Cargando…

Performance evaluation of a laboratory‐developed light‐initiated chemiluminescence assay for quantification of egg white‐specific IgE

BACKGROUND: Specific IgE (sIgE) testing has become one of the most important tools for diagnosing IgE‐mediated food allergy. Enzyme‐linked immunosorbent assay (ELISA) and dot‐enzyme‐linked immunosorbent assay (Dot‐ELISA) have been used to measure sIgE in clinical widely. Light‐initiated chemilumines...

Descripción completa

Detalles Bibliográficos
Autores principales: Tan, Xin, Zhang, Bei, Zheng, Lisheng, Shi, Hongbin, Liu, Dandan, Sun, Yuanmin, Li, Xue, Li, Huiqiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9279973/
https://www.ncbi.nlm.nih.gov/pubmed/35708142
http://dx.doi.org/10.1002/jcla.24544
_version_ 1784746528604160000
author Tan, Xin
Zhang, Bei
Zheng, Lisheng
Shi, Hongbin
Liu, Dandan
Sun, Yuanmin
Li, Xue
Li, Huiqiang
author_facet Tan, Xin
Zhang, Bei
Zheng, Lisheng
Shi, Hongbin
Liu, Dandan
Sun, Yuanmin
Li, Xue
Li, Huiqiang
author_sort Tan, Xin
collection PubMed
description BACKGROUND: Specific IgE (sIgE) testing has become one of the most important tools for diagnosing IgE‐mediated food allergy. Enzyme‐linked immunosorbent assay (ELISA) and dot‐enzyme‐linked immunosorbent assay (Dot‐ELISA) have been used to measure sIgE in clinical widely. Light‐initiated chemiluminescence assay (LICA) is a new method for measuring allergen‐sIgE. We aimed to establish a LICA method for quantitative detection of egg white‐sIgE and evaluate its performances. METHODS: The best chemibeads coupling method in detecting egg white‐sIgE was selected, and a LICA method for quantitative detection of egg white‐sIgE was established. The precision study was performed according to Clinical and Laboratory Standards Institute (CLSI) EP5‐A2. Detection capability which contains limit of blank (LoB), limit of detection (LoD), and limit of quantitation (LoQ) was evaluated according to National Health Commission of the People's Republic of China (NHC) WS/T 514–2017. Linear range was evaluated according to CLSI EP6‐A. All data were analyzed using SPSS software. RESULTS: Precision contains repeatability and intermediate precision. The CV of repeatability ranged from 2.72% to 7.29%, and the CV of intermediate precision ranged from 4.93% to 8.64%. The LoB, LoD, and LoQ of the assay were 0.000 kUA/L, 0.053 kUA/L, and 0.076 kUA/L. The assay linear range was 0.076–34.125 kU(A)/L (r = 0.9979 ≥ 0.9900). CONCLUSION: This laboratory‐developed LICA method can detect egg white‐sIgE, and performance meets clinical requirements. This method shows rapid turnaround cycles and high sensitivity. It can be used as an alternative method for clinical detection of egg white‐sIgE.
format Online
Article
Text
id pubmed-9279973
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-92799732022-07-15 Performance evaluation of a laboratory‐developed light‐initiated chemiluminescence assay for quantification of egg white‐specific IgE Tan, Xin Zhang, Bei Zheng, Lisheng Shi, Hongbin Liu, Dandan Sun, Yuanmin Li, Xue Li, Huiqiang J Clin Lab Anal Research Articles BACKGROUND: Specific IgE (sIgE) testing has become one of the most important tools for diagnosing IgE‐mediated food allergy. Enzyme‐linked immunosorbent assay (ELISA) and dot‐enzyme‐linked immunosorbent assay (Dot‐ELISA) have been used to measure sIgE in clinical widely. Light‐initiated chemiluminescence assay (LICA) is a new method for measuring allergen‐sIgE. We aimed to establish a LICA method for quantitative detection of egg white‐sIgE and evaluate its performances. METHODS: The best chemibeads coupling method in detecting egg white‐sIgE was selected, and a LICA