Cargando…

Development and validation of a high resolving power absolute quantitative per‐ and polyfluoroalkyl substances method incorporating Skyline data processing

RATIONALE: The ability to perform absolute quantitation and non‐targeted analysis on a single mass spectrometry instrument would be advantageous to many researchers studying per‐ and polyfluoroalkyl substances (PFAS). High‐resolution accurate mass (HRAM) instrumentation (typically deployed for non‐t...

Descripción completa

Detalles Bibliográficos
Autores principales: Enders, Jeffrey R., Weed, Rebecca A., Griffith, Emily H., Muddiman, David C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9287086/
https://www.ncbi.nlm.nih.gov/pubmed/35275435
http://dx.doi.org/10.1002/rcm.9295
_version_ 1784748172924420096
author Enders, Jeffrey R.
Weed, Rebecca A.
Griffith, Emily H.
Muddiman, David C.
author_facet Enders, Jeffrey R.
Weed, Rebecca A.
Griffith, Emily H.
Muddiman, David C.
author_sort Enders, Jeffrey R.
collection PubMed
description RATIONALE: The ability to perform absolute quantitation and non‐targeted analysis on a single mass spectrometry instrument would be advantageous to many researchers studying per‐ and polyfluoroalkyl substances (PFAS). High‐resolution accurate mass (HRAM) instrumentation (typically deployed for non‐targeted work) carries several advantages over traditional triple quadrupole workflows when performing absolute quantitation. Processing this data using a vendor‐neutral software would promote collaboration for these environmental studies. METHODS: LC‐MS (Orbitrap Exploris 240) was used for absolute quantitation of 45 PFAS using precursor (MS1) peak areas for quantitation, whereas isotope pattern matching and fragmentation (MS2) pattern matching were used for qualitative identification. In addition, a fluorinated chromatographic column achieved superior separation compared to the typical C18 columns typically used in PFAS analyses. This method was validated across eight different chemical classes using recommended guidelines found in EPA Method 537.1 and Skyline data processing software. RESULTS: The validated limits of all 45 compounds, as well as metrics or accuracy and reproducibility, are reported. Most compounds achieved limits of quantitation in the range of 2‐50 ng/L. Four newly released Chemours‐specific compounds (PEPA, PFO3OA, PFO4DA, and PFO5DoA) were also validated. Aspects of data analysis specific to high resolving power absolute quantitation are reviewed as are the details of processing these data via Skyline. CONCLUSIONS: This method shows the feasibility of performing reproducible absolute quantitation of PFAS on an HRAM platform and does so using an open‐source vendor‐neutral data processing software to facilitate sharing of data across labs and institutions.
format Online
Article
Text
id pubmed-9287086
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-92870862022-07-19 Development and validation of a high resolving power absolute quantitative per‐ and polyfluoroalkyl substances method incorporating Skyline data processing Enders, Jeffrey R. Weed, Rebecca A. Griffith, Emily H. Muddiman, David C. Rapid Commun Mass Spectrom Research Articles RATIONALE: The ability to perform absolute quantitation and non‐targeted analysis on a single mass spectrometry instrument would be advantageous to many researchers studying per‐ and polyfluoroalkyl substances (PFAS). High‐resolution accurate mass (HRAM) instrumentation (typically deployed for non‐targeted work) carries several advantages over traditional triple quadrupole workflows when performing absolute quantitation. Processing this data using a vendor‐neutral software would promote collaboration for these environmental studies. METHODS: LC‐MS (Orbitrap Exploris 240) was used for absolute quantitation of 45 PFAS using precursor (MS1) peak areas for quantitation, whereas isotope pattern matching and fragmentation (MS2) pattern matching were used for qualitative identification. In addition, a fluorinated chromatographic column achieved superior separation compared to the typical C18 columns typically used in PFAS analyses. This method was validated across eight different chemical classes using recommended guidelines found in EPA Method 537.1 and Skyline data processing software. RESULTS: The validated limits of all 45 compounds, as well as metrics or accuracy and reproducibility, are reported. Most compounds achieved limits of quantitation in the range of 2‐50 ng/L. Four newly released Chemours‐specific compounds (PEPA, PFO3OA, PFO4DA, and PFO5DoA) were also validated. Aspects of data analysis specific to high resolving power absolute quantitation are reviewed as are the details of processing these data via Skyline. CONCLUSIONS: This method shows the feasibility of performing reproducible absolute quantitation of PFAS on an HRAM platform and does so using an open‐source vendor‐neutral data processing software to facilitate sharing of data across labs and institutions. John Wiley and Sons Inc. 2022-03-25 2022-06-15 /pmc/articles/PMC9287086/ /pubmed/35275435 http://dx.doi.org/10.1002/rcm.9295 Text en © 2022 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Enders, Jeffrey R.
Weed, Rebecca A.
Griffith, Emily H.
Muddiman, David C.
Development and validation of a high resolving power absolute quantitative per‐ and polyfluoroalkyl substances method incorporating Skyline data processing
title Development and validation of a high resolving power absolute quantitative per‐ and polyfluoroalkyl substances method incorporating Skyline data processing
title_full Development and validation of a high resolving power absolute quantitative per‐ and polyfluoroalkyl substances method incorporating Skyline data processing
title_fullStr Development and validation of a high resolving power absolute quantitative per‐ and polyfluoroalkyl substances method incorporating Skyline data processing
title_full_unstemmed Development and validation of a high resolving power absolute quantitative per‐ and polyfluoroalkyl substances method incorporating Skyline data processing
title_short Development and validation of a high resolving power absolute quantitative per‐ and polyfluoroalkyl substances method incorporating Skyline data processing
title_sort development and validation of a high resolving power absolute quantitative per‐ and polyfluoroalkyl substances method incorporating skyline data processing
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9287086/
https://www.ncbi.nlm.nih.gov/pubmed/35275435
http://dx.doi.org/10.1002/rcm.9295
work_keys_str_mv AT endersjeffreyr developmentandvalidationofahighresolvingpowerabsolutequantitativeperandpolyfluoroalkylsubstancesmethodincorporatingskylinedataprocessing
AT weedrebeccaa developmentandvalidationofahighresolvingpowerabsolutequantitativeperandpolyfluoroalkylsubstancesmethodincorporatingskylinedataprocessing
AT griffithemilyh developmentandvalidationofahighresolvingpowerabsolutequantitativeperandpolyfluoroalkylsubstancesmethodincorporatingskylinedataprocessing
AT muddimandavidc developmentandvalidationofahighresolvingpowerabsolutequantitativeperandpolyfluoroalkylsubstancesmethodincorporatingskylinedataprocessing