Cargando…
The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis
BACKGROUND: Xen is a device for minimally invasive glaucoma surgery, and is used to treat POAG, pseudoexfoliative or pigmentary glaucoma, as well as refractory glaucoma. The efficacy of XEN in treating glaucoma remains to be confirmed and clarified. Hence, we conducted a systematic review and meta-a...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9284889/ https://www.ncbi.nlm.nih.gov/pubmed/35836197 http://dx.doi.org/10.1186/s12886-022-02502-y |
_version_ | 1784747663172829184 |
---|---|
author | Yang, Xiang Zhao, Yang Zhong, Yu Duan, Xuanchu |
author_facet | Yang, Xiang Zhao, Yang Zhong, Yu Duan, Xuanchu |
author_sort | Yang, Xiang |
collection | PubMed |
description | BACKGROUND: Xen is a device for minimally invasive glaucoma surgery, and is used to treat POAG, pseudoexfoliative or pigmentary glaucoma, as well as refractory glaucoma. The efficacy of XEN in treating glaucoma remains to be confirmed and clarified. Hence, we conducted a systematic review and meta-analysis to examine the efficacy and associated complication of XEN implantations. METHODS: We conducted a literature search in PubMed, EMBASE, the Cochrane Library of Systematic Reviews, Web of Science, China National Knowledge Infrastructure, WanFang and SinoMed databases to identify studies, published before May 15, 2021, which evaluated XEN in glaucoma, and parameters for measurements included intra-ocular pressure (IOP), number of anti-glaucoma medications (NOAM), and bleb needling rate. We compared the measurements of XEN-only procedure between phaco-XEN and trabeculectomy, and we also did sub-analysis based on time points, glaucoma types, ethnics, etc. Sensitivity analyses and publication bias were conducted for evaluating bias.This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA 2020) reporting guideline. RESULTS: We identified 78 eligible studies, analysis revealed obvious IOP reduction after XEN stent implantation (SMD: 1.69, 95% CI 1.52 to 1.86, p value < 0.001) and NOAM reduction (SMD: 2.11, 95% CI 1.84 to 2.38, p value < 0.001). Sub-analysis showed no significant difference with respect to time points, ethnicities, and economic status. No significant difference was found between XEN treatment effect on POAG and PEXG eyes and between pseudo-phakic and phakic eyes. Also no significant difference was found between XEN and phaco-XEN surgery in terms of IOP after surgery (SMD: -0.01, 95% CI -0.09 to 0.08, p value 0.894). However, NOAM (after publication bias correction) and bleb needling rate (RR: 1.45, 95% CI 1.06to 1.99, p value 0.019) were lower in phaco-XEN group compared to XEN only group. Compared to trabeculectomy, XEN implantation had similar after-surgery IOP, however bleb needling rate (RR: 2.42, 95% CI 1.33 to 4.43, p value 0.004) was higher. CONCLUSION: Our results confirmed that XEN is effective in lowering both IOP and NOAM till 48 months after surgery. It is noteworthy that XEN implantation leads to higher needling rate, compared to phaco-XEN or trabeculectomy. Further research, studying complications of XEN on non-European ethnicities, especially on Asian, are in urgent need before XEN is widely applied. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-022-02502-y. |
format | Online Article Text |
id | pubmed-9284889 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-92848892022-07-16 The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis Yang, Xiang Zhao, Yang Zhong, Yu Duan, Xuanchu BMC Ophthalmol Research BACKGROUND: Xen is a device for minimally invasive glaucoma surgery, and is used to treat POAG, pseudoexfoliative or pigmentary glaucoma, as well as refractory glaucoma. The efficacy of XEN in treating glaucoma remains to be confirmed and clarified. Hence, we conducted a systematic review and meta-analysis to examine the efficacy and associated complication of XEN implantations. METHODS: We conducted a literature search in PubMed, EMBASE, the Cochrane Library of Systematic Reviews, Web of Science, China National Knowledge Infrastructure, WanFang and SinoMed databases to identify studies, published before May 15, 2021, which evaluated XEN in glaucoma, and parameters for measurements included intra-ocular pressure (IOP), number of anti-glaucoma medications (NOAM), and bleb needling rate. We compared the measurements of XEN-only procedure between phaco-XEN and trabeculectomy, and we also did sub-analysis based on time points, glaucoma types, ethnics, etc. Sensitivity analyses and publication bias were conducted for evaluating bias.This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA 2020) reporting guideline. RESULTS: We identified 78 eligible studies, analysis revealed obvious IOP reduction after XEN stent implantation (SMD: 1.69, 95% CI 1.52 to 1.86, p value < 0.001) and NOAM reduction (SMD: 2.11, 95% CI 1.84 to 2.38, p value < 0.001). Sub-analysis showed no significant difference with respect to time points, ethnicities, and economic status. No significant difference was found between XEN treatment effect on POAG and PEXG eyes and between pseudo-phakic and phakic eyes. Also no significant difference was found between XEN and phaco-XEN surgery in terms of IOP after surgery (SMD: -0.01, 95% CI -0.09 to 0.08, p value 0.894). However, NOAM (after publication bias correction) and bleb needling rate (RR: 1.45, 95% CI 1.06to 1.99, p value 0.019) were lower in phaco-XEN group compared to XEN only group. Compared to trabeculectomy, XEN implantation had similar after-surgery IOP, however bleb needling rate (RR: 2.42, 95% CI 1.33 to 4.43, p value 0.004) was higher. CONCLUSION: Our results confirmed that XEN is effective in lowering both IOP and NOAM till 48 months after surgery. It is noteworthy that XEN implantation leads to higher needling rate, compared to phaco-XEN or trabeculectomy. Further research, studying complications of XEN on non-European ethnicities, especially on Asian, are in urgent need before XEN is widely applied. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-022-02502-y. BioMed Central 2022-07-15 /pmc/articles/PMC9284889/ /pubmed/35836197 http://dx.doi.org/10.1186/s12886-022-02502-y Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Yang, Xiang Zhao, Yang Zhong, Yu Duan, Xuanchu The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis |
title | The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis |
title_full | The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis |
title_fullStr | The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis |
title_full_unstemmed | The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis |
title_short | The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis |
title_sort | efficacy of xen gel stent implantation in glaucoma: a systematic review and meta-analysis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9284889/ https://www.ncbi.nlm.nih.gov/pubmed/35836197 http://dx.doi.org/10.1186/s12886-022-02502-y |
work_keys_str_mv | AT yangxiang theefficacyofxengelstentimplantationinglaucomaasystematicreviewandmetaanalysis AT zhaoyang theefficacyofxengelstentimplantationinglaucomaasystematicreviewandmetaanalysis AT zhongyu theefficacyofxengelstentimplantationinglaucomaasystematicreviewandmetaanalysis AT duanxuanchu theefficacyofxengelstentimplantationinglaucomaasystematicreviewandmetaanalysis AT yangxiang efficacyofxengelstentimplantationinglaucomaasystematicreviewandmetaanalysis AT zhaoyang efficacyofxengelstentimplantationinglaucomaasystematicreviewandmetaanalysis AT zhongyu efficacyofxengelstentimplantationinglaucomaasystematicreviewandmetaanalysis AT duanxuanchu efficacyofxengelstentimplantationinglaucomaasystematicreviewandmetaanalysis |