Cargando…
Feasibility and discriminatory value of tissue motion annular displacement in sepsis-induced cardiomyopathy: a single-center retrospective observational study
BACKGROUND: There is no formal diagnostic criterion for sepsis-induced cardiomyopathy (SICM), but left ventricular ejection fraction (LVEF) < 50% was the most commonly used standard. Tissue motion annular displacement (TMAD) is a novel speckle tracking indicator to quickly assess LV longitudinal...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9295263/ https://www.ncbi.nlm.nih.gov/pubmed/35851427 http://dx.doi.org/10.1186/s13054-022-04095-w |
_version_ | 1784750024972828672 |
---|---|
author | Song, Jieqiong Yao, Yao Lin, Shilong He, Yizhou Zhu, Duming Zhong, Ming |
author_facet | Song, Jieqiong Yao, Yao Lin, Shilong He, Yizhou Zhu, Duming Zhong, Ming |
author_sort | Song, Jieqiong |
collection | PubMed |
description | BACKGROUND: There is no formal diagnostic criterion for sepsis-induced cardiomyopathy (SICM), but left ventricular ejection fraction (LVEF) < 50% was the most commonly used standard. Tissue motion annular displacement (TMAD) is a novel speckle tracking indicator to quickly assess LV longitudinal systolic function. This study aimed to evaluate the feasibility and discriminatory value of TMAD for predicting SICM, as well as prognostic value of TMAD for mortality. METHODS: We conducted a single-center retrospective observational study in patients with sepsis or septic shock who underwent echocardiography examination within the first 24 h after admission. Basic clinical information and conventional echocardiographic data, including mitral annular plane systolic excursion (MAPSE), were collected. Based on speckle tracking echocardiography (STE), global longitudinal strain (GLS) and TMAD were, respectively, performed offline. The parameters acquisition rate, inter- and intra-observer reliability, time consumed for measurement were assessed for the feasibility analysis. Areas under the receiver operating characteristic curves (AUROC) values were calculated to assess the discriminatory value of TMAD/GLS/MAPSE for predicting SICM, defined as LVEF < 50%. Kaplan–Meier survival curve analysis was performed according to the cutoff values in predicting SICM. Cox proportional hazards model was performed to determine the risk factors for 28d and in-hospital mortality. RESULTS: A total of 143 patients were enrolled in this study. Compared with LVEF, GLS or MAPSE, TMAD exhibited the highest parameter acquisition rate, intra- and inter-observer reliability. The mean time for offline analyses with TMAD was significantly shorter than that with LVEF or GLS (p < 0.05). According to the AUROC analysis, TMADMid presented an excellent discriminatory value for predicting SICM (AUROC > 0.9). Patients with lower TMADMid (< 9.75 mm) had significantly higher 28d and in-hospital mortality (both p < 0.05). The multivariate Cox proportional hazards model revealed that BMI and SOFA were the independent risk factors for 28d and in-hospital mortality in sepsis cases, but TMAD was not. CONCLUSION: STE-based TMAD is a novel and feasible technology with promising discriminatory value for predicting SICM with LVEF < 50%. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13054-022-04095-w. |
format | Online Article Text |
id | pubmed-9295263 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-92952632022-07-20 Feasibility and discriminatory value of tissue motion annular displacement in sepsis-induced cardiomyopathy: a single-center retrospective observational study Song, Jieqiong Yao, Yao Lin, Shilong He, Yizhou Zhu, Duming Zhong, Ming Crit Care Research BACKGROUND: There is no formal diagnostic criterion for sepsis-induced cardiomyopathy (SICM), but left ventricular ejection fraction (LVEF) < 50% was the most commonly used standard. Tissue motion annular displacement (TMAD) is a novel speckle tracking indicator to quickly assess LV longitudinal systolic function. This study aimed to evaluate the feasibility and discriminatory value of TMAD for predicting SICM, as well as prognostic value of TMAD for mortality. METHODS: We conducted a single-center retrospective observational study in patients with sepsis or septic shock who underwent echocardiography examination within the