CT-Based Analysis of Left Ventricular Hemodynamics Using Statistical Shape Modeling and Computational Fluid Dynamics

BACKGROUND: Cardiac computed tomography (CCT) based computational fluid dynamics (CFD) allows to assess intracardiac flow features, which are hypothesized as an early predictor for heart diseases and may support treatment decisions. However, the understanding of intracardiac flow is challenging due...

Descripción completa

Detalles Bibliográficos
Autores principales: Goubergrits, Leonid, Vellguth, Katharina, Obermeier, Lukas, Schlief, Adriano, Tautz, Lennart, Bruening, Jan, Lamecker, Hans, Szengel, Angelika, Nemchyna, Olena, Knosalla, Christoph, Kuehne, Titus, Solowjowa, Natalia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9294248/
https://www.ncbi.nlm.nih.gov/pubmed/35865389
http://dx.doi.org/10.3389/fcvm.2022.901902
_version_ 1784749808332832768
author Goubergrits, Leonid
Vellguth, Katharina
Obermeier, Lukas
Schlief, Adriano
Tautz, Lennart
Bruening, Jan
Lamecker, Hans
Szengel, Angelika
Nemchyna, Olena
Knosalla, Christoph
Kuehne, Titus
Solowjowa, Natalia
author_facet Goubergrits, Leonid
Vellguth, Katharina
Obermeier, Lukas
Schlief, Adriano
Tautz, Lennart
Bruening, Jan
Lamecker, Hans
Szengel, Angelika
Nemchyna, Olena
Knosalla, Christoph
Kuehne, Titus
Solowjowa, Natalia
author_sort Goubergrits, Leonid
collection PubMed
description BACKGROUND: Cardiac computed tomography (CCT) based computational fluid dynamics (CFD) allows to assess intracardiac flow features, which are hypothesized as an early predictor for heart diseases and may support treatment decisions. However, the understanding of intracardiac flow is challenging due to high variability in heart shapes and contractility. Using statistical shape modeling (SSM) in combination with CFD facilitates an intracardiac flow analysis. The aim of this study is to prove the usability of a new approach to describe various cohorts. MATERIALS AND METHODS: CCT data of 125 patients (mean age: 60.6 ± 10.0 years, 16.8% woman) were used to generate SSMs representing aneurysmatic and non-aneurysmatic left ventricles (LVs). Using SSMs, seven group-averaged LV shapes and contraction fields were generated: four representing patients with and without aneurysms and with mild or severe mitral regurgitation (MR), and three distinguishing aneurysmatic patients with true, intermediate aneurysms, and globally hypokinetic LVs. End-diastolic LV volumes of the groups varied between 258 and 347 ml, whereas ejection fractions varied between 21 and 26%. MR degrees varied from 1.0 to 2.5. Prescribed motion CFD was used to simulate intracardiac flow, which was analyzed regarding large-scale flow features, kinetic energy, washout, and pressure gradients. RESULTS: SSMs of aneurysmatic and non-aneurysmatic LVs were generated. Differences in shapes and contractility were found in the first three shape modes. Ninety percent of the cumulative shape variance is described with approximately 30 modes. A comparison of hemodynamics between all groups found shape-, contractility- and MR-dependent differences. Disturbed blood washout in the apex region was found in the aneurysmatic cases. With increasing MR, the diastolic jet becomes less coherent, whereas energy dissipation increases by decreasing kinetic energy. The poorest blood washout was found for the globally hypokinetic group, whereas the weakest blood washout in the apex region was found for the true aneurysm group. CONCLUSION: The proposed CCT-based analysis of hemodynamics combining CFD with SSM seems promising to facilitate the analysis of intracardiac flow, thus increasing the value of CCT for diagnostic and treatment decisions. With further enhancement of the computational approach, the methodology has the potential to be embedded in clinical routine workflows and support clinicians.
format Online
Article
Text
id pubmed-9294248
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-92942482022-07-20 CT-Based Analysis of Left Ventricular Hemodynamics Using Statistical Shape Modeling and Computational Fluid Dynamics Goubergrits, Leonid Vellguth, Katharina Obermeier, Lukas Schlief, Adriano Tautz, Lennart Bruening, Jan Lamecker, Hans Szengel, Angelika Nemchyna, Olena Knosalla, Christoph Kuehne, Titus Solowjowa, Natalia Front Cardiovasc Med Cardiovascular Medicine BACKGROUND: Cardiac computed tomography (CCT) based computational fluid dynamics (CFD) allows to assess intracardiac flow features, which are hypothesized as an early predictor for heart diseases and may support treatment decisions. However, the understanding of intracardiac flow is challenging due to high variability in heart shapes and contractility. Using statistical shape modeling (SSM) in combination with CFD facilitates an intracardiac flow analysis. The aim of this study is to prove the usability of a new approach to describe various cohorts. MATERIALS AND METHODS: CCT data