Cargando…
Comparative analysis of a presbyopia-correcting intraocular lens that combines extended depth-of-focus and bifocal profiles with a standard monofocal intraocular lens
BACKGROUND: Recently, a new presbyopia-correcting intraocular lens (IOL) that combines extended depth-of-focus and bifocal profiles (ZFR00: Tecnis® Synergy®, Johnson & Johnson Vision, Santa Ana, CA, USA) has been established and several studies have been reported. We attempted to compare the per...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9284875/ https://www.ncbi.nlm.nih.gov/pubmed/35836144 http://dx.doi.org/10.1186/s12886-022-02516-6 |
Sumario: | BACKGROUND: Recently, a new presbyopia-correcting intraocular lens (IOL) that combines extended depth-of-focus and bifocal profiles (ZFR00: Tecnis® Synergy®, Johnson & Johnson Vision, Santa Ana, CA, USA) has been established and several studies have been reported. We attempted to compare the performance with a standard IOL (ZCB00: Tecnis® monofocal, Johnson & Johnson Vision, Santa Ana, CA, USA) manufactured using the same material from the same company, which has been extensively used worldwide. METHODS: The medical records of patients undergoing cataract surgery with ZCB00 or ZFR00 implantation between March 2021 and September 2021 and with available 3-month visit data were reviewed. Uncorrected near, intermediate, and distance visual acuity (VA), corrected distance VA, and optical quality were the main outcome measures. RESULTS: This study included forty-six patients (64 eyes), with twenty-one patients (32 eyes) implanted with ZCB00 and twenty-five patients (32 eyes) implanted with ZFR00. The average age of the patients was 66.0 ± 10.1 (range: 40 to 82) and 65.1 ± 4.7 (range: 59 to 77) years in the ZCB00 and ZFR00 groups, respectively. The preoperative characteristics did not differ significantly between the two groups. Compared to the ZCB00 group, the ZFR00 group demonstrated significantly superior intermediate and near VA (p < 0.001) at 3 months postoperatively. The ZFR00 group showed significantly lower objective measured optical quality than that in the ZCB00 group. CONCLUSIONS: The ZFR00 exhibited a continuous range of vision and a smooth defocus curve, while the ZCB00 provided superior objective optical quality. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-022-02516-6. |
---|