Cargando…

A Novel Telescopic Access Sheath Method to Manage Encrusted or Knotted Retained Ureteral Stents

PURPOSE: Encrusted and knotted stents may cause serious urologic complications. This study aimed to develop a novel and minimally invasive technique to manage encrusted or knotted retained ureteral stents. MATERIALS AND METHODS: This technique was used in nine patients with retained stents. Through...

Descripción completa

Detalles Bibliográficos
Autor principal: Agarwal, Dinesh K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mary Ann Liebert, Inc., publishers 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9293677/
https://www.ncbi.nlm.nih.gov/pubmed/35156842
http://dx.doi.org/10.1089/end.2021.0942
_version_ 1784749689599426560
author Agarwal, Dinesh K.
author_facet Agarwal, Dinesh K.
author_sort Agarwal, Dinesh K.
collection PubMed
description PURPOSE: Encrusted and knotted stents may cause serious urologic complications. This study aimed to develop a novel and minimally invasive technique to manage encrusted or knotted retained ureteral stents. MATERIALS AND METHODS: This technique was used in nine patients with retained stents. Through rigid cystoscopy, the stents were pulled out of the urinary meatus. The access sheath was modified by cutting the distal end of its obturator. The modified access sheath was advanced over the retained stents in a telescopic manner to remove the encrusted and/or knotted stents. RESULTS: Six patients had encrustations, two had knot formation, and one had both encrustation and knot formation. The encrustations were peeled off in the process. The knots were either undone or pulled through the lumen of the access sheath. The retained stents were removed intact from all patients without any complications. CONCLUSION: The access sheath method described in this article provides a simple alternative for the removal of encrusted or knotted retained stents. However, this technique requires further validation to establish its safety and efficacy.
format Online
Article
Text
id pubmed-9293677
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Mary Ann Liebert, Inc., publishers
record_format MEDLINE/PubMed
spelling pubmed-92936772022-08-01 A Novel Telescopic Access Sheath Method to Manage Encrusted or Knotted Retained Ureteral Stents Agarwal, Dinesh K. J Endourol Experimental Endourology PURPOSE: Encrusted and knotted stents may cause serious urologic complications. This study aimed to develop a novel and minimally invasive technique to manage encrusted or knotted retained ureteral stents. MATERIALS AND METHODS: This technique was used in nine patients with retained stents. Through rigid cystoscopy, the stents were pulled out of the urinary meatus. The access sheath was modified by cutting the distal end of its obturator. The modified access sheath was advanced over the retained stents in a telescopic manner to remove the encrusted and/or knotted stents. RESULTS: Six patients had encrustations, two had knot formation, and one had both encrustation and knot formation. The encrustations were peeled off in the process. The knots were either undone or pulled through the lumen of the access sheath. The retained stents were removed intact from all patients without any complications. CONCLUSION: The access sheath method described in this article provides a simple alternative for the removal of encrusted or knotted retained stents. However, this technique requires further validation to establish its safety and efficacy. Mary Ann Liebert, Inc., publishers 2022-07-01 2022-07-05 /pmc/articles/PMC9293677/ /pubmed/35156842 http://dx.doi.org/10.1089/end.2021.0942 Text en © Dinesh K. Agarwal, 2022; Published by Mary Ann Liebert, Inc. https://creativecommons.org/licenses/by/4.0/This Open Access article is distributed under the terms of the Creative Commons License (http://creativecommons.org/licenses/by/4.0 (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited.
spellingShingle Experimental Endourology
Agarwal, Dinesh K.
A Novel Telescopic Access Sheath Method to Manage Encrusted or Knotted Retained Ureteral Stents
title A Novel Telescopic Access Sheath Method to Manage Encrusted or Knotted Retained Ureteral Stents
title_full A Novel Telescopic Access Sheath Method to Manage Encrusted or Knotted Retained Ureteral Stents
title_fullStr A Novel Telescopic Access Sheath Method to Manage Encrusted or Knotted Retained Ureteral Stents
title_full_unstemmed A Novel Telescopic Access Sheath Method to Manage Encrusted or Knotted Retained Ureteral Stents
title_short A Novel Telescopic Access Sheath Method to Manage Encrusted or Knotted Retained Ureteral Stents
title_sort novel telescopic access sheath method to manage encrusted or knotted retained ureteral stents
topic Experimental Endourology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9293677/
https://www.ncbi.nlm.nih.gov/pubmed/35156842
http://dx.doi.org/10.1089/end.2021.0942
work_keys_str_mv AT agarwaldineshk anoveltelescopicaccesssheathmethodtomanageencrustedorknottedretainedureteralstents
AT agarwaldineshk noveltelescopicaccesssheathmethodtomanageencrustedorknottedretainedureteralstents