Effects of alternating heat and cold stimulation at different cooling rates using a wearable thermo device on shoulder muscle stiffness: a cross-over study
BACKGROUND: A small, wearable thermo device that uses Peltier elements for programmed heat and cold stimulation has been developed recently and is expected to be applied in conventional contrast bath therapy. This study was aimed to examine improvements in trapezius muscle hardness and subjective sy...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9281090/ https://www.ncbi.nlm.nih.gov/pubmed/35831832 http://dx.doi.org/10.1186/s12891-022-05623-z |
_version_ | 1784746801361846272 |
---|---|
author | Sawada, Tomonori Okawara, Hiroki Nakashima, Daisuke Iwabuchi, Shuhei Matsumoto, Morio Nakamura, Masaya Nagura, Takeo |
author_facet | Sawada, Tomonori Okawara, Hiroki Nakashima, Daisuke Iwabuchi, Shuhei Matsumoto, Morio Nakamura, Masaya Nagura, Takeo |
author_sort | Sawada, Tomonori |
collection | PubMed |
description | BACKGROUND: A small, wearable thermo device that uses Peltier elements for programmed heat and cold stimulation has been developed recently and is expected to be applied in conventional contrast bath therapy. This study was aimed to examine improvements in trapezius muscle hardness and subjective symptoms resulting from alternating heat and cold stimulation, with different rates of cooling. METHODS: This cross-over study included four conditions. Twenty healthy young male individuals (age, 22.3 ± 4.5 years) participated in this study. These four interventions targeted the unilateral trapezius muscle of the dominant arm after a 15-min typing task. Specifically, heat and cold stimulations were applied at different ratios (the heating/cooling rate of 3:1, 3:2, and 3:3) or not applied. Each intervention was separated by at least one week. Skin temperature at the stimulation area was recorded using a data logger. Outcome measures included muscle hardness (measured using a portable tester) and subjective symptoms (muscle stiffness and fatigue). Each item was assessed at three time points: baseline, after typing, and after the intervention. RESULTS: Two-way analysis of variance with repeated measures found an interaction effect for muscle hardness between four conditions (3:1, 3:2, 3:3, and no) and three time points (p < 0.05). Only in the 3:1 condition were the post-intervention values lower than those after typing (p < 0.01). There was also an interaction effect for subjective muscle stiffness (p < 0.05); the values after the intervention in the 3:1 condition were lower than those after intervention in the no stimulation condition (p < 0.01). There was no significant relationship between changes in muscle hardness and changes in subjective symptoms in the 3:1 condition. CONCLUSIONS: Our results demonstrate that alternating heat and cold stimulations with a different cooling rate could affect the degree of improvement in muscle hardness and subjective symptoms. In particular, the 3:1 condition has the possibility to improved muscle hardness within the condition and subjective muscle stiffness between conditions. TRIAL REGISTRATION: UMIN000040620. Registered 1 June 2020, https://upload.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000046359 SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-022-05623-z. |
format | Online Article Text |
id | pubmed-9281090 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-92810902022-07-15 Effects of alternating heat and cold stimulation at different cooling rates using a wearable thermo device on shoulder muscle stiffness: a cross-over study Sawada, Tomonori Okawara, Hiroki Nakashima, Daisuke Iwabuchi, Shuhei Matsumoto, Morio Nakamura, Masaya Nagura, Takeo BMC Musculoskelet Disord Research BACKGROUND: A small, wearable thermo device that uses Peltier elements for programmed heat and cold stimulation has been developed recently and is expected to be applied in conventional contrast bath therapy. This study was aimed to examine improvements in trapezius muscle hardness and subjective symptoms resulting from alternating heat and cold stimulation, with different rates of cooling. METHODS: This cross-over study included four conditions. Twenty healthy young male individuals (age, 22.3 ± 4.5 years) participated in this study. These four interventions targeted the unilateral trapezius muscle of the dominant arm after a 