Cargando…

Characterization of microchannel plate detector response for the detection of native multiply charged high mass single ions in orthogonal‐time‐of‐flight mass spectrometry using a Timepix detector

Time‐of‐flight (TOF) systems are one of the most widely used mass analyzers in native mass spectrometry (nMS) for the analysis of non‐covalent multiply charged bio‐macromolecular assemblies (MMAs). Typically, microchannel plates (MCPs) are employed for high mass native ion detection in TOF MS. MCPs...

Descripción completa

Detalles Bibliográficos
Autores principales: Mathew, Anjusha, Eijkel, Gert B., Anthony, Ian G. M., Ellis, Shane R., Heeren, Ron M. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9287041/
https://www.ncbi.nlm.nih.gov/pubmed/35347816
http://dx.doi.org/10.1002/jms.4820
_version_ 1784748161032519680
author Mathew, Anjusha
Eijkel, Gert B.
Anthony, Ian G. M.
Ellis, Shane R.
Heeren, Ron M. A.
author_facet Mathew, Anjusha
Eijkel, Gert B.
Anthony, Ian G. M.
Ellis, Shane R.
Heeren, Ron M. A.
author_sort Mathew, Anjusha
collection PubMed
description Time‐of‐flight (TOF) systems are one of the most widely used mass analyzers in native mass spectrometry (nMS) for the analysis of non‐covalent multiply charged bio‐macromolecular assemblies (MMAs). Typically, microchannel plates (MCPs) are employed for high mass native ion detection in TOF MS. MCPs are well known for their reduced detection efficiency when impinged by large slow moving ions. Here, a position‐ and time‐sensitive Timepix (TPX) detector has been added to the back of a dual MCP stack to study the key factors that affect MCP performance for MMA ions generated by nMS. The footprint size of the secondary electron cloud generated by the MCP on the TPX for each individual ion event is analyzed as a measure of MCP performance at each mass‐to‐charge (m/z) value and resulted in a Poisson distribution. This allowed us to investigate the dependency of ion mass, ion charge, ion velocity, acceleration voltage, and MCP bias voltage on MCP response in the high mass low velocity regime. The study of measurement ranges; ion mass = 195 to 802,000 Da, ion velocity = 8.4 to 67.4 km/s, and ion charge = 1+ to 72+, extended the previously examined mass range and characterized MCP performance for multiply charged species. We derived a MCP performance equation based on two independent ion properties, ion mass and charge, from these results, which enables rapid MCP tuning for single MMA ion detection.
format Online
Article
Text
id pubmed-9287041
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-92870412022-07-19 Characterization of microchannel plate detector response for the detection of native multiply charged high mass single ions in orthogonal‐time‐of‐flight mass spectrometry using a Timepix detector Mathew, Anjusha Eijkel, Gert B. Anthony, Ian G. M. Ellis, Shane R. Heeren, Ron M. A. J Mass Spectrom Featured Articles Time‐of‐flight (TOF) systems are one of the most widely used mass analyzers in native mass spectrometry (nMS) for the analysis of non‐covalent multiply charged bio‐macromolecular assemblies (MMAs). Typically, microchannel plates (MCPs) are employed for high mass native ion detection in TOF MS. MCPs are well known for their reduced detection efficiency when impinged by large slow moving ions. Here, a position‐ and time‐sensitive Timepix (TPX) detector has been added to the back of a dual MCP stack to study the key factors that affect MCP performance for MMA ions generated by nMS. The footprint size of the secondary electron cloud generated by the MCP on the TPX for each individual ion event is analyzed as a measure of MCP performance at each mass‐to‐charge (m/z) value and resulted in a Poisson distribution. This allowed us to investigate the dependency of ion mass, ion charge, ion velocity, acceleration voltage, and MCP bias voltage on MCP response in the high mass low velocity regime. The study of measurement ranges; ion mass = 195 to 802,000 Da, ion velocity = 8.4 to 67.4 km/s, and ion charge = 1+ to 72+, extended the previously examined mass range and characterized MCP performance for multiply charged species. We derived a MCP performance equation based on two independent ion properties, ion mass and charge, from these results, which enables rapid MCP tuning for single MMA ion detection. John Wiley and Sons Inc. 2022-03-28 2022-04 /pmc/articles/PMC9287041/ /pubmed/35347816 http://dx.doi.org/10.1002/jms.4820 Text en © 2022 The Authors. Journal of Mass Spectrometry published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Featured Articles
Mathew, Anjusha
Eijkel, Gert B.
Anthony, Ian G. M.
Ellis, Shane R.
Heeren, Ron M. A.
Characterization of microchannel plate detector response for the detection of native multiply charged high mass single ions in orthogonal‐time‐of‐flight mass spectrometry using a Timepix detector
title Characterization of microchannel plate detector response for the detection of native multiply charged high mass single ions in orthogonal‐time‐of‐flight mass spectrometry using a Timepix detector
title_full Characterization of microchannel plate detector response for the detection of native multiply charged high mass single ions in orthogonal‐time‐of‐flight mass spectrometry using a Timepix detector
title_fullStr Characterization of microchannel plate detector response for the detection of native multiply charged high mass single ions in orthogonal‐time‐of‐flight mass spectrometry using a Timepix detector
title_full_unstemmed Characterization of microchannel plate detector response for the detection of native multiply charged high mass single ions in orthogonal‐time‐of‐flight mass spectrometry using a Timepix detector
title_short Characterization of microchannel plate detector response for the detection of native multiply charged high mass single ions in orthogonal‐time‐of‐flight mass spectrometry using a Timepix detector
title_sort characterization of microchannel plate detector response for the detection of native multiply charged high mass single ions in orthogonal‐time‐of‐flight mass spectrometry using a timepix detector
topic Featured Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9287041/
https://www.ncbi.nlm.nih.gov/pubmed/35347816
http://dx.doi.org/10.1002/jms.4820
work_keys_str_mv AT mathewanjusha characterizationofmicrochannelplatedetectorresponseforthedetectionofnativemultiplychargedhighmasssingleionsinorthogonaltimeofflightmassspectrometryusingatimepixdetector
AT eijkelgertb characterizationofmicrochannelplatedetectorresponseforthedetectionofnativemultiplychargedhighmasssingleionsinorthogonaltimeofflightmassspectrometryusingatimepixdetector
AT anthonyiangm characterizationofmicrochannelplatedetectorresponseforthedetectionofnativemultiplychargedhighmasssingleionsinorthogonaltimeofflightmassspectrometryusingatimepixdetector
AT ellisshaner characterizationofmicrochannelplatedetectorresponseforthedetectionofnativemultiplychargedhighmasssingleionsinorthogonaltimeofflightmassspectrometryusingatimepixdetector
AT heerenronma characterizationofmicrochannelplatedetectorresponseforthedetectionofnativemultiplychargedhighmasssingleionsinorthogonaltimeofflightmassspectrometryusingatimepixdetector