Cushioned on the way up, controlled on the way down during resuscitative endovascular balloon occlusion of the aorta (REBOA): investigating a novel compliant balloon design for optimizing safe overinflation combined with partial REBOA ability

BACKGROUND: There are a variety of devices capable of performing resuscitative endovascular balloon occlusion of the aorta (REBOA), with most containing compliant balloon material. While compliant material is ideal for balloon inflation due to its “cushioning” effect, it can be problematic to “contr...

Descripción completa

Detalles Bibliográficos
Autores principales: Power, Adam, Parekh, Asha, Parry, Neil, Moore, Laura J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9295662/
https://www.ncbi.nlm.nih.gov/pubmed/35949246
http://dx.doi.org/10.1136/tsaco-2022-000948
_version_ 1784750095345909760
author Power, Adam
Parekh, Asha
Parry, Neil
Moore, Laura J
author_facet Power, Adam
Parekh, Asha
Parry, Neil
Moore, Laura J
author_sort Power, Adam
collection PubMed
description BACKGROUND: There are a variety of devices capable of performing resuscitative endovascular balloon occlusion of the aorta (REBOA), with most containing compliant balloon material. While compliant material is ideal for balloon inflation due to its “cushioning” effect, it can be problematic to “control” during deflation. The COBRA-OS (Control Of Bleeding, Resuscitation, Arterial Occlusion System) was designed to optimize inflation and deflation of its compliant balloon and was tested in vitro and in vivo with respect to its overinflation and partial REBOA abilities. METHODS: For overinflation, the COBRA-OS was inflated in three differently sized inner diameter (ID) vinyl tubes until balloon rupture. It was then overinflated in six harvested swine aortas and in all three REBOA zones of three anesthetized swine. For partial REBOA, the COBRA-OS underwent incremental deflation in a pulsatile benchtop aortic model and in zone 1 of three anesthetized swine. RESULTS: For overinflation, compared with the known aortic rupture threshold of 4 atm, the COBRA-OS exceeded this value in only the smallest of the vinyl tubes: 8 mm ID tube, 6.5 atm; 9.5 mm ID tube, 3.5 atm; 13 mm ID tube, 1.5 atm. It also demonstrated greater than 500% overinflation ability without aortic damage in vitro and caused no aortic damage when inflated to maximum inflation volume in vivo. For partial REBOA, the COBRA-OS was able to provide a titration window of between 3 mL and 4 mL in both the pulsatile vascular model (3.4±0.12 mL) and anesthetized swine (3.8±0.35 mL). DISCUSSION: The COBRA-OS demonstrated the ability to have a cushioning effect during inflation combined with titration control on deflation in vitro and in vivo. This study suggests that despite its balloon compliance, both safe overinflation and partial REBOA can be successfully achieved with the COBRA-OS. LEVEL OF EVIDENCE: Basic science.
format Online
Article
Text
id pubmed-9295662
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-92956622022-08-09 Cushioned on the way up, controlled on the way down during resuscitative endovascular balloon occlusion of the aorta (REBOA): investigating a novel compliant balloon design for optimizing safe overinflation combined with partial REBOA ability Power, Adam Parekh, Asha Parry, Neil Moore, Laura J Trauma Surg Acute Care Open Original Research BACKGROUND: There are a variety of devices capable of performing resuscitative endovascular balloon occlusion of the aorta (REBOA), with most containing compliant balloon material. While compliant material is ideal for balloon inflation due to its “cushioning” effect, it can be problematic to “control” during deflation. The COBRA-OS (Control Of Bleeding, Resuscitation, Arterial Occlusion System) was designed to optimize inflation and deflation of its compliant balloon and was tested in vitro and in vivo with respect to its overinflation and partial REBOA abilities. METHODS: For overinflation, the COBRA-OS was inflated in three differently sized inner diameter (ID) vinyl tubes until balloon rupture. It was then overinflated in six harvested swine aortas and in all three REBOA zones