15-min typing task. Specifically, heat and cold stimulations were applied at different ratios (the heating/cooling rate of 3:1, 3:2, and 3:3) or not applied. Each intervention was separated by at least one week. Skin temperature at the stimulation area was recorded using a data logger. Outcome measures included muscle hardness (measured using a portable tester) and subjective symptoms (muscle stiffness and fatigue). Each item was assessed at three time points: baseline, after typing, and after the intervention. RESULTS: Two-way analysis of variance with repeated measures found an interaction effect for muscle hardness between four conditions (3:1, 3:2, 3:3, and no) and three time points (p < 0.05). Only in the 3:1 condition were the post-intervention values lower than those after typing (p < 0.01). There was also an interaction effect for subjective muscle stiffness (p < 0.05); the values after the intervention in the 3:1 condition were lower than those after intervention in the no stimulation condition (p < 0.01). There was no significant relationship between changes in muscle hardness and changes in subjective symptoms in the 3:1 condition. CONCLUSIONS: Our results demonstrate that alternating heat and cold stimulations with a different cooling rate could affect the degree of improvement in muscle hardness and subjective symptoms. In particular, the 3:1 condition has the possibility to improved muscle hardness within the condition and subjective muscle stiffness between conditions. TRIAL REGISTRATION: UMIN000040620. Registered 1 June 2020, https://upload.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000046359 SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-022-05623-z. BioMed Central 2022-07-14 /pmc/articles/PMC9281090/ /pubmed/35831832 http://dx.doi.org/10.1186/s12891-022-05623-z Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Sawada, Tomonori Okawara, Hiroki Nakashima, Daisuke Iwabuchi, Shuhei Matsumoto, Morio Nakamura, Masaya Nagura, Takeo Effects of alternating heat and cold stimulation at different cooling rates using a wearable thermo device on shoulder muscle stiffness: a cross-over study |
title | Effects of alternating heat and cold stimulation at different cooling rates using a wearable thermo device on shoulder muscle stiffness: a cross-over study |
title_full | Effects of alternating heat and cold stimulation at different cooling rates using a wearable thermo device on shoulder muscle stiffness: a cross-over study |
title_fullStr | Effects of alternating heat and cold stimulation at different cooling rates using a wearable thermo device on shoulder muscle stiffness: a cross-over study |
title_full_unstemmed | Effects of alternating heat and cold stimulation at different cooling rates using a wearable thermo device on shoulder muscle stiffness: a cross-over study |
title_short | Effects of alternating heat and cold stimulation at different cooling rates using a wearable thermo device on shoulder muscle stiffness: a cross-over study |
title_sort | effects of alternating heat and cold stimulation at different cooling rates using a wearable thermo device on shoulder muscle stiffness: a cross-over study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9281090/ https://www.ncbi.nlm.nih.gov/pubmed/35831832 http://dx.doi.org/10.1186/s12891-022-05623-z |
work_keys_str_mv | AT sawadatomonori effectsofalternatingheatandcoldstimulationatdifferentcoolingratesusingawearablethermodeviceonshouldermusclestiffnessacrossoverstudy AT okawarahiroki effectsofalternatingheatandcoldstimulationatdifferentcoolingratesusingawearablethermodeviceonshouldermusclestiffnessacrossoverstudy AT nakashimadaisuke effectsofalternatingheatandcoldstimulationatdifferentcoolingratesusingawearablethermodeviceonshouldermusclestiffnessacrossoverstudy AT iwabuchishuhei effectsofalternatingheatandcoldstimulationatdifferentcoolingratesusingawearablethermodeviceonshouldermusclestiffnessacrossoverstudy AT matsumotomorio effectsofalternatingheatandcoldstimulationatdifferentcoolingratesusingawearablethermodeviceonshouldermusclestiffnessacrossoverstudy AT nakamuramasaya effectsofalternatingheatandcoldstimulationatdifferentcoolingratesusingawearablethermodeviceonshouldermusclestiffnessacrossoverstudy AT naguratakeo effectsofalternatingheatandcoldstimulationatdifferentcoolingratesusingawearablethermodeviceonshouldermusclestiffnessacrossoverstudy |