Cargando…

Reference Values for Point-of-Care Echocardiographic Measurements of Preterm Infants in China

BACKGROUND: Few studies have examined the reference value of the left ventricular structure and function in preterm infants. This study was designed to establish a point-of-care echocardiographic reference range of left ventricular structure and function based on different gestational age, weight, a...

Descripción completa

Detalles Bibliográficos
Autores principales: Lu, Dan-Fang, Tong, Xiao-Mei, Liu, Yun-Feng, Zhang, Hua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9280336/
https://www.ncbi.nlm.nih.gov/pubmed/35844737
http://dx.doi.org/10.3389/fped.2022.894152
_version_ 1784746617221414912
author Lu, Dan-Fang
Tong, Xiao-Mei
Liu, Yun-Feng
Zhang, Hua
author_facet Lu, Dan-Fang
Tong, Xiao-Mei
Liu, Yun-Feng
Zhang, Hua
author_sort Lu, Dan-Fang
collection PubMed
description BACKGROUND: Few studies have examined the reference value of the left ventricular structure and function in preterm infants. This study was designed to establish a point-of-care echocardiographic reference range of left ventricular structure and function based on different gestational age, weight, and body surface area (BSA) for preterm infants within 7 days after birth. METHODS: We retrospectively studied 489 patients with traditional echocardiographic data of left ventricular (LV) M-mode: LV end diastolic dimensions (LVED), LV end systolic dimension (LVES), end-diastolic interventricular septal thickness (IVSd), end diastolic LV posterior wall thickness (LVPWd), left atrial (LA) and aortic root (AO) diameters, and index of LA/AO, LV ejection fraction (LVEF), LV fractional shortening (LVFS), and pulsed wave Doppler: aortic valve flow rate (AV), peak mitral valve flow rate E(MV-E), peak mitral valve flow rate A(MV-A), and MV-E/A. The LV dimensions and the maximum blood flow velocities of the aortic valves and mitral valves according to gestational age, birth weight, and body surface area (BSA) are presented in percentiles tables. Percentile curves of aforesaid four cardiac measurements (LVED, LA diameter (LAD), MV-E, MV-E/A) using the R language Generalized Additive Models for Location, Scale and Shape (GAMLSS) method were developed according to different gestational ages and weights. RESULTS: Measurements of all cardiac dimensions and Doppler maximum velocities of AV, MV-E, and MV-E/A showed a correlation with gestational age, weight, and BSA. LVED, LAD, MV-E, and MV-E/A showed a trend of increasing values with gestational age and weight on the percentile curves. CONCLUSION: The percentile tables and graphs of these point-of-care echocardiographic data can provide reliable reference data for Chinese neonates. Normative values are recommended as a source of reference data for the identification of potentially abnormal echocardiography.
format Online
Article
Text
id pubmed-9280336
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-92803362022-07-15 Reference Values for Point-of-Care Echocardiographic Measurements of Preterm Infants in China Lu, Dan-Fang Tong, Xiao-Mei Liu, Yun-Feng Zhang, Hua Front Pediatr Pediatrics BACKGROUND: Few studies have examined the reference value of the left ventricular structure and function in preterm infants. This study was designed to establish a point-of-care echocardiographic reference range of left ventricular structure and function based on different gestational age, weight, and body surface area (BSA) for preterm infants within 7 days after birth. METHODS: We retrospectively studied 489 patients with traditional echocardiographic data of left ventricular (LV) M-mode: LV end diastolic dimensions (LVED), LV end systolic dimension (LVES), end-diastolic interventricular septal thickness (IVSd), end diastolic LV posterior wall thickness (LVPWd), left atrial (LA) and aortic root (AO) diameters, and index of LA/AO, LV ejection fraction (LVEF), LV fractional shortening (LVFS), and pulsed wave Doppler: aortic valve flow rate (AV), peak mitral valve flow rate E(MV-E), peak mitral valve flow rate A(MV-A), and MV-E/A. The LV dimensions and the maximum blood flow velocities of the aortic valves and mitral valves according to gestational age, birth weight, and body surface area (BSA) are presented in percentiles tables. Percentile curves of aforesaid four cardiac measurements (LVED, LA diameter (LAD), MV-E, MV-E/A) using the R language Generalized Additive Models for Location, Scale and Shape (GAMLSS) method were developed according to different gestational ages and weights. RESULTS: Measurements of all cardiac dimensions and Doppler maximum velocities of AV, MV-E, and MV-E/A showed a correlation with gestational age, weight, and BSA. LVED, LAD, MV-E, and MV-E/A showed a trend of increasing values with gestational age and weight on the percentile curves. CONCLUSION: The percentile tables and graphs of these point-of-care echocardiographic data can provide reliable reference data for Chinese neonates. Normative values are recommended as a source of reference data for the identification of potentially abnormal echocardiography. Frontiers Media S.A. 2022-06-30 /pmc/articles/PMC9280336/ /pubmed/35844737 http://dx.doi.org/10.3389/fped.2022.894152 Text en Copyright © 2022 Lu, Tong, Liu and Zhang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Pediatrics
Lu, Dan-Fang
Tong, Xiao-Mei
Liu, Yun-Feng
Zhang, Hua
Reference Values for Point-of-Care Echocardiographic Measurements of Preterm Infants in China
title Reference Values for Point-of-Care Echocardiographic Measurements of Preterm Infants in China
title_full Reference Values for Point-of-Care Echocardiographic Measurements of Preterm Infants in China
title_fullStr Reference Values for Point-of-Care Echocardiographic Measurements of Preterm Infants in China
title_full_unstemmed Reference Values for Point-of-Care Echocardiographic Measurements of Preterm Infants in China
title_short Reference Values for Point-of-Care Echocardiographic Measurements of Preterm Infants in China
title_sort reference values for point-of-care echocardiographic measurements of preterm infants in china
topic Pediatrics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9280336/
https://www.ncbi.nlm.nih.gov/pubmed/35844737
http://dx.doi.org/10.3389/fped.2022.894152
work_keys_str_mv AT ludanfang referencevaluesforpointofcareechocardiographicmeasurementsofpreterminfantsinchina
AT tongxiaomei referencevaluesforpointofcareechocardiographicmeasurementsofpreterminfantsinchina
AT liuyunfeng referencevaluesforpointofcareechocardiographicmeasurementsofpreterminfantsinchina
AT zhanghua referencevaluesforpointofcareechocardiographicmeasurementsofpreterminfantsinchina