Cargando…
Elastic Stable Intramedullary Fixation Using Epibloc versus Crossed Kirschner Wires Fixation for Distal Forearm Fractures in Children: A Retrospective Analysis
BACKGROUND: Childrens' distal forearm fractures (DFFs) could be treated conservatively with closed reduction and immobilisation, but post-reduction displacements often occur. Displaced DFF should be surgically fixed, to avoid further displacement. Nevertheless, immobilisation after surgery is r...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9290372/ https://www.ncbi.nlm.nih.gov/pubmed/35775516 http://dx.doi.org/10.4103/ajps.AJPS_178_20 |
Sumario: | BACKGROUND: Childrens' distal forearm fractures (DFFs) could be treated conservatively with closed reduction and immobilisation, but post-reduction displacements often occur. Displaced DFF should be surgically fixed, to avoid further displacement. Nevertheless, immobilisation after surgery is recommended. Epibloc system (ES), a system of stable elastic nail fixation, is widely used to stabilise adults extra-articular distal radius fractures, with advantages to not requiring post-surgical immobilisation. The present investigation represents a retrospective analysis of paediatric patients with DFF treated with ES applied with a minimal technical variation, to fix both ulna and radius fractures using a unique device. MATERIALS AND METHODS: A retrospective analysis was performed on 44 children (age 6–11 years) who underwent closed reduction and internal fixation because of DFF (both ulna and radius). Group A (21 patients): ES fixation. Group B (23 patients): K-wires and short arm cast fixation. The primary outcome was the subsistence of reduction monitored through X-rays. The secondary outcome was the measurement of active range of motion (AROM) and the time of recovery. RESULTS: No differences were observed comparing Group A and B in terms of the maintenance of reduction (P > 0.05). Seven days after the implant removal, patients in Group A reached significantly better results compared to patients in Group B in terms of AROM (P < 0.05). No differences were revealed in terms of complications between the two groups. CONCLUSION: ES applied with a minimal technical variation is safe and effective in treating distal ulna and radius fractures, with minimal requirement of post-surgical rehabilitation. |
---|