Protocol for a systematic review and meta-analysis of the diagnostic accuracy of artificial intelligence for grading of ophthalmology imaging modalities

BACKGROUND: With the rise of artificial intelligence (AI) in ophthalmology, the need to define its diagnostic accuracy is increasingly important. The review aims to elucidate the diagnostic accuracy of AI algorithms in screening for all ophthalmic conditions in patient care settings that involve dig...

Descripción completa

Detalles Bibliográficos
Autores principales: Cao, Jessica, Chang-Kit, Brittany, Katsnelson, Glen, Far, Parsa Merhraban, Uleryk, Elizabeth, Ogunbameru, Adeteju, Miranda, Rafael N., Felfeli, Tina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9281030/
https://www.ncbi.nlm.nih.gov/pubmed/35831880
http://dx.doi.org/10.1186/s41512-022-00127-9
Descripción
Sumario:BACKGROUND: With the rise of artificial intelligence (AI) in ophthalmology, the need to define its diagnostic accuracy is increasingly important. The review aims to elucidate the diagnostic accuracy of AI algorithms in screening for all ophthalmic conditions in patient care settings that involve digital imaging modalities, using the reference standard of human graders. METHODS: This is a systematic review and meta-analysis. A literature search will be conducted on Ovid MEDLINE, Ovid EMBASE, and Wiley Cochrane CENTRAL from January 1, 2000, to December 20, 2021. Studies will be selected via screening the titles and abstracts, followed by full-text screening. Articles that compare the results of AI-graded ophthalmic images with results from human graders as a reference standard will be included; articles that do not will be excluded. The systematic review software DistillerSR will be used to automate part of the screening process as an adjunct to human reviewers. After the full-text screening, data will be extracted from each study via the categories of study characteristics, patient information, AI methods, intervention, and outcomes. Risk of bias will be scored using Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) by two trained independent reviewers. Disagreements at any step will be addressed by a third adjudicator. The study results will include summary receiver operating characteristic (sROC) curve plots as well as pooled sensitivity and specificity of artificial intelligence for detection of any ophthalmic conditions based on imaging modalities compared to the reference standard. Statistics will be calculated in the R statistical software. DISCUSSION: This study will provide novel insights into the diagnostic accuracy of AI in new domains of ophthalmology that have not been previously studied. The protocol also outlines the use of an AI-based software to assist in article screening, which may serve as a reference for improving the efficiency and accuracy of future large systematic reviews. TRIAL REGISTRATION: PROSPERO, CRD42021274441 SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s41512-022-00127-9.