Cargando…

Dural puncture epidural technique provides better anesthesia quality in repeat cesarean delivery than epidural technique: Randomized controlled study

BACKGROUND: Repeat cesarean deliverys involve a longer surgery and more severe visceral traction than primary cesarean deliverys. The dural puncture epidural (DPE) technique provides faster and more effective analgesia for labor, but there is no sufficient evidence to indicate whether it is suitable...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Sheng-You, He, Yan, Zhu, Hai-Juan, Han, Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9297399/
https://www.ncbi.nlm.nih.gov/pubmed/36051113
http://dx.doi.org/10.12998/wjcc.v10.i20.6890
_version_ 1784750467602972672
author Wang, Sheng-You
He, Yan
Zhu, Hai-Juan
Han, Bo
author_facet Wang, Sheng-You
He, Yan
Zhu, Hai-Juan
Han, Bo
author_sort Wang, Sheng-You
collection PubMed
description BACKGROUND: Repeat cesarean deliverys involve a longer surgery and more severe visceral traction than primary cesarean deliverys. The dural puncture epidural (DPE) technique provides faster and more effective analgesia for labor, but there is no sufficient evidence to indicate whether it is suitable for parturients undergoing repeat cesarean delivery. AIM: To determine the efficacy and safety of the DPE anesthesia technique in patients undergoing repeat cesarean delivery. METHODS: Patients undergoing repeat cesarean delivery were randomly divided into the DPE and epidural anesthesia (EA) groups. A 25-G spinal needle was used for dural puncture via a 19-G epidural needle. The patients in the two groups were injected with 5 mL of 2% lidocaine followed by 15 mL of a mixture of 1% lidocaine + 0.5% ropivacaine as the epidural dosage. The primary outcome was the onset time of sensory block to the T6 dermatome level and the sensory and motor block degree. RESULTS: A total of 115 women were included (EA: 57, DPE: 58). The mean time to sensory block to the T6 Level was significantly shorter in the DPE group than in the EA group (14.7 min vs 16.6 min; 95% confidence interval, 13.9 to 15.4 vs 15.8 to 17.4; P = 0.001). The cranial sensory block level was significantly higher at 5, 10, and 15 min after the initial dose in the DPE group than in the EA group (P < 0.05). The sacral sensory block level was significantly higher and the modified bromage score was significantly lower in the DPE group at each time point (P < 0.05). Adverse effects and neonatal outcomes were comparable between the two groups (P > 0.05). CONCLUSION: The DPE technique provided higher-quality anesthesia than the EA technique, with a rapid onset of surgical anesthesia, better cranial and sacral sensory block spread and a higher motor block degree, without increasing the incidence of maternal or fetal side effects in patients undergoing repeat cesarean delivery.
format Online
Article
Text
id pubmed-9297399
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-92973992022-08-31 Dural puncture epidural technique provides better anesthesia quality in repeat cesarean delivery than epidural technique: Randomized controlled study Wang, Sheng-You He, Yan Zhu, Hai-Juan Han, Bo World J Clin Cases Randomized Controlled Trial BACKGROUND: Repeat cesarean deliverys involve a longer surgery and more severe visceral traction than primary cesarean deliverys. The dural puncture epidural (DPE) technique provides faster and more effective analgesia for labor, but there is no sufficient evidence to indicate whether it is suitable for parturients undergoing repeat cesarean delivery. AIM: To determine the efficacy and safety of the DPE anesthesia technique in patients undergoing repeat cesarean delivery. METHODS: Patients undergoing repeat cesarean delivery were randomly divided into the DPE and epidural anesthesia (EA) groups. A 25-G spinal needle was used for dural puncture via a 19-G epidural needle. The patients in the two groups were injected with 5 mL of 2% lidocaine followed by 15 mL of a mixture of 1% lidocaine + 0.5% ropivacaine as the epidural dosage. The primary outcome was the onset time of sensory block to the T6 dermatome level and the sensory and motor block degree. RESULTS: A total of 115 women were included (EA: 57, DPE: 58). The mean time to sensory block to the T6 Level was significantly shorter in the DPE group than in the EA group (14.7 min vs 16.6 min; 95% confidence interval, 13.9 to 15.4 vs 15.8 to 17.4; P = 0.001). The cranial sensory block level was significantly higher at 5, 10, and 15 min after the initial dose in the DPE group than in the EA group (P < 0.05). The sacral sensory block level was significantly higher and the modified bromage score was significantly lower in the DPE group at each time point (P < 0.05). Adverse effects and neonatal outcomes were comparable between the two groups (P > 0.05). CONCLUSION: The DPE technique provided higher-quality anesthesia than the EA technique, with a rapid onset of surgical anesthesia, better cranial and sacral sensory block spread and a higher motor block degree, without increasing the incidence of maternal or fetal side effects in patients undergoing repeat cesarean delivery. Baishideng Publishing Group Inc 2022-07-16 2022-07-16 /pmc/articles/PMC9297399/ /pubmed/36051113 http://dx.doi.org/10.12998/wjcc.v10.i20.6890 Text en ©The Author(s) 2022. Published by Baishideng Publishing Group Inc. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/Licenses/by-nc/4.0/
spellingShingle Randomized Controlled Trial
Wang, Sheng-You
He, Yan
Zhu, Hai-Juan
Han, Bo
Dural puncture epidural technique provides better anesthesia quality in repeat cesarean delivery than epidural technique: Randomized controlled study
title Dural puncture epidural technique provides better anesthesia quality in repeat cesarean delivery than epidural technique: Randomized controlled study
title_full Dural puncture epidural technique provides better anesthesia quality in repeat cesarean delivery than epidural technique: Randomized controlled study
title_fullStr Dural puncture epidural technique provides better anesthesia quality in repeat cesarean delivery than epidural technique: Randomized controlled study
title_full_unstemmed Dural puncture epidural technique provides better anesthesia quality in repeat cesarean delivery than epidural technique: Randomized controlled study
title_short Dural puncture epidural technique provides better anesthesia quality in repeat cesarean delivery than epidural technique: Randomized controlled study
title_sort dural puncture epidural technique provides better anesthesia quality in repeat cesarean delivery than epidural technique: randomized controlled study
topic Randomized Controlled Trial
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9297399/
https://www.ncbi.nlm.nih.gov/pubmed/36051113
http://dx.doi.org/10.12998/wjcc.v10.i20.6890
work_keys_str_mv AT wangshengyou duralpunctureepiduraltechniqueprovidesbetteranesthesiaqualityinrepeatcesareandeliverythanepiduraltechniquerandomizedcontrolledstudy
AT heyan duralpunctureepiduraltechniqueprovidesbetteranesthesiaqualityinrepeatcesareandeliverythanepiduraltechniquerandomizedcontrolledstudy
AT zhuhaijuan duralpunctureepiduraltechniqueprovidesbetteranesthesiaqualityinrepeatcesareandeliverythanepiduraltechniquerandomizedcontrolledstudy
AT hanbo duralpunctureepiduraltechniqueprovidesbetteranesthesiaqualityinrepeatcesareandeliverythanepiduraltechniquerandomizedcontrolledstudy