Cargando…

One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening

Background: The diagnosis of osteoporosis is still one of the most critical topics for orthopedic surgeons worldwide. One research direction is to use existing clinical imaging data for accurate measurements of bone mineral density (BMD) without additional radiation. Methods: A novel phantom-less qu...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiongfeng, Tang, Cheng, Zhang, Meng, He, Chi, Ma, Deming, Guo, Huan, Qi, Bo, Chen, Kedi, Yang, Xianyue, Shen, Tak-Man, Wong, William Weijia, Lu, Yanguo, Qin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9273929/
https://www.ncbi.nlm.nih.gov/pubmed/35837549
http://dx.doi.org/10.3389/fbioe.2022.856753
_version_ 1784745201509597184
author Xiongfeng, Tang
Cheng, Zhang
Meng, He
Chi, Ma
Deming, Guo
Huan, Qi
Bo, Chen
Kedi, Yang
Xianyue, Shen
Tak-Man, Wong
William Weijia, Lu
Yanguo, Qin
author_facet Xiongfeng, Tang
Cheng, Zhang
Meng, He
Chi, Ma
Deming, Guo
Huan, Qi
Bo, Chen
Kedi, Yang
Xianyue, Shen
Tak-Man, Wong
William Weijia, Lu
Yanguo, Qin
author_sort Xiongfeng, Tang
collection PubMed
description Background: The diagnosis of osteoporosis is still one of the most critical topics for orthopedic surgeons worldwide. One research direction is to use existing clinical imaging data for accurate measurements of bone mineral density (BMD) without additional radiation. Methods: A novel phantom-less quantitative computed tomography (PL-QCT) system was developed to measure BMD and diagnose osteoporosis, as our previous study reported. Compared with traditional phantom-less QCT, this tool can conduct an automatic selection of body tissues and complete the BMD calibration with high efficacy and precision. The function has great advantages in big data screening and thus expands the scope of use of this novel PL-QCT. In this study, we utilized lung cancer or COVID-19 screening low-dose computed tomography (LDCT) of 649 patients for BMD calibration by the novel PL-QCT, and we made the BMD changes with age based on this PL-QCT. Results: The results show that the novel PL-QCT can predict osteoporosis with relatively high accuracy and precision using LDCT, and the AUC values range from 0.68 to 0.88 with DXA results as diagnosis reference. The relationship between PL-QCT BMD with age is close to the real trend population (from ∼160 mg/cc in less than 30 years old to ∼70 mg/cc in greater than 80 years old for both female and male groups). Additionally, the calculation results of Pearson’s r-values for correlation between CT values with BMD in different CT devices were 0.85–0.99. Conclusion: To our knowledge, it is the first time for automatic PL-QCT to evaluate the performance against dual-energy X-ray absorptiometry (DXA) in LDCT images. The results indicate that it may be a promising tool for individuals screened for low-dose chest computed tomography.
format Online
Article
Text
id pubmed-9273929
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-92739292022-07-13 One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening Xiongfeng, Tang Cheng, Zhang Meng, He Chi, Ma Deming, Guo Huan, Qi Bo, Chen Kedi, Yang Xianyue, Shen Tak-Man, Wong William Weijia, Lu Yanguo, Qin Front Bioeng Biotechnol Bioengineering and Biotechnology Background: The diagnosis of osteoporosis is still one of the most critical topics for orthopedic surgeons worldwide. One research direction is to use existing clinical imaging data for accurate measurements of bone mineral density (BMD) without additional radiation. Methods: A novel phantom-less quantitative computed tomography (PL-QCT) system was developed to measure BMD and diagnose osteoporosis, as our previous study reported. Compared with traditional phantom-less QCT, this tool can conduct an automatic selection of body tissues and complete the BMD calibration with high efficacy and precision. The function has great advantages in big data screening and thus expands the scope of use of this novel PL-QCT. In this study, we utilized lung cancer or COVID-19 screening low-dose computed tomography (LDCT) of 649 patients for BMD calibration by the novel PL-QCT, and we made the BMD changes with age based on this PL-QCT. Results: The results show that the novel PL-QCT can predict osteoporosis with relatively high accuracy and precision using LDCT, and the AUC values range from 0.68 to 0.88 with DXA results as diagnosis reference. The relationship between PL-QCT BMD with age is close to the real trend population (from ∼160 mg/cc in less than 30 years old to ∼70 mg/cc in greater than 80 years old for both female and male groups). Additionally, the calculation results of Pearson’s r-values for correlation between CT values with BMD in different CT devices were 0.85–0.99. Conclusion: To our knowledge, it is the first time for automatic PL-QCT to evaluate the performance against dual-energy X-ray absorptiometry (DXA) in LDCT images. The results indicate that it may be a promising tool for individuals screened for low-dose chest computed tomography. Frontiers Media S.A. 2022-06-28 /pmc/articles/PMC9273929/ /pubmed/35837549 http://dx.doi.org/10.3389/fbioe.2022.856753 Text en Copyright © 2022 Xiongfeng, Cheng, Meng, Chi, Deming, Huan, Bo, Kedi, Xianyue, Tak-Man, William Weijia and Yanguo. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Xiongfeng, Tang
Cheng, Zhang
Meng, He
Chi, Ma
Deming, Guo
Huan, Qi
Bo, Chen
Kedi, Yang
Xianyue, Shen
Tak-Man, Wong
William Weijia, Lu
Yanguo, Qin
One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening
title One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening
title_full One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening
title_fullStr One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening
title_full_unstemmed One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening
title_short One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening
title_sort one novel phantom-less quantitative computed tomography system for auto-diagnosis of osteoporosis utilizes low-dose chest computed tomography obtained for covid-19 screening
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9273929/
https://www.ncbi.nlm.nih.gov/pubmed/35837549
http://dx.doi.org/10.3389/fbioe.2022.856753
work_keys_str_mv AT xiongfengtang onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening
AT chengzhang onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening
AT menghe onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening
AT chima onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening
AT demingguo onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening
AT huanqi onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening
AT bochen onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening
AT kediyang onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening
AT xianyueshen onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening
AT takmanwong onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening
AT williamweijialu onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening
AT yanguoqin onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening