Cargando…

MRI‐based synthetic CT shows equivalence to conventional CT for the morphological assessment of the hip joint

This study evaluated the accuracy of synthetic computed tomography (sCT), as compared to CT, for the 3D assessment of the hip morphology. Thirty male patients with asymptomatic hips, referred for magnetic resonance (MR) imaging and CT, were included in this retrospective study. sCT images were gener...

Descripción completa

Detalles Bibliográficos
Autores principales: Florkow, Mateusz C., Willemsen, Koen, Zijlstra, Frank, Foppen, Wouter, van der Wal, Bart C. H., van der Voort van Zyp, Jochem R. N., Viergever, Max A., Castelein, René M., Weinans, Harrie, van Stralen, Marijn, Sakkers, Ralph J. B., Seevinck, Peter R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9291600/
https://www.ncbi.nlm.nih.gov/pubmed/34191351
http://dx.doi.org/10.1002/jor.25127
_version_ 1784749173784969216
author Florkow, Mateusz C.
Willemsen, Koen
Zijlstra, Frank
Foppen, Wouter
van der Wal, Bart C. H.
van der Voort van Zyp, Jochem R. N.
Viergever, Max A.
Castelein, René M.
Weinans, Harrie
van Stralen, Marijn
Sakkers, Ralph J. B.
Seevinck, Peter R.
author_facet Florkow, Mateusz C.
Willemsen, Koen
Zijlstra, Frank
Foppen, Wouter
van der Wal, Bart C. H.
van der Voort van Zyp, Jochem R. N.
Viergever, Max A.
Castelein, René M.
Weinans, Harrie
van Stralen, Marijn
Sakkers, Ralph J. B.
Seevinck, Peter R.
author_sort Florkow, Mateusz C.
collection PubMed
description This study evaluated the accuracy of synthetic computed tomography (sCT), as compared to CT, for the 3D assessment of the hip morphology. Thirty male patients with asymptomatic hips, referred for magnetic resonance (MR) imaging and CT, were included in this retrospective study. sCT images were generated from three‐dimensional radiofrequency‐spoiled T1‐weighted multi‐echo gradient‐echo MR images using a commercially available deep learning‐enabled software and were compared with CT images through mean error and surface distance computation and by means of eight clinical morphometric parameters relevant for hip care. Parameters included center‐edge angle (CEA), sharp angle, acetabular index, extrusion index, femoral head center‐to‐midline distance, acetabular version (AV), and anterior and posterior acetabular sector angles. They were measured by two senior orthopedic surgeons and a radiologist in‐training on CT and sCT images. The reliability and agreement of CT‐ and sCT‐based measurements were assessed using intraclass correlation coefficients (ICCs) for absolute agreement, Bland–Altman plots, and two one‐sided tests for equivalence. The surface distance between CT‐ and sCT‐based bone models were on average submillimeter. CT‐ and sCT‐based measurements showed moderate to excellent interobserver and intraobserver correlation (0.56 < ICC < 0.99). In particular, the inter/intraobserver agreements were good for AV (ICC > 0.75). For CEA, the intraobserver agreement was good (ICC > 0.75) and the interobserver agreement was moderate (ICC > 0.69). Limits of agreements were similar between intraobserver CT and intermodal measurements. All measurements were found statistically equivalent, with average intermodal differences within the intraobserver limits of agreement. In conclusion, sCT and CT were equivalent for the assessment of the hip joint bone morphology.
format Online
Article
Text
id pubmed-9291600
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-92916002022-07-20 MRI‐based synthetic CT shows equivalence to conventional CT for the morphological assessment of the hip joint Florkow, Mateusz C. Willemsen, Koen Zijlstra, Frank Foppen, Wouter van der Wal, Bart C. H. van der Voort van Zyp, Jochem R. N. Viergever, Max A. Castelein, René M. Weinans, Harrie van Stralen, Marijn Sakkers, Ralph J. B. Seevinck, Peter R. J Orthop Res Research Articles This study evaluated the accuracy of synthetic computed tomography (sCT), as compared to CT, for the 3D assessment of the hip morphology. Thirty male patients with asymptomatic hips, referred for magnetic resonance (MR) imaging and CT, were included in this retrospective study. sCT images were generated from three‐dimensional radiofrequency‐spoiled T1‐weighted multi‐echo gradient‐echo MR images using a commercially available deep learning‐enabled software and were