Cargando…
Less Time Is Less Motion: Analysis of Practical Efficiencies Gained With a Modified Workflow Integrating Planar kV Midimaging With CBCT for Spine Stereotactic Body Radiation Therapy
PURPOSE: Our purpose was to optimize an image guided radiation therapy (IGRT) workflow to achieve practical setup accuracy in spine stereotactic body radiation therapy (SBRT). We assessed the time-saving efficiencies gained from incorporating planar kV midimaging as a surrogate for cone beam compute...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9280020/ https://www.ncbi.nlm.nih.gov/pubmed/35847546 http://dx.doi.org/10.1016/j.adro.2022.100961 |
_version_ | 1784746540071387136 |
---|---|
author | Hu, David Y. Xu, Yiwen Chen, Yu-Hui Khosravi, Marjan Lyatskaya, Yulia Bredfeldt, Jeremy S. Hacker, Fred L. Balboni, Tracy A. Spektor, Alexander Cagney, Daniel Mak, Raymond Huynh, Mai Anh |
author_facet | Hu, David Y. Xu, Yiwen Chen, Yu-Hui Khosravi, Marjan Lyatskaya, Yulia Bredfeldt, Jeremy S. Hacker, Fred L. Balboni, Tracy A. Spektor, Alexander Cagney, Daniel Mak, Raymond Huynh, Mai Anh |
author_sort | Hu, David Y. |
collection | PubMed |
description | PURPOSE: Our purpose was to optimize an image guided radiation therapy (IGRT) workflow to achieve practical setup accuracy in spine stereotactic body radiation therapy (SBRT). We assessed the time-saving efficiencies gained from incorporating planar kV midimaging as a surrogate for cone beam computed tomography (CBCT) for intrafraction motion monitoring. METHODS AND MATERIALS: We selected 5 thoracic spine SBRT patients treated in 5 fractions and analyzed patient shifts captured by a modified IGRT workflow using planar kV midimaging integrated with CBCT to maintain a tolerance of 1 mm and 1°. We determined the frequency at which kV midimaging captured intrafraction motion as validated on repeat CBCT and assessed the potential time and dosimetric advantages of our modified IGRT workflow. RESULTS: Patient motion, detected as out-of-tolerance shifts on planar kV midimaging, occurred during 6 of 25 fractions (24%) and were validated on repeat CBCT 100% of the time. Observed intrafraction absolute shifts (mean ± standard deviation) for the 25 fractions were 0.39 ± 0.21, 0.56 ± 0.22, and 0.45 ± 0.21 mm for lateral-longitude-vertical translations and 0.38 ± 0.12°, 0.32 ± 0.09°, and 0.47 ± 0.14° for pitch-roll-yaw rotation, which if uncorrected, could have significantly affected target coverage and increased spinal cord dose. The average times for pretreatment imaging, midtreatment verification, and total treatment time were 8.94, 2.81, and 16.21 minutes. Our modified IGRT workflow reduced the total number of CBCTs required from 120 to 35 (70%) and imaging dose from 126.2 to 43.4 cGy (65.6%) while maintaining high fidelity for our patient population. CONCLUSIONS: Accurate patient positioning was effectively achieved with use of multiple 2-dimensional-3-dimensional kV images and an average of 1 verification CBCT scan per fraction. Integration of planar kV midimaging can effectively reduce treatment time associated with spine SBRT delivery and minimize the potential dosimetric effect of intrafraction motion on target coverage and spinal cord dose. |
format | Online Article Text |
id | pubmed-9280020 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-92800202022-07-15 Less Time Is Less Motion: Analysis of Practical Efficiencies Gained With a Modified Workflow Integrating Planar kV Midimaging With CBCT for Spine Stereotactic Body Radiation Therapy Hu, David Y. Xu, Yiwen Chen, Yu-Hui Khosravi, Marjan Lyatskaya, Yulia Bredfeldt, Jeremy S. Hacker, Fred L. Balboni, Tracy A. Spektor, Alexander Cagney, Daniel Mak, Raymond Huynh, Mai Anh Adv Radiat Oncol Scientific Article PURPOSE: Our purpose was to optimize an image guided radiation therapy (IGRT) workflow to achieve practical setup accuracy in spine stereotactic body radiation therapy (SBRT). We assessed the time-saving efficiencies gained from incorporating planar kV midimaging as a surrogate for cone beam computed tomography (CBCT) for intrafraction motion monitoring. METHODS AND MATERIALS: We selected 5 thoracic spine SBRT patients treated in 5 fractions and analyzed patient shifts captured by a modified IGRT workflow using planar kV midimaging integrated with CBCT to maintain a tolerance of 1 mm and 1°. We determined the frequency at which kV midimaging captured intrafraction motion as validated on repeat CBCT and assessed the potential time and dosimetric advantages of our modified IGRT workflow. RESULTS: Patient motion, detected as out-of-tolerance shifts on planar kV midimaging, occurred during 6 of 25 fractions (24%) and were validated on repeat CBCT 100% of the time. Observed intrafraction absolute shifts (mean ± standard deviation) for the 25 fractions were 0.39 ± 0.21, 0.56 ± 0.22, and 0.45 ± 0.21 mm for lateral-longitude-vertical translations