anbarasia amodifieddeeplearningframeworkforarrhythmiadiseaseanalysisinmedicalimagingusingelectrocardiogramsignal AT ravit amodifieddeeplearningframeworkforarrhythmiadiseaseanalysisinmedicalimagingusingelectrocardiogramsignal AT manjulavs amodifieddeeplearningframeworkforarrhythmiadiseaseanalysisinmedicalimagingusingelectrocardiogramsignal AT brindhaj amodifieddeeplearningframeworkforarrhythmiadiseaseanalysisinmedicalimagingusingelectrocardiogramsignal AT saranyas amodifieddeeplearningframeworkforarrhythmiadiseaseanalysisinmedicalimagingusingelectrocardiogramsignal AT ramkumarg amodifieddeeplearningframeworkforarrhythmiadiseaseanalysisinmedicalimagingusingelectrocardiogramsignal AT rathir amodifieddeeplearningframeworkforarrhythmiadiseaseanalysisinmedicalimagingusingelectrocardiogramsignal AT anbarasia modifieddeeplearningframeworkforarrhythmiadiseaseanalysisinmedicalimagingusingelectrocardiogramsignal AT ravit modifieddeeplearningframeworkforarrhythmiadiseaseanalysisinmedicalimagingusingelectrocardiogramsignal AT manjulavs modifieddeeplearningframeworkforarrhythmiadiseaseanalysisinmedicalimagingusingelectrocardiogramsignal AT brindhaj modifieddeeplearningframeworkforarrhythmiadiseaseanalysisinmedicalimagingusingelectrocardiogramsignal AT saranyas modifieddeeplearningframeworkforarrhythmiadiseaseanalysisinmedicalimagingusingelectrocardiogramsignal AT ramkumarg modifieddeeplearningframeworkforarrhythmiadiseaseanalysisinmedicalimagingusingelectrocardiogramsignal AT rathir modifieddeeplearningframeworkforarrhythmiadiseaseanalysisinmedicalimagingusingelectrocardiogramsignal |