first 24 h after admission. Basic clinical information and conventional echocardiographic data, including mitral annular plane systolic excursion (MAPSE), were collected. Based on speckle tracking echocardiography (STE), global longitudinal strain (GLS) and TMAD were, respectively, performed offline. The parameters acquisition rate, inter- and intra-observer reliability, time consumed for measurement were assessed for the feasibility analysis. Areas under the receiver operating characteristic curves (AUROC) values were calculated to assess the discriminatory value of TMAD/GLS/MAPSE for predicting SICM, defined as LVEF < 50%. Kaplan–Meier survival curve analysis was performed according to the cutoff values in predicting SICM. Cox proportional hazards model was performed to determine the risk factors for 28d and in-hospital mortality. RESULTS: A total of 143 patients were enrolled in this study. Compared with LVEF, GLS or MAPSE, TMAD exhibited the highest parameter acquisition rate, intra- and inter-observer reliability. The mean time for offline analyses with TMAD was significantly shorter than that with LVEF or GLS (p < 0.05). According to the AUROC analysis, TMADMid presented an excellent discriminatory value for predicting SICM (AUROC > 0.9). Patients with lower TMADMid (< 9.75 mm) had significantly higher 28d and in-hospital mortality (both p < 0.05). The multivariate Cox proportional hazards model revealed that BMI and SOFA were the independent risk factors for 28d and in-hospital mortality in sepsis cases, but TMAD was not. CONCLUSION: STE-based TMAD is a novel and feasible technology with promising discriminatory value for predicting SICM with LVEF < 50%. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13054-022-04095-w. BioMed Central 2022-07-18 /pmc/articles/PMC9295263/ /pubmed/35851427 http://dx.doi.org/10.1186/s13054-022-04095-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Song, Jieqiong Yao, Yao Lin, Shilong He, Yizhou Zhu, Duming Zhong, Ming Feasibility and discriminatory value of tissue motion annular displacement in sepsis-induced cardiomyopathy: a single-center retrospective observational study |
title | Feasibility and discriminatory value of tissue motion annular displacement in sepsis-induced cardiomyopathy: a single-center retrospective observational study |
title_full | Feasibility and discriminatory value of tissue motion annular displacement in sepsis-induced cardiomyopathy: a single-center retrospective observational study |
title_fullStr | Feasibility and discriminatory value of tissue motion annular displacement in sepsis-induced cardiomyopathy: a single-center retrospective observational study |
title_full_unstemmed | Feasibility and discriminatory value of tissue motion annular displacement in sepsis-induced cardiomyopathy: a single-center retrospective observational study |
title_short | Feasibility and discriminatory value of tissue motion annular displacement in sepsis-induced cardiomyopathy: a single-center retrospective observational study |
title_sort | feasibility and discriminatory value of tissue motion annular displacement in sepsis-induced cardiomyopathy: a single-center retrospective observational study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9295263/ https://www.ncbi.nlm.nih.gov/pubmed/35851427 http://dx.doi.org/10.1186/s13054-022-04095-w |
work_keys_str_mv | AT songjieqiong feasibilityanddiscriminatoryvalueoftissuemotionannulardisplacementinsepsisinducedcardiomyopathyasinglecenterretrospectiveobservationalstudy AT yaoyao feasibilityanddiscriminatoryvalueoftissuemotionannulardisplacementinsepsisinducedcardiomyopathyasinglecenterretrospectiveobservationalstudy AT linshilong feasibilityanddiscriminatoryvalueoftissuemotionannulardisplacementinsepsisinducedcardiomyopathyasinglecenterretrospectiveobservationalstudy AT heyizhou feasibilityanddiscriminatoryvalueoftissuemotionannulardisplacementinsepsisinducedcardiomyopathyasinglecenterretrospectiveobservationalstudy AT zhuduming feasibilityanddiscriminatoryvalueoftissuemotionannulardisplacementinsepsisinducedcardiomyopathyasinglecenterretrospectiveobservationalstudy AT zhongming feasibilityanddiscriminatoryvalueoftissuemotionannulardisplacementinsepsisinducedcardiomyopathyasinglecenterretrospectiveobservationalstudy |