Cargando…

A prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study

BACKGROUND: To establish and verify the accuracy and reliability of a sulcus-to-sulcus diameter (STS) prediction model. METHODS: In this retrospective study, the prediction formula was established with the data from 1466 eyes from 733 subjects from July 2020 to April 2021 and verified with the data...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Qiu-Jian, Zhu, Wei-Jian, Chen, Wen-Jing, Ma, Lie, Yuan, You
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9287952/
https://www.ncbi.nlm.nih.gov/pubmed/35842598
http://dx.doi.org/10.1186/s12886-022-02535-3
_version_ 1784748359794294784
author Zhu, Qiu-Jian
Zhu, Wei-Jian
Chen, Wen-Jing
Ma, Lie
Yuan, You
author_facet Zhu, Qiu-Jian
Zhu, Wei-Jian
Chen, Wen-Jing
Ma, Lie
Yuan, You
author_sort Zhu, Qiu-Jian
collection PubMed
description BACKGROUND: To establish and verify the accuracy and reliability of a sulcus-to-sulcus diameter (STS) prediction model. METHODS: In this retrospective study, the prediction formula was established with the data from 1466 eyes from 733 subjects from July 2020 to April 2021 and verified with the data from 278 eyes from 139 subjects between May 2021 and June 2021. Each subject was measured with a Pentacam, IOLMaster 700, OPD-Scan III, and ultrasound biomicroscope. The prediction formulas were established with multiple linear regression, and intergroup correlation coefficients (ICCs) and Bland–Altman tests were used to assess the agreement between the predicted and actual STS (actual STS was measured by UBM). RESULTS: The explanatory variables relevant to the horizontal STS (STSH) were the Pentacam white-to-white diameter (WTWP; standardized partial regression coefficient [β] = 0.330; p < 0.001), the flat K value (β = -0.211; p < 0.001), and the anterior corneal diameter (ACD) (β = 0.178; p < 0.001). The corresponding multiple regression equation was : STSH (mm) = 8.061 + 0.510 × WTWP − 0.090 × Flat K value + 0.430 × ACD. The explanatory variables relevant to the vertical STS (STSV) were the WTWP (β = 0.435; p < 0.001), the steep K value (β = -0.271; p < 0.001), and the ACD (β = 0.187; p < 0.001). The corresponding multiple regression equation was : STSV (mm) = 8.540 + 0.492 × WTWP − 0.075 × Steep K value + 0.329 × ACD. The bias of the predicted to the actual STSH was − 0.021, with 95% limits of agreement (95% LoA) from − 0.499 to 0.457. The bias of the predicted to the actual STSV was 0.057, with 95% LoA from − 0.462 to 0.575. The ICC was 0.883 between the predicted and actual STSH and 0.859 between the predicted and actual STSV. CONCLUSIONS: The Pentacam-measured WTW, the K value and the ACD are important for predicting the STS diameter. The prediction model has good accuracy and reliability. TRIAL REGISTRATION: Not applicable.
format Online
Article
Text
id pubmed-9287952
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-92879522022-07-17 A prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study Zhu, Qiu-Jian Zhu, Wei-Jian Chen, Wen-Jing Ma, Lie Yuan, You BMC Ophthalmol Research BACKGROUND: To establish and verify the accuracy and reliability of a sulcus-to-sulcus diameter (STS) prediction model. METHODS: In this retrospective study, the prediction formula was established with the data from 1466 eyes from 733 subjects from July 2020 to April 2021 and verified with the data from 278 eyes from 139 subjects between May 2021 and June 2021. Each subject was measured with a Pentacam, IOLMaster 700, OPD-Scan III, and ultrasound biomicroscope. The prediction formulas were established with multiple linear regression, and intergroup correlation coefficients (ICCs) and Bland–Altman tests were used to assess the agreement between the predicted and actual STS (actual STS was measured by UBM). RESULTS: The explanatory variables relevant to the horizontal STS (STSH) were the Pentacam white-to-white diameter (WTWP; standardized partial regression coefficient [β] = 0.330; p < 0.001), the flat K value (β = -0.211; p < 0.001), and the anterior corneal diameter (ACD) (β = 0.178; p < 0.001). The corresponding multiple regression equation was : STSH (mm) = 8.061 + 0.510 × WTWP − 0.090 × Flat K value + 0.430 × ACD. The explanatory variables relevant to the vertical STS (STSV) were the WTWP (β = 0.435; p < 0.001), the steep K value (β = -0.271; p < 0.001), and the ACD (β = 0.187; p < 0.001). The corresponding multiple regression equation was : STSV (mm) = 8.540 + 0.492 × WTWP − 0.075 × Steep K value + 0.329 × ACD. The bias of the predicted to the actual STSH was − 0.021, with 95% limits of agreement (95% LoA) from − 0.499 to 0.457. The bias of the predicted to the actual STSV was 0.057, with 95% LoA from − 0.462 to 0.575. The ICC was 0.883 between the predicted and actual STSH and 0.859 between the predicted and actual STSV. CONCLUSIONS: The Pentacam-measured WTW, the K value and the ACD are important for predicting the STS diameter. The prediction model has good accuracy and reliability. TRIAL REGISTRATION: Not applicable. BioMed Central 2022-07-16 /pmc/articles/PMC9287952/ /pubmed/35842598 http://dx.doi.org/10.1186/s12886-022-02535-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Zhu, Qiu-Jian
Zhu, Wei-Jian
Chen, Wen-Jing
Ma, Lie
Yuan, You
A prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study
title A prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study
title_full A prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study
title_fullStr A prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study
title_full_unstemmed A prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study
title_short A prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study
title_sort prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9287952/
https://www.ncbi.nlm.nih.gov/pubmed/35842598
http://dx.doi.org/10.1186/s12886-022-02535-3
work_keys_str_mv AT zhuqiujian apredictionmodelforsulcustosulcusdiameterinmyopiceyesa1466sampleretrospectivestudy
AT zhuweijian apredictionmodelforsulcustosulcusdiameterinmyopiceyesa1466sampleretrospectivestudy
AT chenwenjing apredictionmodelforsulcustosulcusdiameterinmyopiceyesa1466sampleretrospectivestudy
AT malie apredictionmodelforsulcustosulcusdiameterinmyopiceyesa1466sampleretrospectivestudy
AT yuanyou apredictionmodelforsulcustosulcusdiameterinmyopiceyesa1466sampleretrospectivestudy
AT zhuqiujian predictionmodelforsulcustosulcusdiameterinmyopiceyesa1466sampleretrospectivestudy
AT zhuweijian predictionmodelforsulcustosulcusdiameterinmyopiceyesa1466sampleretrospectivestudy
AT chenwenjing predictionmodelforsulcustosulcusdiameterinmyopiceyesa1466sampleretrospectivestudy
AT malie predictionmodelforsulcustosulcusdiameterinmyopiceyesa1466sampleretrospectivestudy
AT yuanyou predictionmodelforsulcustosulcusdiameterinmyopiceyesa1466sampleretrospectivestudy