Cargando…

Clinical Performance of Three Commercial SARS‐CoV‐2 Rapid Antigen Tests for Community-Dwelling Individuals in a Tropical Setting

During the second year of the COVID-19 pandemic, the use of Rapid Diagnosis Antigen Tests (RDAgTs) for SARS-CoV-2 detection has substantially increased as some of the brands available in the market were certified for clinical use by international regulatory agencies. RDAgTs are a fast and cheap tool...

Descripción completa

Detalles Bibliográficos
Autores principales: Morales-Jadán, Diana, Viteri-Dávila, Carolina, Castro-Rodriguez, Bernardo, Vallejo-Janeta, Alexander Paolo, Rivera-Olivero, Ismar A., Perez, Franklin, Garcia-Bereguiain, Miguel Angel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9294138/
https://www.ncbi.nlm.nih.gov/pubmed/35865818
http://dx.doi.org/10.3389/fcimb.2022.832235
_version_ 1784749782244261888
author Morales-Jadán, Diana
Viteri-Dávila, Carolina
Castro-Rodriguez, Bernardo
Vallejo-Janeta, Alexander Paolo
Rivera-Olivero, Ismar A.
Perez, Franklin
Garcia-Bereguiain, Miguel Angel
author_facet Morales-Jadán, Diana
Viteri-Dávila, Carolina
Castro-Rodriguez, Bernardo
Vallejo-Janeta, Alexander Paolo
Rivera-Olivero, Ismar A.
Perez, Franklin
Garcia-Bereguiain, Miguel Angel
author_sort Morales-Jadán, Diana
collection PubMed
description During the second year of the COVID-19 pandemic, the use of Rapid Diagnosis Antigen Tests (RDAgTs) for SARS-CoV-2 detection has substantially increased as some of the brands available in the market were certified for clinical use by international regulatory agencies. RDAgTs are a fast and cheap tool for SARS-CoV-2 surveillance with great potential to improve testing capacities in middle- and low-income countries compared to the gold standard RT-qPCR. However, as the clinical performance of RDAgTs has been shown to vary greatly between the commercial brands available, evaluation studies are necessary. Moreover, the available evaluation has been done in high-income countries while SARS-CoV-2 transmission is also actively happening in developing countries, many of which are located in tropical latitudes where cross-reactivity with other infectious agents is highly prevalent, which could compromise RDAgT specificity. Moreover, unreported mutations and/or new SARS-CoV-2 variants may compromise RDAgT sensitivity as genomic surveillance is limited in these settings. Here we describe a multicenter and manufacturer‐independent evaluation of the clinical performance and analytical sensitivity of three different RDAgTs brands available in South America from three companies, Rapigen (South Korea), SD-Biosensor (South Korea), and Certest (Spain), compared to the gold standard RT-qPCR. A total number of 1,646 nasopharyngeal swabs from community-dwelling individuals were included in the study, and 379 of them were SARS-CoV-2 positive by RT-qPCR. The overall sensitivity for each RDAgT was 79% (IC95%: 72 - 86.2), 64.2% (IC95%: 56.7 - 71.6), and 45.8% (IC95%: 35.8 - 55.8) for SD-Biosensor, Certest, and Rapigen, respectively. The overall specificity for each RDAgT was 100%, 97.7% (IC95%: 96.8 - 98.6), and 100% for SD-Biosensor, Certest, and Rapigen, respectively. However, the limit of detection (LoD) to achieve a sensitivity over 90% was substantially lower for Certest RDAgT (10(2) copies/uL) compared to SD-Biosensor (10(3) copies/uL) or Rapigen (10(6) copies/uL) RDAgTs, considering that the gold standard RT-qPCR method used in this study has a high sensitivity of 97.7% and low LoD of 5 copies/uL. Additionally, the Certest RDAgT also showed an improved sensitivity up to 79.7% (IC95%: 70.2 – 89.2) for symptomatic individuals. Finally, the slight reduction in specificity for Certest RDAgTs was only associated with one of the laboratories performing this study, pointing out the need for locally assessed evaluation for RDAgTs like this one carried out in Ecuador. In conclusion, two of the three the RDAgTs tested in this study are a fast, cheap, and point of care tool for SARS-CoV-2 surveillance and reliable enough to detect SARS-CoV-2 infectious individuals.
format Online
Article
Text
id pubmed-9294138
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-92941382022-07-20 Clinical Performance of Three Commercial SARS‐CoV‐2 Rapid Antigen Tests for Community-Dwelling Individuals in a Tropical Setting Morales-Jadán, Diana Viteri-Dávila, Carolina Castro-Rodriguez, Bernardo Vallejo-Janeta, Alexander Paolo Rivera-Olivero, Ismar A. Perez, Franklin Garcia-Bereguiain, Miguel Angel Front Cell Infect Microbiol Cellular and Infection Microbiology During the second year of the COVID-19 pandemic, the use of Rapid Diagnosis Antigen Tests (RDAgTs) for SARS-CoV-2 detection has substantially increased as some of the brands available in the market were certified for clinical use by international regulatory agencies. RDAgTs are a fast and cheap tool for SARS-CoV-2 surveillance with great potential to improve testing capacities in middle- and low-income countries compared to the gold standard RT-qPCR. However, as the clinical performance of RDAgTs has been shown to vary greatly between the commercial brands available, evaluation studies are necessary. Moreover, the available evaluation has been done in high-income countries while SARS-CoV-2 transmission is also actively happening in developing countries, many of which are located in tropical latitudes where cross-reactivity with other infectious agents is highly prevalent, which could compromise RDAgT specificity. Moreover, unreported mutations and/or new SARS-CoV-2 variants may compromise RDAgT sensitivity as genomic surveillance is limited in these settings. Here we describe a multicenter and manufacturer‐independent evaluation of the clinical performance and analytical sensitivity of three different RDAgTs brands available in South America from three companies, Rapigen (South Korea), SD-Biosensor (South Korea), and Certest (Spain), compared to the gold standard RT-qPCR. A total number of 1,646 nasopharyngeal swabs from community-dwelling individuals were included in the study, and 379 of them were SARS-CoV-2 positive by RT-qPCR. The overall sensitivity for each RDAgT was 79% (IC95%: 72 - 86.2), 64.2% (IC95%: 56.7 - 71.6), and 45.8% (IC95%: 35.8 - 55.8) for SD-Biosensor, Certest, and Rapigen, respectively. The overall specificity for each RDAgT was 100%, 97.7% (IC95%: 96.8 - 98.6), and 100% for SD-Biosensor, Certest, and Rapigen, respectively. However, the limit of detection (LoD) to achieve a sensitivity over 90% was substantially lower for Certest RDAgT (10(2) copies/uL) compared to SD-Biosensor (10(3) copies/uL) or Rapigen (10(6) copies/uL) RDAgTs, considering that the gold standard RT-qPCR method used in this study has a high sensitivity of 97.7% and low LoD of 5 copies/uL. Additionally, the Certest RDAgT also showed an improved sensitivity up to 79.7% (IC95%: 70.2 – 89.2) for symptomatic individuals. Finally, the slight reduction in specificity for Certest RDAgTs was only associated with one of the laboratories performing this study, pointing out the need for locally assessed evaluation for RDAgTs like this one carried out in Ecuador. In conclusion, two of the three the RDAgTs tested in this study are a fast, cheap, and point of care tool for SARS-CoV-2 surveillance and reliable enough to detect SARS-CoV-2 infectious individuals. Frontiers Media S.A. 2022-07-05 /pmc/articles/PMC9294138/ /pubmed/35865818 http://dx.doi.org/10.3389/fcimb.2022.832235 Text en Copyright © 2022 Morales-Jadán, Viteri-Dávila, Castro-Rodriguez, Vallejo-Janeta, Rivera-Olivero, Perez and Garcia-Bereguiain https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cellular and Infection Microbiology
Morales-Jadán, Diana
Viteri-Dávila, Carolina
Castro-Rodriguez, Bernardo
Vallejo-Janeta, Alexander Paolo
Rivera-Olivero, Ismar A.
Perez, Franklin
Garcia-Bereguiain, Miguel Angel
Clinical Performance of Three Commercial SARS‐CoV‐2 Rapid Antigen Tests for Community-Dwelling Individuals in a Tropical Setting
title Clinical Performance of Three Commercial SARS‐CoV‐2 Rapid Antigen Tests for Community-Dwelling Individuals in a Tropical Setting
title_full Clinical Performance of Three Commercial SARS‐CoV‐2 Rapid Antigen Tests for Community-Dwelling Individuals in a Tropical Setting
title_fullStr Clinical Performance of Three Commercial SARS‐CoV‐2 Rapid Antigen Tests for Community-Dwelling Individuals in a Tropical Setting
title_full_unstemmed Clinical Performance of Three Commercial SARS‐CoV‐2 Rapid Antigen Tests for Community-Dwelling Individuals in a Tropical Setting
title_short Clinical Performance of Three Commercial SARS‐CoV‐2 Rapid Antigen Tests for Community-Dwelling Individuals in a Tropical Setting
title_sort clinical performance of three commercial sars‐cov‐2 rapid antigen tests for community-dwelling individuals in a tropical setting
topic Cellular and Infection Microbiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9294138/
https://www.ncbi.nlm.nih.gov/pubmed/35865818
http://dx.doi.org/10.3389/fcimb.2022.832235
work_keys_str_mv AT moralesjadandiana clinicalperformanceofthreecommercialsarscov2rapidantigentestsforcommunitydwellingindividualsinatropicalsetting
AT viteridavilacarolina clinicalperformanceofthreecommercialsarscov2rapidantigentestsforcommunitydwellingindividualsinatropicalsetting
AT castrorodriguezbernardo clinicalperformanceofthreecommercialsarscov2rapidantigentestsforcommunitydwellingindividualsinatropicalsetting
AT vallejojanetaalexanderpaolo clinicalperformanceofthreecommercialsarscov2rapidantigentestsforcommunitydwellingindividualsinatropicalsetting
AT riveraoliveroismara clinicalperformanceofthreecommercialsarscov2rapidantigentestsforcommunitydwellingindividualsinatropicalsetting
AT perezfranklin clinicalperformanceofthreecommercialsarscov2rapidantigentestsforcommunitydwellingindividualsinatropicalsetting
AT garciabereguiainmiguelangel clinicalperformanceofthreecommercialsarscov2rapidantigentestsforcommunitydwellingindividualsinatropicalsetting