Cargando…
Advantages, Pitfalls, and Developments of All Optical Interrogation Strategies of Microcircuits in vivo
The holy grail for every neurophysiologist is to conclude a causal relationship between an elementary behaviour and the function of a specific brain area or circuit. Our effort to map elementary behaviours to specific brain loci and to further manipulate neural activity while observing the alteratio...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9274136/ https://www.ncbi.nlm.nih.gov/pubmed/35837124 http://dx.doi.org/10.3389/fnins.2022.859803 |
_version_ | 1784745240263917568 |
---|---|
author | Papaioannou, Stylianos Medini, Paolo |
author_facet | Papaioannou, Stylianos Medini, Paolo |
author_sort | Papaioannou, Stylianos |
collection | PubMed |
description | The holy grail for every neurophysiologist is to conclude a causal relationship between an elementary behaviour and the function of a specific brain area or circuit. Our effort to map elementary behaviours to specific brain loci and to further manipulate neural activity while observing the alterations in behaviour is in essence the goal for neuroscientists. Recent advancements in the area of experimental brain imaging in the form of longer wavelength near infrared (NIR) pulsed lasers with the development of highly efficient optogenetic actuators and reporters of neural activity, has endowed us with unprecedented resolution in spatiotemporal precision both in imaging neural activity as well as manipulating it with multiphoton microscopy. This readily available toolbox has introduced a so called all-optical physiology and interrogation of circuits and has opened new horizons when it comes to precisely, fast and non-invasively map and manipulate anatomically, molecularly or functionally identified mesoscopic brain circuits. The purpose of this review is to describe the advantages and possible pitfalls of all-optical approaches in system neuroscience, where by all-optical we mean use of multiphoton microscopy to image the functional response of neuron(s) in the network so to attain flexible choice of the cells to be also optogenetically photostimulated by holography, in absence of electrophysiology. Spatio-temporal constraints will be compared toward the classical reference of electrophysiology methods. When appropriate, in relation to current limitations of current optical approaches, we will make reference to latest works aimed to overcome these limitations, in order to highlight the most recent developments. We will also provide examples of types of experiments uniquely approachable all-optically. Finally, although mechanically non-invasive, all-optical electrophysiology exhibits potential off-target effects which can ambiguate and complicate the interpretation of the results. In summary, this review is an effort to exemplify how an all-optical experiment can be designed, conducted and interpreted from the point of view of the integrative neurophysiologist. |
format | Online Article Text |
id | pubmed-9274136 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-92741362022-07-13 Advantages, Pitfalls, and Developments of All Optical Interrogation Strategies of Microcircuits in vivo Papaioannou, Stylianos Medini, Paolo Front Neurosci Neuroscience The holy grail for every neurophysiologist is to conclude a causal relationship between an elementary behaviour and the function of a specific brain area or circuit. Our effort to map elementary behaviours to specific brain loci and to further manipulate neural activity while observing the alterations in behaviour is in essence the goal for neuroscientists. Recent advancements in the area of experimental brain imaging in the form of longer wavelength near infrared (NIR) pulsed lasers with the development of highly efficient optogenetic actuators and reporters of neural activity, has endowed us with unprecedented resolution in spatiotemporal precision both in imaging neural activity as well as manipulating it with multiphoton microscopy. This readily available toolbox has introduced a so called all-optical physiology and interrogation of circuits and has opened new horizons when it comes to precisely, fast and non-invasively map and manipulate anatomically, molecularly or functionally identified mesoscopic brain circuits. The purpose of this review is to describe the advantages and possible pitfalls of all-optical approaches in system neuroscience, where by all-optical we mean use of multiphoton microscopy to image the functional response of neuron(s) in the network so to attain flexible choice of the cells to be also optogenetically photostimulated by holography, in absence of electrophysiology. Spatio-temporal constraints will be compared toward the classical reference of electrophysiology methods. When appropriate, in relation to current limitations of current optical approaches, we will make reference to latest works aimed to overcome these limitations, in order to highlight the most recent developments. We will also provide examples of types of experiments uniquely approachable all-optically. Finally, although mechanically non-invasive, all-optical electrophysiology exhibits potential off-target effects which can ambiguate and complicate the interpretation of the results. In summary, this review is an effort to exemplify how an all-optical experiment can be designed, conducted and interpreted from the point of view of the integrative neurophysiologist. Frontiers Media S.A. 2022-06-28 /pmc/articles/PMC9274136/ /pubmed/35837124 http://dx.doi.org/10.3389/fnins.2022.859803 Text en Copyright © 2022 Papaioannou and Medini. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neuroscience Papaioannou, Stylianos Medini, Paolo Advantages, Pitfalls, and Developments of All Optical Interrogation Strategies of Microcircuits in vivo |
title | Advantages, Pitfalls, and Developments of All Optical Interrogation Strategies of Microcircuits in vivo |
title_full | Advantages, Pitfalls, and Developments of All Optical Interrogation Strategies of Microcircuits in vivo |
title_fullStr | Advantages, Pitfalls, and Developments of All Optical Interrogation Strategies of Microcircuits in vivo |
title_full_unstemmed | Advantages, Pitfalls, and Developments of All Optical Interrogation Strategies of Microcircuits in vivo |
title_short | Advantages, Pitfalls, and Developments of All Optical Interrogation Strategies of Microcircuits in vivo |
title_sort | advantages, pitfalls, and developments of all optical interrogation strategies of microcircuits in vivo |
topic | Neuroscience |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9274136/ https://www.ncbi.nlm.nih.gov/pubmed/35837124 http://dx.doi.org/10.3389/fnins.2022.859803 |
work_keys_str_mv | AT papaioannoustylianos advantagespitfallsanddevelopmentsofallopticalinterrogationstrategiesofmicrocircuitsinvivo AT medinipaolo advantagespitfallsanddevelopmentsofallopticalinterrogationstrategiesofmicrocircuitsinvivo |