Characterization and comparison of a 2-, 4- and 8-MHz central venous catheter ultrasound probe for venous air emboli detection
This paper presents a concept for detection of venous air emboli inside the superior vena cava using a central venous catheter with integrated Doppler ultrasound transducer installed on the tip. Several Doppler probes each with a single insonation frequencies of 2 MHz, 4 MHz or 8 MHz are characteriz...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
German Medical Science GMS Publishing House
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9290754/ https://www.ncbi.nlm.nih.gov/pubmed/35910412 http://dx.doi.org/10.3205/hta000135 |
_version_ | 1784748983441162240 |
---|---|
author | Stark, Philipp Ch. Kalkbrenner, Christoph Klingler, Werner Brucher, Rainer |
author_facet | Stark, Philipp Ch. Kalkbrenner, Christoph Klingler, Werner Brucher, Rainer |
author_sort | Stark, Philipp Ch. |
collection | PubMed |
description | This paper presents a concept for detection of venous air emboli inside the superior vena cava using a central venous catheter with integrated Doppler ultrasound transducer installed on the tip. Several Doppler probes each with a single insonation frequencies of 2 MHz, 4 MHz or 8 MHz are characterized and compared for usefulness in this scenario. During in vitro experiments using an artificial blood circulatory with blood mimicking fluid bubbles with defined volumes were injected and recorded as gaseous embolic events. The in vitro results of measured embolus-blood-ratio values (EBR) in respect to the air bubbles volumes and its echogenicity showed a good correlation with the simulation model of spherical cross section scattering of such air bubbles. It is shown that the probe design still needs some improvements using a 4 MHz insonation frequency to get a useable detection sensitivity in such scenario within vena cava superior. The results suggest that it is possible to estimate the air bubble volume corresponding to the EBR using such a catheter probe. |
format | Online Article Text |
id | pubmed-9290754 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | German Medical Science GMS Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-92907542022-07-29 Characterization and comparison of a 2-, 4- and 8-MHz central venous catheter ultrasound probe for venous air emboli detection Stark, Philipp Ch. Kalkbrenner, Christoph Klingler, Werner Brucher, Rainer GMS Health Innov Technol Article This paper presents a concept for detection of venous air emboli inside the superior vena cava using a central venous catheter with integrated Doppler ultrasound transducer installed on the tip. Several Doppler probes each with a single insonation frequencies of 2 MHz, 4 MHz or 8 MHz are characterized and compared for usefulness in this scenario. During in vitro experiments using an artificial blood circulatory with blood mimicking fluid bubbles with defined volumes were injected and recorded as gaseous embolic events. The in vitro results of measured embolus-blood-ratio values (EBR) in respect to the air bubbles volumes and its echogenicity showed a good correlation with the simulation model of spherical cross section scattering of such air bubbles. It is shown that the probe design still needs some improvements using a 4 MHz insonation frequency to get a useable detection sensitivity in such scenario within vena cava superior. The results suggest that it is possible to estimate the air bubble volume corresponding to the EBR using such a catheter probe. German Medical Science GMS Publishing House 2022-06-22 /pmc/articles/PMC9290754/ /pubmed/35910412 http://dx.doi.org/10.3205/hta000135 Text en Copyright © 2022 Stark et al. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License. See license information at http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Stark, Philipp Ch. Kalkbrenner, Christoph Klingler, Werner Brucher, Rainer Characterization and comparison of a 2-, 4- and 8-MHz central venous catheter ultrasound probe for venous air emboli detection |
title | Characterization and comparison of a 2-, 4- and 8-MHz central venous catheter ultrasound probe for venous air emboli detection |
title_full | Characterization and comparison of a 2-, 4- and 8-MHz central venous catheter ultrasound probe for venous air emboli detection |
title_fullStr | Characterization and comparison of a 2-, 4- and 8-MHz central venous catheter ultrasound probe for venous air emboli detection |
title_full_unstemmed | Characterization and comparison of a 2-, 4- and 8-MHz central venous catheter ultrasound probe for venous air emboli detection |
title_short | Characterization and comparison of a 2-, 4- and 8-MHz central venous catheter ultrasound probe for venous air emboli detection |
title_sort | characterization and comparison of a 2-, 4- and 8-mhz central venous catheter ultrasound probe for venous air emboli detection |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9290754/ https://www.ncbi.nlm.nih.gov/pubmed/35910412 http://dx.doi.org/10.3205/hta000135 |
work_keys_str_mv | AT starkphilippch characterizationandcomparisonofa24and8mhzcentralvenouscatheterultrasoundprobeforvenousairembolidetection AT kalkbrennerchristoph characterizationandcomparisonofa24and8mhzcentralvenouscatheterultrasoundprobeforvenousairembolidetection AT klinglerwerner characterizationandcomparisonofa24and8mhzcentralvenouscatheterultrasoundprobeforvenousairembolidetection AT brucherrainer characterizationandcomparisonofa24and8mhzcentralvenouscatheterultrasoundprobeforvenousairembolidetection |