Cargando…

Effects of control temperature, ablation time, and background tissue in radiofrequency ablation of osteoid osteoma: A computer modeling study

To study the effects of the control temperature, ablation time, and the background tissue surrounding the tumor on the size of the ablation zone on radiofrequency ablation (RFA) of osteoid osteoma (OO). Finite element models of non‐cooled temperature‐controlled RFA of typical OOs were developed to d...

Descripción completa

Detalles Bibliográficos
Autores principales: Rivas, Ricardo, Hijlkema, Rudy B., Cornelissen, Ludo J., Kwee, Thomas C., Jutte, Paul C., van Ooijen, Peter M. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9285497/
https://www.ncbi.nlm.nih.gov/pubmed/34313015
http://dx.doi.org/10.1002/cnm.3512
_version_ 1784747795494731776
author Rivas, Ricardo
Hijlkema, Rudy B.
Cornelissen, Ludo J.
Kwee, Thomas C.
Jutte, Paul C.
van Ooijen, Peter M. A.
author_facet Rivas, Ricardo
Hijlkema, Rudy B.
Cornelissen, Ludo J.
Kwee, Thomas C.
Jutte, Paul C.
van Ooijen, Peter M. A.
author_sort Rivas, Ricardo
collection PubMed
description To study the effects of the control temperature, ablation time, and the background tissue surrounding the tumor on the size of the ablation zone on radiofrequency ablation (RFA) of osteoid osteoma (OO). Finite element models of non‐cooled temperature‐controlled RFA of typical OOs were developed to determine the resulting ablation radius at control temperatures of 70, 80, and 90°C. Three different geometries were used, mimicking common cases of OO. The ablation radius was obtained by using the Arrhenius equation to determine cell viability. Ablation radii were larger for higher temperatures and also increased with time. All geometries and control temperatures tested had ablation radii larger than the tumor. The ablation radius developed rapidly in the first few minutes for all geometries and control temperatures tested, developing slowly towards the end of the ablation. Resistive heating and the temperature distribution showed differences depending on background tissue properties, resulting in differences in the ablation radius on each geometry. The ablation radius has a clear dependency not only on the properties of the tumor but also on the background tissue. Lower background tissue's electrical conductivity and blood perfusion rates seem to result in larger ablation zones. The differences observed between the different geometries suggest the need for patient‐specific planning, as the anatomical variations could cause significantly different outcomes where models like the one here presented could help to guarantee safe and successful tumor ablations.
format Online
Article
Text
id pubmed-9285497
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-92854972022-07-18 Effects of control temperature, ablation time, and background tissue in radiofrequency ablation of osteoid osteoma: A computer modeling study Rivas, Ricardo Hijlkema, Rudy B. Cornelissen, Ludo J. Kwee, Thomas C. Jutte, Paul C. van Ooijen, Peter M. A. Int J Numer Method Biomed Eng Research Article ‐ Applications To study the effects of the control temperature, ablation time, and the background tissue surrounding the tumor on the size of the ablation zone on radiofrequency ablation (RFA) of osteoid osteoma (OO). Finite element models of non‐cooled temperature‐controlled RFA of typical OOs were developed to determine the resulting ablation radius at control temperatures of 70, 80, and 90°C. Three different geometries were used, mimicking common cases of OO. The ablation radius was obtained by using the Arrhenius equation to determine cell viability. Ablation radii were larger for higher temperatures and also increased with time. All geometries and control temperatures tested had ablation radii larger than the tumor. The ablation radius developed rapidly in the first few minutes for all geometries and control temperatures tested, developing slowly towards the end of the ablation. Resistive heating and the temperature distribution showed differences depending on background tissue properties, resulting in differences in the ablation radius on each geometry. The ablation radius has a clear dependency not only on the properties of the tumor but also on the background tissue. Lower background tissue's electrical conductivity and blood perfusion rates seem to result in larger ablation zones. The differences observed between the different geometries suggest the need for patient‐specific planning, as the anatomical variations could cause significantly different outcomes where models like the one here presented could help to guarantee safe and successful tumor ablations. John Wiley & Sons, Inc. 2021-08-08 2021-09 /pmc/articles/PMC9285497/ /pubmed/34313015 http://dx.doi.org/10.1002/cnm.3512 Text en © 2021 The Authors. International Journal for Numerical Methods in Biomedical Engineering published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article ‐ Applications
Rivas, Ricardo
Hijlkema, Rudy B.
Cornelissen, Ludo J.
Kwee, Thomas C.
Jutte, Paul C.
van Ooijen, Peter M. A.
Effects of control temperature, ablation time, and background tissue in radiofrequency ablation of osteoid osteoma: A computer modeling study
title Effects of control temperature, ablation time, and background tissue in radiofrequency ablation of osteoid osteoma: A computer modeling study
title_full Effects of control temperature, ablation time, and background tissue in radiofrequency ablation of osteoid osteoma: A computer modeling study
title_fullStr Effects of control temperature, ablation time, and background tissue in radiofrequency ablation of osteoid osteoma: A computer modeling study
title_full_unstemmed Effects of control temperature, ablation time, and background tissue in radiofrequency ablation of osteoid osteoma: A computer modeling study
title_short Effects of control temperature, ablation time, and background tissue in radiofrequency ablation of osteoid osteoma: A computer modeling study
title_sort effects of control temperature, ablation time, and background tissue in radiofrequency ablation of osteoid osteoma: a computer modeling study
topic Research Article ‐ Applications
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9285497/
https://www.ncbi.nlm.nih.gov/pubmed/34313015
http://dx.doi.org/10.1002/cnm.3512
work_keys_str_mv AT rivasricardo effectsofcontroltemperatureablationtimeandbackgroundtissueinradiofrequencyablationofosteoidosteomaacomputermodelingstudy
AT hijlkemarudyb effectsofcontroltemperatureablationtimeandbackgroundtissueinradiofrequencyablationofosteoidosteomaacomputermodelingstudy
AT cornelissenludoj effectsofcontroltemperatureablationtimeandbackgroundtissueinradiofrequencyablationofosteoidosteomaacomputermodelingstudy
AT kweethomasc effectsofcontroltemperatureablationtimeandbackgroundtissueinradiofrequencyablationofosteoidosteomaacomputermodelingstudy
AT juttepaulc effectsofcontroltemperatureablationtimeandbackgroundtissueinradiofrequencyablationofosteoidosteomaacomputermodelingstudy
AT vanooijenpeterma effectsofcontroltemperatureablationtimeandbackgroundtissueinradiofrequencyablationofosteoidosteomaacomputermodelingstudy