method for quantitative detection of egg white‐sIgE was established. The precision study was performed according to Clinical and Laboratory Standards Institute (CLSI) EP5‐A2. Detection capability which contains limit of blank (LoB), limit of detection (LoD), and limit of quantitation (LoQ) was evaluated according to National Health Commission of the People's Republic of China (NHC) WS/T 514–2017. Linear range was evaluated according to CLSI EP6‐A. All data were analyzed using SPSS software. RESULTS: Precision contains repeatability and intermediate precision. The CV of repeatability ranged from 2.72% to 7.29%, and the CV of intermediate precision ranged from 4.93% to 8.64%. The LoB, LoD, and LoQ of the assay were 0.000 kUA/L, 0.053 kUA/L, and 0.076 kUA/L. The assay linear range was 0.076–34.125 kU(A)/L (r = 0.9979 ≥ 0.9900). CONCLUSION: This laboratory‐developed LICA method can detect egg white‐sIgE, and performance meets clinical requirements. This method shows rapid turnaround cycles and high sensitivity. It can be used as an alternative method for clinical detection of egg white‐sIgE. John Wiley and Sons Inc. 2022-06-16 /pmc/articles/PMC9279973/ /pubmed/35708142 http://dx.doi.org/10.1002/jcla.24544 Text en © 2022 The Authors. Journal of Clinical Laboratory Analysis published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Research Articles
Tan, Xin
Zhang, Bei
Zheng, Lisheng
Shi, Hongbin
Liu, Dandan
Sun, Yuanmin
Li, Xue
Li, Huiqiang
Performance evaluation of a laboratory‐developed light‐initiated chemiluminescence assay for quantification of egg white‐specific IgE
title Performance evaluation of a laboratory‐developed light‐initiated chemiluminescence assay for quantification of egg white‐specific IgE
title_full Performance evaluation of a laboratory‐developed light‐initiated chemiluminescence assay for quantification of egg white‐specific IgE
title_fullStr Performance evaluation of a laboratory‐developed light‐initiated chemiluminescence assay for quantification of egg white‐specific IgE
title_full_unstemmed Performance evaluation of a laboratory‐developed light‐initiated chemiluminescence assay for quantification of egg white‐specific IgE
title_short Performance evaluation of a laboratory‐developed light‐initiated chemiluminescence assay for quantification of egg white‐specific IgE
title_sort performance evaluation of a laboratory‐developed light‐initiated chemiluminescence assay for quantification of egg white‐specific ige
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9279973/
https://www.ncbi.nlm.nih.gov/pubmed/35708142
http://dx.doi.org/10.1002/jcla.24544
work_keys_str_mv AT tanxin performanceevaluationofalaboratorydevelopedlightinitiatedchemiluminescenceassayforquantificationofeggwhitespecificige
AT zhangbei performanceevaluationofalaboratorydevelopedlightinitiatedchemiluminescenceassayforquantificationofeggwhitespecificige
AT zhenglisheng performanceevaluationofalaboratorydevelopedlightinitiatedchemiluminescenceassayforquantificationofeggwhitespecificige
AT shihongbin performanceevaluationofalaboratorydevelopedlightinitiatedchemiluminescenceassayforquantificationofeggwhitespecificige
AT liudandan performanceevaluationofalaboratorydevelopedlightinitiatedchemiluminescenceassayforquantificationofeggwhitespecificige
AT sunyuanmin performanceevaluationofalaboratorydevelopedlightinitiatedchemiluminescenceassayforquantificationofeggwhitespecificige
AT lixue performanceevaluationofalaboratorydevelopedlightinitiatedchemiluminescenceassayforquantificationofeggwhitespecificige
AT lihuiqiang performanceevaluationofalaboratorydevelopedlightinitiatedchemiluminescenceassayforquantificationofeggwhitespecificige