of 125 patients (mean age: 60.6 ± 10.0 years, 16.8% woman) were used to generate SSMs representing aneurysmatic and non-aneurysmatic left ventricles (LVs). Using SSMs, seven group-averaged LV shapes and contraction fields were generated: four representing patients with and without aneurysms and with mild or severe mitral regurgitation (MR), and three distinguishing aneurysmatic patients with true, intermediate aneurysms, and globally hypokinetic LVs. End-diastolic LV volumes of the groups varied between 258 and 347 ml, whereas ejection fractions varied between 21 and 26%. MR degrees varied from 1.0 to 2.5. Prescribed motion CFD was used to simulate intracardiac flow, which was analyzed regarding large-scale flow features, kinetic energy, washout, and pressure gradients. RESULTS: SSMs of aneurysmatic and non-aneurysmatic LVs were generated. Differences in shapes and contractility were found in the first three shape modes. Ninety percent of the cumulative shape variance is described with approximately 30 modes. A comparison of hemodynamics between all groups found shape-, contractility- and MR-dependent differences. Disturbed blood washout in the apex region was found in the aneurysmatic cases. With increasing MR, the diastolic jet becomes less coherent, whereas energy dissipation increases by decreasing kinetic energy. The poorest blood washout was found for the globally hypokinetic group, whereas the weakest blood washout in the apex region was found for the true aneurysm group. CONCLUSION: The proposed CCT-based analysis of hemodynamics combining CFD with SSM seems promising to facilitate the analysis of intracardiac flow, thus increasing the value of CCT for diagnostic and treatment decisions. With further enhancement of the computational approach, the methodology has the potential to be embedded in clinical routine workflows and support clinicians. Frontiers Media S.A. 2022-07-05 /pmc/articles/PMC9294248/ /pubmed/35865389 http://dx.doi.org/10.3389/fcvm.2022.901902 Text en Copyright © 2022 Goubergrits, Vellguth, Obermeier, Schlief, Tautz, Bruening, Lamecker, Szengel, Nemchyna, Knosalla, Kuehne and Solowjowa. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Goubergrits, Leonid
Vellguth, Katharina
Obermeier, Lukas
Schlief, Adriano
Tautz, Lennart
Bruening, Jan
Lamecker, Hans
Szengel, Angelika
Nemchyna, Olena
Knosalla, Christoph
Kuehne, Titus
Solowjowa, Natalia
CT-Based Analysis of Left Ventricular Hemodynamics Using Statistical Shape Modeling and Computational Fluid Dynamics
title CT-Based Analysis of Left Ventricular Hemodynamics Using Statistical Shape Modeling and Computational Fluid Dynamics
title_full CT-Based Analysis of Left Ventricular Hemodynamics Using Statistical Shape Modeling and Computational Fluid Dynamics
title_fullStr CT-Based Analysis of Left Ventricular Hemodynamics Using Statistical Shape Modeling and Computational Fluid Dynamics
title_full_unstemmed CT-Based Analysis of Left Ventricular Hemodynamics Using Statistical Shape Modeling and Computational Fluid Dynamics
title_short CT-Based Analysis of Left Ventricular Hemodynamics Using Statistical Shape Modeling and Computational Fluid Dynamics
title_sort ct-based analysis of left ventricular hemodynamics using statistical shape modeling and computational fluid dynamics
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9294248/
https://www.ncbi.nlm.nih.gov/pubmed/35865389
http://dx.doi.org/10.3389/fcvm.2022.901902
work_keys_str_mv AT goubergritsleonid ctbasedanalysisofleftventricularhemodynamicsusingstatisticalshapemodelingandcomputationalfluiddynamics
AT vellguthkatharina ctbasedanalysisofleftventricularhemodynamicsusingstatisticalshapemodelingandcomputationalfluiddynamics
AT obermeierlukas ctbasedanalysisofleftventricularhemodynamicsusingstatisticalshapemodelingandcomputationalfluiddynamics
AT schliefadriano ctbasedanalysisofleftventricularhemodynamicsusingstatisticalshapemodelingandcomputationalfluiddynamics
AT tautzlennart ctbasedanalysisofleftventricularhemodynamicsusingstatisticalshapemodelingandcomputationalfluiddynamics
AT brueningjan ctbasedanalysisofleftventricularhemodynamicsusingstatisticalshapemodelingandcomputationalfluiddynamics
AT lameckerhans ctbasedanalysisofleftventricularhemodynamicsusingstatisticalshapemodelingandcomputationalfluiddynamics
AT szengelangelika ctbasedanalysisofleftventricularhemodynamicsusingstatisticalshapemodelingandcomputationalfluiddynamics
AT nemchynaolena ctbasedanalysisofleftventricularhemodynamicsusingstatisticalshapemodelingandcomputationalfluiddynamics
AT knosallachristoph ctbasedanalysisofleftventricularhemodynamicsusingstatisticalshapemodelingandcomputationalfluiddynamics
AT kuehnetitus ctbasedanalysisofleftventricularhemodynamicsusingstatisticalshapemodelingandcomputationalfluiddynamics
AT solowjowanatalia ctbasedanalysisofleftventricularhemodynamicsusingstatisticalshapemodelingandcomputationalfluiddynamics