Permanent pacing in a very long‐term follow‐up after orthotopic heart transplantation: A matter of when or why?

BACKGROUND: Orthotopic heart transplantation (OHT) is associated with a high incidence of conduction disturbances (CD) leading to permanent pacemaker (PPM) implantation. However, the improved posttransplant survival raises the question about the pacemaker dependence (PD) in a prolonged follow‐up. HY...

Descripción completa

Detalles Bibliográficos
Autores principales: Alyaydin, Emyal, Pogoda, Christian, Dell'Aquila, Angelo, Frommeyer, Gerrit, Sindermann, Juergen R., Reinecke, Holger, Tuleta, Izabela