Cargando…

Comparison of Diagnostic Ability of Conventional Film and Storage Phosphor Plate in Detecting Proximal Caries with Direct Measurements by Stereomicroscope: A Diagnostic Test Evaluation

BACKGROUND: Radiography plays an important role in detection of interproximal caries. The aim of study is to compare diagnostic ability of conventional film and photostimulable phosphor (PSP) with direct measurement using stereomicroscope in detecting proximal caries. METHODOLOGY: In this descriptiv...

Descripción completa

Detalles Bibliográficos
Autores principales: Vijayan, Aswathy Kallaliel, Jo, Shiana, Mathew, Benila, Vidyadharan, Mathew, Nair, Aparna M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9285835/
https://www.ncbi.nlm.nih.gov/pubmed/35846590
http://dx.doi.org/10.4103/ccd.ccd_858_20
_version_ 1784747873373519872
author Vijayan, Aswathy Kallaliel
Jo, Shiana
Mathew, Benila
Vidyadharan, Mathew
Nair, Aparna M.
author_facet Vijayan, Aswathy Kallaliel
Jo, Shiana
Mathew, Benila
Vidyadharan, Mathew
Nair, Aparna M.
author_sort Vijayan, Aswathy Kallaliel
collection PubMed
description BACKGROUND: Radiography plays an important role in detection of interproximal caries. The aim of study is to compare diagnostic ability of conventional film and photostimulable phosphor (PSP) with direct measurement using stereomicroscope in detecting proximal caries. METHODOLOGY: In this descriptive study – diagnostic test evaluation, 200 proximal surfaces of 100 extracted human posterior teeth were radiographed with dental X-ray unit. Evaluation of conventional and digital radiographs was performed twice by three observers. Carious lesions were classified based on a four-point scale (R0–R3) suggested by Abesi et al. Weighted kappa coefficients were calculated to assess intra- and interobserver agreement for each image set. Indices of diagnostic ability calculation were based on the first readings of the three observers. The scores were compared with the histological gold standard using receiver operating characteristic (ROC) analysis to evaluate diagnostic ability. RESULTS: Intraobserver kappa coefficients calculated for each observer for each method of detecting caries ranged from 0.914 to 0.956. Interobserver kappa coefficients for each image set ranged from 0.8788 to 0.9583. The sensitivity and specificity of film for the first observer were 77.5% and 78.3% and for PSP were 77.5% and 80%, respectively. ROC analysis revealed that there were no statistically significant results (P > 0.05) between Az values for the two detection methods. CONCLUSION: PSP plate should be preferred over conventional films in detecting cavitated proximal caries. Further studies with more noncavitated proximal surfaces are required to conclusively establish the diagnostic ability of PSP over conventional film.
format Online
Article
Text
id pubmed-9285835
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-92858352022-07-16 Comparison of Diagnostic Ability of Conventional Film and Storage Phosphor Plate in Detecting Proximal Caries with Direct Measurements by Stereomicroscope: A Diagnostic Test Evaluation Vijayan, Aswathy Kallaliel Jo, Shiana Mathew, Benila Vidyadharan, Mathew Nair, Aparna M. Contemp Clin Dent Original Article BACKGROUND: Radiography plays an important role in detection of interproximal caries. The aim of study is to compare diagnostic ability of conventional film and photostimulable phosphor (PSP) with direct measurement using stereomicroscope in detecting proximal caries. METHODOLOGY: In this descriptive study – diagnostic test evaluation, 200 proximal surfaces of 100 extracted human posterior teeth were radiographed with dental X-ray unit. Evaluation of conventional and digital radiographs was performed twice by three observers. Carious lesions were classified based on a four-point scale (R0–R3) suggested by Abesi et al. Weighted kappa coefficients were calculated to assess intra- and interobserver agreement for each image set. Indices of diagnostic ability calculation were based on the first readings of the three observers. The scores were compared with the histological gold standard using receiver operating characteristic (ROC) analysis to evaluate diagnostic ability. RESULTS: Intraobserver kappa coefficients calculated for each observer for each method of detecting caries ranged from 0.914 to 0.956. Interobserver kappa coefficients for each image set ranged from 0.8788 to 0.9583. The sensitivity and specificity of film for the first observer were 77.5% and 78.3% and for PSP were 77.5% and 80%, respectively. ROC analysis revealed that there were no statistically significant results (P > 0.05) between Az values for the two detection methods. CONCLUSION: PSP plate should be preferred over conventional films in detecting cavitated proximal caries. Further studies with more noncavitated proximal surfaces are required to conclusively establish the diagnostic ability of PSP over conventional film. Wolters Kluwer - Medknow 2022 2022-06-21 /pmc/articles/PMC9285835/ /pubmed/35846590 http://dx.doi.org/10.4103/ccd.ccd_858_20 Text en Copyright: © 2022 Contemporary Clinical Dentistry https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Vijayan, Aswathy Kallaliel
Jo, Shiana
Mathew, Benila
Vidyadharan, Mathew
Nair, Aparna M.
Comparison of Diagnostic Ability of Conventional Film and Storage Phosphor Plate in Detecting Proximal Caries with Direct Measurements by Stereomicroscope: A Diagnostic Test Evaluation
title Comparison of Diagnostic Ability of Conventional Film and Storage Phosphor Plate in Detecting Proximal Caries with Direct Measurements by Stereomicroscope: A Diagnostic Test Evaluation
title_full Comparison of Diagnostic Ability of Conventional Film and Storage Phosphor Plate in Detecting Proximal Caries with Direct Measurements by Stereomicroscope: A Diagnostic Test Evaluation
title_fullStr Comparison of Diagnostic Ability of Conventional Film and Storage Phosphor Plate in Detecting Proximal Caries with Direct Measurements by Stereomicroscope: A Diagnostic Test Evaluation
title_full_unstemmed Comparison of Diagnostic Ability of Conventional Film and Storage Phosphor Plate in Detecting Proximal Caries with Direct Measurements by Stereomicroscope: A Diagnostic Test Evaluation
title_short Comparison of Diagnostic Ability of Conventional Film and Storage Phosphor Plate in Detecting Proximal Caries with Direct Measurements by Stereomicroscope: A Diagnostic Test Evaluation
title_sort comparison of diagnostic ability of conventional film and storage phosphor plate in detecting proximal caries with direct measurements by stereomicroscope: a diagnostic test evaluation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9285835/
https://www.ncbi.nlm.nih.gov/pubmed/35846590
http://dx.doi.org/10.4103/ccd.ccd_858_20
work_keys_str_mv AT vijayanaswathykallaliel comparisonofdiagnosticabilityofconventionalfilmandstoragephosphorplateindetectingproximalcarieswithdirectmeasurementsbystereomicroscopeadiagnostictestevaluation
AT joshiana comparisonofdiagnosticabilityofconventionalfilmandstoragephosphorplateindetectingproximalcarieswithdirectmeasurementsbystereomicroscopeadiagnostictestevaluation
AT mathewbenila comparisonofdiagnosticabilityofconventionalfilmandstoragephosphorplateindetectingproximalcarieswithdirectmeasurementsbystereomicroscopeadiagnostictestevaluation
AT vidyadharanmathew comparisonofdiagnosticabilityofconventionalfilmandstoragephosphorplateindetectingproximalcarieswithdirectmeasurementsbystereomicroscopeadiagnostictestevaluation
AT nairaparnam comparisonofdiagnosticabilityofconventionalfilmandstoragephosphorplateindetectingproximalcarieswithdirectmeasurementsbystereomicroscopeadiagnostictestevaluation