Cargando…

Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS

A novel MS‐based analytical method for simultaneous analysis of the antiviral drugs acyclovir, its metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum is described. These antiviral drugs are active against herpes virus infections. Acyclovir and penciclovir are regar...

Descripción completa

Detalles Bibliográficos
Autores principales: Ärlemalm, Andreas, Helldén, Anders, Karlsson, Louise, Carlsson, Björn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9285573/
https://www.ncbi.nlm.nih.gov/pubmed/34981553
http://dx.doi.org/10.1002/bmc.5315
_version_ 1784747814780141568
author Ärlemalm, Andreas
Helldén, Anders
Karlsson, Louise
Carlsson, Björn
author_facet Ärlemalm, Andreas
Helldén, Anders
Karlsson, Louise
Carlsson, Björn
author_sort Ärlemalm, Andreas
collection PubMed
description A novel MS‐based analytical method for simultaneous analysis of the antiviral drugs acyclovir, its metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum is described. These antiviral drugs are active against herpes virus infections. Acyclovir and penciclovir are regarded as safe and effective medicines with mild side effects such as headache and gastrointestinal discomfort, and ganciclovir is regarded as more toxic and is known to cause, for example, bone marrow suppression. Acyclovir’s main metabolite 9‐carboxymethoxymethylguanine is a presumptive neurotoxin and should be monitored in patients with impaired renal function or in cases with neurotoxic symptoms. A sample was prepared using protein precipitation with 1% formic acid in methanol containing isotopically labeled internal standard. Chromatographic separation on a biphenyl column and mass spectrometric detection were performed in multiple reaction monitoring (MRM) mode on a Xevo TQ‐S micro with ESI in positive ion mode, within 3 min. Inter‐day assay accuracies for the quality controls varied between 95 and 104% and intra‐day assay between 93 and 105%. Inter‐day and intra‐day assay imprecision for the quality controls ranged between 1.4 and 4.2% and 1.7 and 6.5% respectively. The lower limit of quantification for all four substances was 0.156 μmol/L. It is an accurate and reproducible method for therapeutic drug monitoring.
format Online
Article
Text
id pubmed-9285573
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-92855732022-07-18 Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS Ärlemalm, Andreas Helldén, Anders Karlsson, Louise Carlsson, Björn Biomed Chromatogr Research Articles A novel MS‐based analytical method for simultaneous analysis of the antiviral drugs acyclovir, its metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum is described. These antiviral drugs are active against herpes virus infections. Acyclovir and penciclovir are regarded as safe and effective medicines with mild side effects such as headache and gastrointestinal discomfort, and ganciclovir is regarded as more toxic and is known to cause, for example, bone marrow suppression. Acyclovir’s main metabolite 9‐carboxymethoxymethylguanine is a presumptive neurotoxin and should be monitored in patients with impaired renal function or in cases with neurotoxic symptoms. A sample was prepared using protein precipitation with 1% formic acid in methanol containing isotopically labeled internal standard. Chromatographic separation on a biphenyl column and mass spectrometric detection were performed in multiple reaction monitoring (MRM) mode on a Xevo TQ‐S micro with ESI in positive ion mode, within 3 min. Inter‐day assay accuracies for the quality controls varied between 95 and 104% and intra‐day assay between 93 and 105%. Inter‐day and intra‐day assay imprecision for the quality controls ranged between 1.4 and 4.2% and 1.7 and 6.5% respectively. The lower limit of quantification for all four substances was 0.156 μmol/L. It is an accurate and reproducible method for therapeutic drug monitoring. John Wiley and Sons Inc. 2022-01-28 2022-04 /pmc/articles/PMC9285573/ /pubmed/34981553 http://dx.doi.org/10.1002/bmc.5315 Text en © 2022 The Authors. Biomedical Chromatography published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Research Articles
Ärlemalm, Andreas
Helldén, Anders
Karlsson, Louise
Carlsson, Björn
Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS
title Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS
title_full Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS
title_fullStr Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS
title_full_unstemmed Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS
title_short Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS
title_sort rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using lc–ms/ms
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9285573/
https://www.ncbi.nlm.nih.gov/pubmed/34981553
http://dx.doi.org/10.1002/bmc.5315
work_keys_str_mv AT arlemalmandreas rapiddeterminationofacycloviritsmainmetabolite9carboxymethoxymethylguanineganciclovirandpenciclovirinhumanserumusinglcmsms
AT helldenanders rapiddeterminationofacycloviritsmainmetabolite9carboxymethoxymethylguanineganciclovirandpenciclovirinhumanserumusinglcmsms
AT karlssonlouise rapiddeterminationofacycloviritsmainmetabolite9carboxymethoxymethylguanineganciclovirandpenciclovirinhumanserumusinglcmsms
AT carlssonbjorn rapiddeterminationofacycloviritsmainmetabolite9carboxymethoxymethylguanineganciclovirandpenciclovirinhumanserumusinglcmsms