Quantification of internal dosimetry in PET patients II: Individualized Monte Carlo‐based dosimetry for [18F]fluorocholine PET
PURPOSE: To obtain individualized internal doses with a Monte Carlo (MC) method in patients undergoing diagnostic [18F]FCH‐PET studies and to compare such doses with the MIRD method calculations. METHODS: A patient cohort of 17 males were imaged after intravenous administration of a mean [18F]FCH ac...
Autores principales: | Neira, Sara, Guiu‐Souto, Jacobo, Pais, Paulino, Rodríguez Martínez de Llano, Sofía, Fernández, Carlos, Pubul, Virginia, Ruibal, Álvaro, Pombar, Miguel, Gago‐Arias, Araceli, Pardo‐Montero, Juan |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9291792/ https://www.ncbi.nlm.nih.gov/pubmed/34260065 http://dx.doi.org/10.1002/mp.15090 |
Ejemplares similares
-
Quantification of internal dosimetry in PET patients: individualized Monte Carlo vs generic phantom‐based calculations
por: Neira, Sara, et al.
Publicado: (2020) -
PET-Based Human Dosimetry of (68)Ga-NODAGA-Exendin-4, a Tracer for β-Cell Imaging
por: Boss, Marti, et al.
Publicado: (2020) -
Internal breast dosimetry in mammography: Monte Carlo validation in homogeneous and anthropomorphic breast phantoms with a clinical mammography system
por: Fedon, Christian, et al.
Publicado: (2018) -
Experimental validation of Monte Carlo dosimetry for therapeutic beta emitters with radiochromic film in a 3D‐printed phantom
por: Van, Benjamin, et al.
Publicado: (2022) -
Validation of Monte Carlo (131)I radiopharmaceutical dosimetry workflow using a 3D‐printed anthropomorphic head and neck phantom
por: Adam, David P., et al.
Publicado: (2022)