of three anesthetized swine. For partial REBOA, the COBRA-OS underwent incremental deflation in a pulsatile benchtop aortic model and in zone 1 of three anesthetized swine. RESULTS: For overinflation, compared with the known aortic rupture threshold of 4 atm, the COBRA-OS exceeded this value in only the smallest of the vinyl tubes: 8 mm ID tube, 6.5 atm; 9.5 mm ID tube, 3.5 atm; 13 mm ID tube, 1.5 atm. It also demonstrated greater than 500% overinflation ability without aortic damage in vitro and caused no aortic damage when inflated to maximum inflation volume in vivo. For partial REBOA, the COBRA-OS was able to provide a titration window of between 3 mL and 4 mL in both the pulsatile vascular model (3.4±0.12 mL) and anesthetized swine (3.8±0.35 mL). DISCUSSION: The COBRA-OS demonstrated the ability to have a cushioning effect during inflation combined with titration control on deflation in vitro and in vivo. This study suggests that despite its balloon compliance, both safe overinflation and partial REBOA can be successfully achieved with the COBRA-OS. LEVEL OF EVIDENCE: Basic science. BMJ Publishing Group 2022-07-14 /pmc/articles/PMC9295662/ /pubmed/35949246 http://dx.doi.org/10.1136/tsaco-2022-000948 Text en © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Original Research
Power, Adam
Parekh, Asha
Parry, Neil
Moore, Laura J
Cushioned on the way up, controlled on the way down during resuscitative endovascular balloon occlusion of the aorta (REBOA): investigating a novel compliant balloon design for optimizing safe overinflation combined with partial REBOA ability
title Cushioned on the way up, controlled on the way down during resuscitative endovascular balloon occlusion of the aorta (REBOA): investigating a novel compliant balloon design for optimizing safe overinflation combined with partial REBOA ability
title_full Cushioned on the way up, controlled on the way down during resuscitative endovascular balloon occlusion of the aorta (REBOA): investigating a novel compliant balloon design for optimizing safe overinflation combined with partial REBOA ability
title_fullStr Cushioned on the way up, controlled on the way down during resuscitative endovascular balloon occlusion of the aorta (REBOA): investigating a novel compliant balloon design for optimizing safe overinflation combined with partial REBOA ability
title_full_unstemmed Cushioned on the way up, controlled on the way down during resuscitative endovascular balloon occlusion of the aorta (REBOA): investigating a novel compliant balloon design for optimizing safe overinflation combined with partial REBOA ability
title_short Cushioned on the way up, controlled on the way down during resuscitative endovascular balloon occlusion of the aorta (REBOA): investigating a novel compliant balloon design for optimizing safe overinflation combined with partial REBOA ability
title_sort cushioned on the way up, controlled on the way down during resuscitative endovascular balloon occlusion of the aorta (reboa): investigating a novel compliant balloon design for optimizing safe overinflation combined with partial reboa ability
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9295662/
https://www.ncbi.nlm.nih.gov/pubmed/35949246
http://dx.doi.org/10.1136/tsaco-2022-000948
work_keys_str_mv AT poweradam cushionedonthewayupcontrolledonthewaydownduringresuscitativeendovascularballoonocclusionoftheaortareboainvestigatinganovelcompliantballoondesignforoptimizingsafeoverinflationcombinedwithpartialreboaability
AT parekhasha cushionedonthewayupcontrolledonthewaydownduringresuscitativeendovascularballoonocclusionoftheaortareboainvestigatinganovelcompliantballoondesignforoptimizingsafeoverinflationcombinedwithpartialreboaability
AT parryneil cushionedonthewayupcontrolledonthewaydownduringresuscitativeendovascularballoonocclusionoftheaortareboainvestigatinganovelcompliantballoondesignforoptimizingsafeoverinflationcombinedwithpartialreboaability
AT moorelauraj cushionedonthewayupcontrolledonthewaydownduringresuscitativeendovascularballoonocclusionoftheaortareboainvestigatinganovelcompliantballoondesignforoptimizingsafeoverinflationcombinedwithpartialreboaability