Cargando…
A Novel Method for Quantitative Three-Dimensional Analysis of Zygomatico-Maxillary Complex Symmetry
To develop a reliable and accurate method to quantify the symmetry of the zygomaticomaxillary complex (ZMC). METHODS: Virtual three-dimensional models were created from 53 computed-tomography scans: 15 healthy cases without maxillofacial disorders and 38 patients with ZMC fractures requiring surgica...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9275855/ https://www.ncbi.nlm.nih.gov/pubmed/34864750 http://dx.doi.org/10.1097/SCS.0000000000008382 |
_version_ | 1784745578673995776 |
---|---|
author | de Kort, W.W.B. van Hout, W.M.M.T. ten Harkel, T.C. van Cann, E.M. Rosenberg, A.J.W.P. |
author_facet | de Kort, W.W.B. van Hout, W.M.M.T. ten Harkel, T.C. van Cann, E.M. Rosenberg, A.J.W.P. |
author_sort | de Kort, W.W.B. |
collection | PubMed |
description | To develop a reliable and accurate method to quantify the symmetry of the zygomaticomaxillary complex (ZMC). METHODS: Virtual three-dimensional models were created from 53 computed-tomography scans: 15 healthy cases without maxillofacial disorders and 38 patients with ZMC fractures requiring surgical treatment. Asymmetry of the ZMC was measured using a mirroring and surface-based matching technique that uses the anterior cranial fossa as reference to determine the symmetrical position of the ZMC. The measure for ZMC asymmetry was defined as mean surface distance (MSD) between the ZMC-surface and the symmetrical position. Reliability of the method was tested in the 15 healthy cases. Inter-and intra-observer correlation coefficients (Ce) and variabilities were assessed. Accuracy was assessed by comparing ZMC asymmetry between healthy and ZMC fracture cases, and by assessing correlation of ZMC fracture severity with ZMC asymmetry. RESULTS: The average MSD of the 15 healthy cases was 1.40 ± 0.54 mm and the average MSD of the 38 ZMC fracture cases was 2.69 ± 0.95 mm (P < 0.01). Zygomaticomaxillary complex asymmetry correlated with fracture severity (P = 0.01). Intra-rater CC was 0.97 with an intra-rater variability of 0.09 ± 0.11 mm. Inter-rater Ce was 0.95 with an inter-rater variability of 0.12 ± 0.13 mm. CONCLUSIONS: Our method is reliable and accurate for quantitative three-dimensional analysis of ZMC-symmetry. It takes into account asymmetry caused by the shape of the ZMC as well as asymmetry caused by the position of the ZMC. CLINICAL RELEVANCE: This method is useful for the evaluation of ZMC asymmetry associated with congenital and acquired disorders of craniofacial skeleton, for surgical planning and for evaluation of postoperative results. |
format | Online Article Text |
id | pubmed-9275855 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-92758552022-08-02 A Novel Method for Quantitative Three-Dimensional Analysis of Zygomatico-Maxillary Complex Symmetry de Kort, W.W.B. van Hout, W.M.M.T. ten Harkel, T.C. van Cann, E.M. Rosenberg, A.J.W.P. J Craniofac Surg Clinical Studies To develop a reliable and accurate method to quantify the symmetry of the zygomaticomaxillary complex (ZMC). METHODS: Virtual three-dimensional models were created from 53 computed-tomography scans: 15 healthy cases without maxillofacial disorders and 38 patients with ZMC fractures requiring surgical treatment. Asymmetry of the ZMC was measured using a mirroring and surface-based matching technique that uses the anterior cranial fossa as reference to determine the symmetrical position of the ZMC. The measure for ZMC asymmetry was defined as mean surface distance (MSD) between the ZMC-surface and the symmetrical position. Reliability of the method was tested in the 15 healthy cases. Inter-and intra-observer correlation coefficients (Ce) and variabilities were assessed. Accuracy was assessed by comparing ZMC asymmetry between healthy and ZMC fracture cases, and by assessing correlation of ZMC fracture severity with ZMC asymmetry. RESULTS: The average MSD of the 15 healthy cases was 1.40 ± 0.54 mm and the average MSD of the 38 ZMC fracture cases was 2.69 ± 0.95 mm (P < 0.01). Zygomaticomaxillary complex asymmetry correlated with fracture severity (P = 0.01). Intra-rater CC was 0.97 with an intra-rater variability of 0.09 ± 0.11 mm. Inter-rater Ce was 0.95 with an inter-rater variability of 0.12 ± 0.13 mm. CONCLUSIONS: Our method is reliable and accurate for quantitative three-dimensional analysis of ZMC-symmetry. It takes into account asymmetry caused by the shape of the ZMC as well as asymmetry caused by the position of the ZMC. CLINICAL RELEVANCE: This method is useful for the evaluation of ZMC asymmetry associated with congenital and acquired disorders of craniofacial skeleton, for surgical planning and for evaluation of postoperative results. Lippincott Williams & Wilkins 2022 2021-12-03 /pmc/articles/PMC9275855/ /pubmed/34864750 http://dx.doi.org/10.1097/SCS.0000000000008382 Text en Copyright © 2021 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of Mutaz B. Habal, MD https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Clinical Studies de Kort, W.W.B. van Hout, W.M.M.T. ten Harkel, T.C. van Cann, E.M. Rosenberg, A.J.W.P. A Novel Method for Quantitative Three-Dimensional Analysis of Zygomatico-Maxillary Complex Symmetry |
title | A Novel Method for Quantitative Three-Dimensional Analysis of Zygomatico-Maxillary Complex Symmetry |
title_full | A Novel Method for Quantitative Three-Dimensional Analysis of Zygomatico-Maxillary Complex Symmetry |
title_fullStr | A Novel Method for Quantitative Three-Dimensional Analysis of Zygomatico-Maxillary Complex Symmetry |
title_full_unstemmed | A Novel Method for Quantitative Three-Dimensional Analysis of Zygomatico-Maxillary Complex Symmetry |
title_short | A Novel Method for Quantitative Three-Dimensional Analysis of Zygomatico-Maxillary Complex Symmetry |
title_sort | novel method for quantitative three-dimensional analysis of zygomatico-maxillary complex symmetry |
topic | Clinical Studies |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9275855/ https://www.ncbi.nlm.nih.gov/pubmed/34864750 http://dx.doi.org/10.1097/SCS.0000000000008382 |
work_keys_str_mv | AT dekortwwb anovelmethodforquantitativethreedimensionalanalysisofzygomaticomaxillarycomplexsymmetry AT vanhoutwmmt anovelmethodforquantitativethreedimensionalanalysisofzygomaticomaxillarycomplexsymmetry AT tenharkeltc anovelmethodforquantitativethreedimensionalanalysisofzygomaticomaxillarycomplexsymmetry AT vancannem anovelmethodforquantitativethreedimensionalanalysisofzygomaticomaxillarycomplexsymmetry AT rosenbergajwp anovelmethodforquantitativethreedimensionalanalysisofzygomaticomaxillarycomplexsymmetry AT dekortwwb novelmethodforquantitativethreedimensionalanalysisofzygomaticomaxillarycomplexsymmetry AT vanhoutwmmt novelmethodforquantitativethreedimensionalanalysisofzygomaticomaxillarycomplexsymmetry AT tenharkeltc novelmethodforquantitativethreedimensionalanalysisofzygomaticomaxillarycomplexsymmetry AT vancannem novelmethodforquantitativethreedimensionalanalysisofzygomaticomaxillarycomplexsymmetry AT rosenbergajwp novelmethodforquantitativethreedimensionalanalysisofzygomaticomaxillarycomplexsymmetry |