compared with CT images through mean error and surface distance computation and by means of eight clinical morphometric parameters relevant for hip care. Parameters included center‐edge angle (CEA), sharp angle, acetabular index, extrusion index, femoral head center‐to‐midline distance, acetabular version (AV), and anterior and posterior acetabular sector angles. They were measured by two senior orthopedic surgeons and a radiologist in‐training on CT and sCT images. The reliability and agreement of CT‐ and sCT‐based measurements were assessed using intraclass correlation coefficients (ICCs) for absolute agreement, Bland–Altman plots, and two one‐sided tests for equivalence. The surface distance between CT‐ and sCT‐based bone models were on average submillimeter. CT‐ and sCT‐based measurements showed moderate to excellent interobserver and intraobserver correlation (0.56 < ICC < 0.99). In particular, the inter/intraobserver agreements were good for AV (ICC > 0.75). For CEA, the intraobserver agreement was good (ICC > 0.75) and the interobserver agreement was moderate (ICC > 0.69). Limits of agreements were similar between intraobserver CT and intermodal measurements. All measurements were found statistically equivalent, with average intermodal differences within the intraobserver limits of agreement. In conclusion, sCT and CT were equivalent for the assessment of the hip joint bone morphology. John Wiley and Sons Inc. 2021-07-12 2022-04 /pmc/articles/PMC9291600/ /pubmed/34191351 http://dx.doi.org/10.1002/jor.25127 Text en © 2021 The Authors. Journal of Orthopaedic Research® published by Wiley Periodicals LLC on behalf of Orthopaedic Research Society. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Florkow, Mateusz C.
Willemsen, Koen
Zijlstra, Frank
Foppen, Wouter
van der Wal, Bart C. H.
van der Voort van Zyp, Jochem R. N.
Viergever, Max A.
Castelein, René M.
Weinans, Harrie
van Stralen, Marijn
Sakkers, Ralph J. B.
Seevinck, Peter R.
MRI‐based synthetic CT shows equivalence to conventional CT for the morphological assessment of the hip joint
title MRI‐based synthetic CT shows equivalence to conventional CT for the morphological assessment of the hip joint
title_full MRI‐based synthetic CT shows equivalence to conventional CT for the morphological assessment of the hip joint
title_fullStr MRI‐based synthetic CT shows equivalence to conventional CT for the morphological assessment of the hip joint
title_full_unstemmed MRI‐based synthetic CT shows equivalence to conventional CT for the morphological assessment of the hip joint
title_short MRI‐based synthetic CT shows equivalence to conventional CT for the morphological assessment of the hip joint
title_sort mri‐based synthetic ct shows equivalence to conventional ct for the morphological assessment of the hip joint
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9291600/
https://www.ncbi.nlm.nih.gov/pubmed/34191351
http://dx.doi.org/10.1002/jor.25127
work_keys_str_mv AT florkowmateuszc mribasedsyntheticctshowsequivalencetoconventionalctforthemorphologicalassessmentofthehipjoint
AT willemsenkoen mribasedsyntheticctshowsequivalencetoconventionalctforthemorphologicalassessmentofthehipjoint
AT zijlstrafrank mribasedsyntheticctshowsequivalencetoconventionalctforthemorphologicalassessmentofthehipjoint
AT foppenwouter mribasedsyntheticctshowsequivalencetoconventionalctforthemorphologicalassessmentofthehipjoint
AT vanderwalbartch mribasedsyntheticctshowsequivalencetoconventionalctforthemorphologicalassessmentofthehipjoint
AT vandervoortvanzypjochemrn mribasedsyntheticctshowsequivalencetoconventionalctforthemorphologicalassessmentofthehipjoint
AT viergevermaxa mribasedsyntheticctshowsequivalencetoconventionalctforthemorphologicalassessmentofthehipjoint
AT casteleinrenem mribasedsyntheticctshowsequivalencetoconventionalctforthemorphologicalassessmentofthehipjoint
AT weinansharrie mribasedsyntheticctshowsequivalencetoconventionalctforthemorphologicalassessmentofthehipjoint
AT vanstralenmarijn mribasedsyntheticctshowsequivalencetoconventionalctforthemorphologicalassessmentofthehipjoint
AT sakkersralphjb mribasedsyntheticctshowsequivalencetoconventionalctforthemorphologicalassessmentofthehipjoint
AT seevinckpeterr mribasedsyntheticctshowsequivalencetoconventionalctforthemorphologicalassessmentofthehipjoint