and 0.38 ± 0.12°, 0.32 ± 0.09°, and 0.47 ± 0.14° for pitch-roll-yaw rotation, which if uncorrected, could have significantly affected target coverage and increased spinal cord dose. The average times for pretreatment imaging, midtreatment verification, and total treatment time were 8.94, 2.81, and 16.21 minutes. Our modified IGRT workflow reduced the total number of CBCTs required from 120 to 35 (70%) and imaging dose from 126.2 to 43.4 cGy (65.6%) while maintaining high fidelity for our patient population. CONCLUSIONS: Accurate patient positioning was effectively achieved with use of multiple 2-dimensional-3-dimensional kV images and an average of 1 verification CBCT scan per fraction. Integration of planar kV midimaging can effectively reduce treatment time associated with spine SBRT delivery and minimize the potential dosimetric effect of intrafraction motion on target coverage and spinal cord dose. Elsevier 2022-04-08 /pmc/articles/PMC9280020/ /pubmed/35847546 http://dx.doi.org/10.1016/j.adro.2022.100961 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Scientific Article Hu, David Y. Xu, Yiwen Chen, Yu-Hui Khosravi, Marjan Lyatskaya, Yulia Bredfeldt, Jeremy S. Hacker, Fred L. Balboni, Tracy A. Spektor, Alexander Cagney, Daniel Mak, Raymond Huynh, Mai Anh Less Time Is Less Motion: Analysis of Practical Efficiencies Gained With a Modified Workflow Integrating Planar kV Midimaging With CBCT for Spine Stereotactic Body Radiation Therapy |
title | Less Time Is Less Motion: Analysis of Practical Efficiencies Gained With a Modified Workflow Integrating Planar kV Midimaging With CBCT for Spine Stereotactic Body Radiation Therapy |
title_full | Less Time Is Less Motion: Analysis of Practical Efficiencies Gained With a Modified Workflow Integrating Planar kV Midimaging With CBCT for Spine Stereotactic Body Radiation Therapy |
title_fullStr | Less Time Is Less Motion: Analysis of Practical Efficiencies Gained With a Modified Workflow Integrating Planar kV Midimaging With CBCT for Spine Stereotactic Body Radiation Therapy |
title_full_unstemmed | Less Time Is Less Motion: Analysis of Practical Efficiencies Gained With a Modified Workflow Integrating Planar kV Midimaging With CBCT for Spine Stereotactic Body Radiation Therapy |
title_short | Less Time Is Less Motion: Analysis of Practical Efficiencies Gained With a Modified Workflow Integrating Planar kV Midimaging With CBCT for Spine Stereotactic Body Radiation Therapy |
title_sort | less time is less motion: analysis of practical efficiencies gained with a modified workflow integrating planar kv midimaging with cbct for spine stereotactic body radiation therapy |
topic | Scientific Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9280020/ https://www.ncbi.nlm.nih.gov/pubmed/35847546 http://dx.doi.org/10.1016/j.adro.2022.100961 |
work_keys_str_mv | AT hudavidy lesstimeislessmotionanalysisofpracticalefficienciesgainedwithamodifiedworkflowintegratingplanarkvmidimagingwithcbctforspinestereotacticbodyradiationtherapy AT xuyiwen lesstimeislessmotionanalysisofpracticalefficienciesgainedwithamodifiedworkflowintegratingplanarkvmidimagingwithcbctforspinestereotacticbodyradiationtherapy AT chenyuhui lesstimeislessmotionanalysisofpracticalefficienciesgainedwithamodifiedworkflowintegratingplanarkvmidimagingwithcbctforspinestereotacticbodyradiationtherapy AT khosravimarjan lesstimeislessmotionanalysisofpracticalefficienciesgainedwithamodifiedworkflowintegratingplanarkvmidimagingwithcbctforspinestereotacticbodyradiationtherapy AT lyatskayayulia lesstimeislessmotionanalysisofpracticalefficienciesgainedwithamodifiedworkflowintegratingplanarkvmidimagingwithcbctforspinestereotacticbodyradiationtherapy AT bredfeldtjeremys lesstimeislessmotionanalysisofpracticalefficienciesgainedwithamodifiedworkflowintegratingplanarkvmidimagingwithcbctforspinestereotacticbodyradiationtherapy AT hackerfredl lesstimeislessmotionanalysisofpracticalefficienciesgainedwithamodifiedworkflowintegratingplanarkvmidimagingwithcbctforspinestereotacticbodyradiationtherapy AT balbonitracya lesstimeislessmotionanalysisofpracticalefficienciesgainedwithamodifiedworkflowintegratingplanarkvmidimagingwithcbctforspinestereotacticbodyradiationtherapy AT spektoralexander lesstimeislessmotionanalysisofpracticalefficienciesgainedwithamodifiedworkflowintegratingplanarkvmidimagingwithcbctforspinestereotacticbodyradiationtherapy AT cagneydaniel lesstimeislessmotionanalysisofpracticalefficienciesgainedwithamodifiedworkflowintegratingplanarkvmidimagingwithcbctforspinestereotacticbodyradiationtherapy AT makraymond lesstimeislessmotionanalysisofpracticalefficienciesgainedwithamodifiedworkflowintegratingplanarkvmidimagingwithcbctforspinestereotacticbodyradiationtherapy AT huynhmaianh lesstimeislessmotionanalysisofpracticalefficienciesgainedwithamodifiedworkflowintegratingplanarkvmidimagingwithcbctforspinestereotacticbodyradiationtherapy |