Cargando…
One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening
Background: The diagnosis of osteoporosis is still one of the most critical topics for orthopedic surgeons worldwide. One research direction is to use existing clinical imaging data for accurate measurements of bone mineral density (BMD) without additional radiation. Methods: A novel phantom-less qu...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9273929/ https://www.ncbi.nlm.nih.gov/pubmed/35837549 http://dx.doi.org/10.3389/fbioe.2022.856753 |
_version_ | 1784745201509597184 |
---|---|
author | Xiongfeng, Tang Cheng, Zhang Meng, He Chi, Ma Deming, Guo Huan, Qi Bo, Chen Kedi, Yang Xianyue, Shen Tak-Man, Wong William Weijia, Lu Yanguo, Qin |
author_facet | Xiongfeng, Tang Cheng, Zhang Meng, He Chi, Ma Deming, Guo Huan, Qi Bo, Chen Kedi, Yang Xianyue, Shen Tak-Man, Wong William Weijia, Lu Yanguo, Qin |
author_sort | Xiongfeng, Tang |
collection | PubMed |
description | Background: The diagnosis of osteoporosis is still one of the most critical topics for orthopedic surgeons worldwide. One research direction is to use existing clinical imaging data for accurate measurements of bone mineral density (BMD) without additional radiation. Methods: A novel phantom-less quantitative computed tomography (PL-QCT) system was developed to measure BMD and diagnose osteoporosis, as our previous study reported. Compared with traditional phantom-less QCT, this tool can conduct an automatic selection of body tissues and complete the BMD calibration with high efficacy and precision. The function has great advantages in big data screening and thus expands the scope of use of this novel PL-QCT. In this study, we utilized lung cancer or COVID-19 screening low-dose computed tomography (LDCT) of 649 patients for BMD calibration by the novel PL-QCT, and we made the BMD changes with age based on this PL-QCT. Results: The results show that the novel PL-QCT can predict osteoporosis with relatively high accuracy and precision using LDCT, and the AUC values range from 0.68 to 0.88 with DXA results as diagnosis reference. The relationship between PL-QCT BMD with age is close to the real trend population (from ∼160 mg/cc in less than 30 years old to ∼70 mg/cc in greater than 80 years old for both female and male groups). Additionally, the calculation results of Pearson’s r-values for correlation between CT values with BMD in different CT devices were 0.85–0.99. Conclusion: To our knowledge, it is the first time for automatic PL-QCT to evaluate the performance against dual-energy X-ray absorptiometry (DXA) in LDCT images. The results indicate that it may be a promising tool for individuals screened for low-dose chest computed tomography. |
format | Online Article Text |
id | pubmed-9273929 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-92739292022-07-13 One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening Xiongfeng, Tang Cheng, Zhang Meng, He Chi, Ma Deming, Guo Huan, Qi Bo, Chen Kedi, Yang Xianyue, Shen Tak-Man, Wong William Weijia, Lu Yanguo, Qin Front Bioeng Biotechnol Bioengineering and Biotechnology Background: The diagnosis of osteoporosis is still one of the most critical topics for orthopedic surgeons worldwide. One research direction is to use existing clinical imaging data for accurate measurements of bone mineral density (BMD) without additional radiation. Methods: A novel phantom-less quantitative computed tomography (PL-QCT) system was developed to measure BMD and diagnose osteoporosis, as our previous study reported. Compared with traditional phantom-less QCT, this tool can conduct an automatic selection of body tissues and complete the BMD calibration with high efficacy and precision. The function has great advantages in big data screening and thus expands the scope of use of this novel PL-QCT. In this study, we utilized lung cancer or COVID-19 screening low-dose computed tomography (LDCT) of 649 patients for BMD calibration by the novel PL-QCT, and we made the BMD changes with age based on this PL-QCT. Results: The results show that the novel PL-QCT can predict osteoporosis with relatively high accuracy and precision using LDCT, and the AUC values range from 0.68 to 0.88 with DXA results as diagnosis reference. The relationship between PL-QCT BMD with age is close to the real trend population (from ∼160 mg/cc in less than 30 years old to ∼70 mg/cc in greater than 80 years old for both female and male groups). Additionally, the calculation results of Pearson’s r-values for correlation between CT values with BMD in different CT devices were 0.85–0.99. Conclusion: To our knowledge, it is the first time for automatic PL-QCT to evaluate the performance against dual-energy X-ray absorptiometry (DXA) in LDCT images. The results indicate that it may be a promising tool for individuals screened for low-dose chest computed tomography. Frontiers Media S.A. 2022-06-28 /pmc/articles/PMC9273929/ /pubmed/35837549 http://dx.doi.org/10.3389/fbioe.2022.856753 Text en Copyright © 2022 Xiongfeng, Cheng, Meng, Chi, Deming, Huan, Bo, Kedi, Xianyue, Tak-Man, William Weijia and Yanguo. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Xiongfeng, Tang Cheng, Zhang Meng, He Chi, Ma Deming, Guo Huan, Qi Bo, Chen Kedi, Yang Xianyue, Shen Tak-Man, Wong William Weijia, Lu Yanguo, Qin One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening |
title | One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening |
title_full | One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening |
title_fullStr | One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening |
title_full_unstemmed | One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening |
title_short | One Novel Phantom-Less Quantitative Computed Tomography System for Auto-Diagnosis of Osteoporosis Utilizes Low-Dose Chest Computed Tomography Obtained for COVID-19 Screening |
title_sort | one novel phantom-less quantitative computed tomography system for auto-diagnosis of osteoporosis utilizes low-dose chest computed tomography obtained for covid-19 screening |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9273929/ https://www.ncbi.nlm.nih.gov/pubmed/35837549 http://dx.doi.org/10.3389/fbioe.2022.856753 |
work_keys_str_mv | AT xiongfengtang onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening AT chengzhang onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening AT menghe onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening AT chima onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening AT demingguo onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening AT huanqi onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening AT bochen onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening AT kediyang onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening AT xianyueshen onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening AT takmanwong onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening AT williamweijialu onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening AT yanguoqin onenovelphantomlessquantitativecomputedtomographysystemforautodiagnosisofosteoporosisutilizeslowdosechestcomputedtomographyobtainedforcovid19screening |