Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study

BACKGROUND AND OBJECTIVES: Breast‐conserving surgery (BCS) is followed by reoperations in approximately 25%. Reoperations lead to an increased risk of infection and wound healing problems as well as a worse cosmetic outcome. Several technical approaches for an intraoperative margin assessment to dec...

Descripción completa

Detalles Bibliográficos
Autores principales: Thill, Marc, Szwarcfiter, Iris, Kelling, Katharina, van Haasteren, Viviane, Kolka, Eyal, Noelke, Josefa, Peles, Zachi, Papa, Moshe, Aulmann, Sebastian, Allweis, Tanir
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9298117/
https://www.ncbi.nlm.nih.gov/pubmed/34724205
http://dx.doi.org/10.1002/jso.26721
_version_ 1784750631648493568
author Thill, Marc
Szwarcfiter, Iris
Kelling, Katharina
van Haasteren, Viviane
Kolka, Eyal
Noelke, Josefa
Peles, Zachi
Papa, Moshe
Aulmann, Sebastian
Allweis, Tanir
author_facet Thill, Marc
Szwarcfiter, Iris
Kelling, Katharina
van Haasteren, Viviane
Kolka, Eyal
Noelke, Josefa
Peles, Zachi
Papa, Moshe
Aulmann, Sebastian
Allweis, Tanir
author_sort Thill, Marc
collection PubMed
description BACKGROUND AND OBJECTIVES: Breast‐conserving surgery (BCS) is followed by reoperations in approximately 25%. Reoperations lead to an increased risk of infection and wound healing problems as well as a worse cosmetic outcome. Several technical approaches for an intraoperative margin assessment to decrease the reoperation rate are under evaluation, some of them are still experimental. METHODS: A prospective single‐arm post‐marketing study with 60 patients undergoing BCS for ductal carcinoma in situ (DCIS) and invasive breast cancer was conducted. The specimen was intraoperatively examined by the ClearSight™ system, a mobile magnetic resonance imaging system that is based on a diffusion‐weighted imaging protocol. However, the results were blinded to the surgeon. RESULTS: The ClearSight™ system was performed for both ductal and lobular breast cancer and DCIS, with a sensitivity of 0.80 (95% confidence interval [CI]: 0.44–0.96) and a specificity of 0.84 (95% CI 0.72–0.92), with an overall diagnostic accuracy of 80%. CONCLUSION: Had the ClearSight™ been known to the surgeon intraoperatively, the reoperation rate would have been reduced by 83% for invasive carcinoma, from 10% to 2%, and 50% for DCIS, from 30% to 15% reoperations. A trial designed to examine the impact on reoperation rates is currently ongoing.
format Online
Article
Text
id pubmed-9298117
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-92981172022-07-21 Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study Thill, Marc Szwarcfiter, Iris Kelling, Katharina van Haasteren, Viviane Kolka, Eyal Noelke, Josefa Peles, Zachi Papa, Moshe Aulmann, Sebastian Allweis, Tanir J Surg Oncol Breast BACKGROUND AND OBJECTIVES: Breast‐conserving surgery (BCS) is followed by reoperations in approximately 25%. Reoperations lead to an increased risk of infection and wound healing problems as well as a worse cosmetic outcome. Several technical approaches for an intraoperative margin assessment to decrease the reoperation rate are under evaluation, some of them are still experimental. METHODS: A prospective single‐arm post‐marketing study with 60 patients undergoing BCS for ductal carcinoma in situ (DCIS) and invasive breast cancer was conducted. The specimen was intraoperatively examined by the ClearSight™ system, a mobile magnetic resonance imaging system that is based on a diffusion‐weighted imaging protocol. However, the results were blinded to the surgeon. RESULTS: The ClearSight™ system was performed for both ductal and lobular breast cancer and DCIS, with a sensitivity of 0.80 (95% confidence interval [CI]: 0.44–0.96) and a specificity of 0.84 (95% CI 0.72–0.92), with an overall diagnostic accuracy of 80%. CONCLUSION: Had the ClearSight™ been known to the surgeon intraoperatively, the reoperation rate would have been reduced by 83% for invasive carcinoma, from 10% to 2%, and 50% for DCIS, from 30% to 15% reoperations. A trial designed to examine the impact on reoperation rates is currently ongoing. John Wiley and Sons Inc. 2021-11-01 2022-03 /pmc/articles/PMC9298117/ /pubmed/34724205 http://dx.doi.org/10.1002/jso.26721 Text en © 2021 The Authors. Journal of Surgical Oncology published by Wiley Periodicals LLC https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Breast
Thill, Marc
Szwarcfiter, Iris
Kelling, Katharina
van Haasteren, Viviane
Kolka, Eyal
Noelke, Josefa
Peles, Zachi
Papa, Moshe
Aulmann, Sebastian
Allweis, Tanir
Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study
title Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study
title_full Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study
title_fullStr Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study
title_full_unstemmed Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study
title_short Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study
title_sort magnetic resonance imaging system for intraoperative margin assessment for dcis and invasive breast cancer using the clearsight™ system in breast‐conserving surgery—results from a postmarketing study
topic Breast
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9298117/
https://www.ncbi.nlm.nih.gov/pubmed/34724205
http://dx.doi.org/10.1002/jso.26721
work_keys_str_mv AT thillmarc magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy
AT szwarcfiteriris magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy
AT kellingkatharina magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy
AT vanhaasterenviviane magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy
AT kolkaeyal magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy
AT noelkejosefa magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy
AT peleszachi magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy
AT papamoshe magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy
AT aulmannsebastian magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy
AT allweistanir magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy