Cargando…

Insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system

PURPOSE: To demonstrate the capability of insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system. METHODS: Insertable inductively coupled volume coils with diameters of 26 and 64 mm (D26 and D64 coils) targeted for monkey and mouse brain specimen sizes were designe...

Descripción completa

Detalles Bibliográficos
Autores principales: Okada, Tomohisa, Handa, Shinya, Ding, Bill, Urayama, Shin‐ichi, Fujimoto, Koji, Shima, Atsushi, Yoshii, Daisuke, Ayaki, Takashi, Sawamoto, Nobukatsu, Takahashi, Ryosuke, Onoe, Hirotaka, Isa, Tadashi, Petropoulos, Labros
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9297907/
https://www.ncbi.nlm.nih.gov/pubmed/34719801
http://dx.doi.org/10.1002/mrm.29062
_version_ 1784750578566430720
author Okada, Tomohisa
Handa, Shinya
Ding, Bill
Urayama, Shin‐ichi
Fujimoto, Koji
Shima, Atsushi
Yoshii, Daisuke
Ayaki, Takashi
Sawamoto, Nobukatsu
Takahashi, Ryosuke
Onoe, Hirotaka
Isa, Tadashi
Petropoulos, Labros
author_facet Okada, Tomohisa
Handa, Shinya
Ding, Bill
Urayama, Shin‐ichi
Fujimoto, Koji
Shima, Atsushi
Yoshii, Daisuke
Ayaki, Takashi
Sawamoto, Nobukatsu
Takahashi, Ryosuke
Onoe, Hirotaka
Isa, Tadashi
Petropoulos, Labros
author_sort Okada, Tomohisa
collection PubMed
description PURPOSE: To demonstrate the capability of insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system. METHODS: Insertable inductively coupled volume coils with diameters of 26 and 64 mm (D26 and D64 coils) targeted for monkey and mouse brain specimen sizes were designed and fabricated. These coils were placed inside the imaging volume of a transmit/receive knee coil without wired connections to the main system. Signal‐to‐noise ratio (SNR) evaluations were conducted with and without the insertable coils, and the g‐factor maps of parallel imaging (PI) were also calculated for the D64 coil. Brain specimens were imaged using 3D [Formula: see text] ‐weighted images with spatial resolution of isotropic 50 and 160 μm using D26 and D64 coils, respectively. RESULTS: Relative average (SD) SNRs compared with knee coil alone were 12.54 (0.30) and 2.37 (0.05) at the center for the D26 and D64 coils, respectively. The mean g‐factors of PI with the D64 coil for the factor of 2 were less than 1.1 in the left‐right and anterior‐posterior directions, and around 1.5 in the superior‐inferior direction or when the PI factor of 3 was used. Acceleration in two directions showed lower g‐factors but suffered from intrinsic low SNR. Representative [Formula: see text] ‐weighted images of the specimen showed structural details. CONCLUSION: Inductively coupled small diameter coils insertable to the knee coil demonstrated high SNR and modest PI capability. The concept was successfully used to visualize fine structures of the brain specimen. The insertable coils are easy to handle and enable MR microscopy in a human whole‐body 7T MRI system.
format Online
Article
Text
id pubmed-9297907
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-92979072022-07-21 Insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system Okada, Tomohisa Handa, Shinya Ding, Bill Urayama, Shin‐ichi Fujimoto, Koji Shima, Atsushi Yoshii, Daisuke Ayaki, Takashi Sawamoto, Nobukatsu Takahashi, Ryosuke Onoe, Hirotaka Isa, Tadashi Petropoulos, Labros Magn Reson Med Technical Notes—Hardware and Instrumentation PURPOSE: To demonstrate the capability of insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system. METHODS: Insertable inductively coupled volume coils with diameters of 26 and 64 mm (D26 and D64 coils) targeted for monkey and mouse brain specimen sizes were designed and fabricated. These coils were placed inside the imaging volume of a transmit/receive knee coil without wired connections to the main system. Signal‐to‐noise ratio (SNR) evaluations were conducted with and without the insertable coils, and the g‐factor maps of parallel imaging (PI) were also calculated for the D64 coil. Brain specimens were imaged using 3D [Formula: see text] ‐weighted images with spatial resolution of isotropic 50 and 160 μm using D26 and D64 coils, respectively. RESULTS: Relative average (SD) SNRs compared with knee coil alone were 12.54 (0.30) and 2.37 (0.05) at the center for the D26 and D64 coils, respectively. The mean g‐factors of PI with the D64 coil for the factor of 2 were less than 1.1 in the left‐right and anterior‐posterior directions, and around 1.5 in the superior‐inferior direction or when the PI factor of 3 was used. Acceleration in two directions showed lower g‐factors but suffered from intrinsic low SNR. Representative [Formula: see text] ‐weighted images of the specimen showed structural details. CONCLUSION: Inductively coupled small diameter coils insertable to the knee coil demonstrated high SNR and modest PI capability. The concept was successfully used to visualize fine structures of the brain specimen. The insertable coils are easy to handle and enable MR microscopy in a human whole‐body 7T MRI system. John Wiley and Sons Inc. 2021-11-01 2022-03 /pmc/articles/PMC9297907/ /pubmed/34719801 http://dx.doi.org/10.1002/mrm.29062 Text en © 2021 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Technical Notes—Hardware and Instrumentation
Okada, Tomohisa
Handa, Shinya
Ding, Bill
Urayama, Shin‐ichi
Fujimoto, Koji
Shima, Atsushi
Yoshii, Daisuke
Ayaki, Takashi
Sawamoto, Nobukatsu
Takahashi, Ryosuke
Onoe, Hirotaka
Isa, Tadashi
Petropoulos, Labros
Insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system
title Insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system
title_full Insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system
title_fullStr Insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system
title_full_unstemmed Insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system
title_short Insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system
title_sort insertable inductively coupled volumetric coils for mr microscopy in a human 7t mr system
topic Technical Notes—Hardware and Instrumentation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9297907/
https://www.ncbi.nlm.nih.gov/pubmed/34719801
http://dx.doi.org/10.1002/mrm.29062
work_keys_str_mv AT okadatomohisa insertableinductivelycoupledvolumetriccoilsformrmicroscopyinahuman7tmrsystem
AT handashinya insertableinductivelycoupledvolumetriccoilsformrmicroscopyinahuman7tmrsystem
AT dingbill insertableinductivelycoupledvolumetriccoilsformrmicroscopyinahuman7tmrsystem
AT urayamashinichi insertableinductivelycoupledvolumetriccoilsformrmicroscopyinahuman7tmrsystem
AT fujimotokoji insertableinductivelycoupledvolumetriccoilsformrmicroscopyinahuman7tmrsystem
AT shimaatsushi insertableinductivelycoupledvolumetriccoilsformrmicroscopyinahuman7tmrsystem
AT yoshiidaisuke insertableinductivelycoupledvolumetriccoilsformrmicroscopyinahuman7tmrsystem
AT ayakitakashi insertableinductivelycoupledvolumetriccoilsformrmicroscopyinahuman7tmrsystem
AT sawamotonobukatsu insertableinductivelycoupledvolumetriccoilsformrmicroscopyinahuman7tmrsystem
AT takahashiryosuke insertableinductivelycoupledvolumetriccoilsformrmicroscopyinahuman7tmrsystem
AT onoehirotaka insertableinductivelycoupledvolumetriccoilsformrmicroscopyinahuman7tmrsystem
AT isatadashi insertableinductivelycoupledvolumetriccoilsformrmicroscopyinahuman7tmrsystem
AT petropouloslabros insertableinductivelycoupledvolumetriccoilsformrmicroscopyinahuman7tmrsystem