Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS
A novel MS‐based analytical method for simultaneous analysis of the antiviral drugs acyclovir, its metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum is described. These antiviral drugs are active against herpes virus infections. Acyclovir and penciclovir are regar...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9285573/ https://www.ncbi.nlm.nih.gov/pubmed/34981553 http://dx.doi.org/10.1002/bmc.5315 |
_version_ | 1784747814780141568 |
---|---|
author | Ärlemalm, Andreas Helldén, Anders Karlsson, Louise Carlsson, Björn |
author_facet | Ärlemalm, Andreas Helldén, Anders Karlsson, Louise Carlsson, Björn |
author_sort | Ärlemalm, Andreas |
collection | PubMed |
description | A novel MS‐based analytical method for simultaneous analysis of the antiviral drugs acyclovir, its metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum is described. These antiviral drugs are active against herpes virus infections. Acyclovir and penciclovir are regarded as safe and effective medicines with mild side effects such as headache and gastrointestinal discomfort, and ganciclovir is regarded as more toxic and is known to cause, for example, bone marrow suppression. Acyclovir’s main metabolite 9‐carboxymethoxymethylguanine is a presumptive neurotoxin and should be monitored in patients with impaired renal function or in cases with neurotoxic symptoms. A sample was prepared using protein precipitation with 1% formic acid in methanol containing isotopically labeled internal standard. Chromatographic separation on a biphenyl column and mass spectrometric detection were performed in multiple reaction monitoring (MRM) mode on a Xevo TQ‐S micro with ESI in positive ion mode, within 3 min. Inter‐day assay accuracies for the quality controls varied between 95 and 104% and intra‐day assay between 93 and 105%. Inter‐day and intra‐day assay imprecision for the quality controls ranged between 1.4 and 4.2% and 1.7 and 6.5% respectively. The lower limit of quantification for all four substances was 0.156 μmol/L. It is an accurate and reproducible method for therapeutic drug monitoring. |
format | Online Article Text |
id | pubmed-9285573 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-92855732022-07-18 Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS Ärlemalm, Andreas Helldén, Anders Karlsson, Louise Carlsson, Björn Biomed Chromatogr Research Articles A novel MS‐based analytical method for simultaneous analysis of the antiviral drugs acyclovir, its metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum is described. These antiviral drugs are active against herpes virus infections. Acyclovir and penciclovir are regarded as safe and effective medicines with mild side effects such as headache and gastrointestinal discomfort, and ganciclovir is regarded as more toxic and is known to cause, for example, bone marrow suppression. Acyclovir’s main metabolite 9‐carboxymethoxymethylguanine is a presumptive neurotoxin and should be monitored in patients with impaired renal function or in cases with neurotoxic symptoms. A sample was prepared using protein precipitation with 1% formic acid in methanol containing isotopically labeled internal standard. Chromatographic separation on a biphenyl column and mass spectrometric detection were performed in multiple reaction monitoring (MRM) mode on a Xevo TQ‐S micro with ESI in positive ion mode, within 3 min. Inter‐day assay accuracies for the quality controls varied between 95 and 104% and intra‐day assay between 93 and 105%. Inter‐day and intra‐day assay imprecision for the quality controls ranged between 1.4 and 4.2% and 1.7 and 6.5% respectively. The lower limit of quantification for all four substances was 0.156 μmol/L. It is an accurate and reproducible method for therapeutic drug monitoring. John Wiley and Sons Inc. 2022-01-28 2022-04 /pmc/articles/PMC9285573/ /pubmed/34981553 http://dx.doi.org/10.1002/bmc.5315 Text en © 2022 The Authors. Biomedical Chromatography published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Research Articles Ärlemalm, Andreas Helldén, Anders Karlsson, Louise Carlsson, Björn Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS |
title | Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS |
title_full | Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS |
title_fullStr | Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS |
title_full_unstemmed | Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS |
title_short | Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MS |
title_sort | rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using lc–ms/ms |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9285573/ https://www.ncbi.nlm.nih.gov/pubmed/34981553 http://dx.doi.org/10.1002/bmc.5315 |
work_keys_str_mv | AT arlemalmandreas rapiddeterminationofacycloviritsmainmetabolite9carboxymethoxymethylguanineganciclovirandpenciclovirinhumanserumusinglcmsms AT helldenanders rapiddeterminationofacycloviritsmainmetabolite9carboxymethoxymethylguanineganciclovirandpenciclovirinhumanserumusinglcmsms AT karlssonlouise rapiddeterminationofacycloviritsmainmetabolite9carboxymethoxymethylguanineganciclovirandpenciclovirinhumanserumusinglcmsms AT carlssonbjorn rapiddeterminationofacycloviritsmainmetabolite9carboxymethoxymethylguanineganciclovirandpenciclovirinhumanserumusinglcmsms |