Cargando…
Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study
BACKGROUND AND OBJECTIVES: Breast‐conserving surgery (BCS) is followed by reoperations in approximately 25%. Reoperations lead to an increased risk of infection and wound healing problems as well as a worse cosmetic outcome. Several technical approaches for an intraoperative margin assessment to dec...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9298117/ https://www.ncbi.nlm.nih.gov/pubmed/34724205 http://dx.doi.org/10.1002/jso.26721 |
_version_ | 1784750631648493568 |
---|---|
author | Thill, Marc Szwarcfiter, Iris Kelling, Katharina van Haasteren, Viviane Kolka, Eyal Noelke, Josefa Peles, Zachi Papa, Moshe Aulmann, Sebastian Allweis, Tanir |
author_facet | Thill, Marc Szwarcfiter, Iris Kelling, Katharina van Haasteren, Viviane Kolka, Eyal Noelke, Josefa Peles, Zachi Papa, Moshe Aulmann, Sebastian Allweis, Tanir |
author_sort | Thill, Marc |
collection | PubMed |
description | BACKGROUND AND OBJECTIVES: Breast‐conserving surgery (BCS) is followed by reoperations in approximately 25%. Reoperations lead to an increased risk of infection and wound healing problems as well as a worse cosmetic outcome. Several technical approaches for an intraoperative margin assessment to decrease the reoperation rate are under evaluation, some of them are still experimental. METHODS: A prospective single‐arm post‐marketing study with 60 patients undergoing BCS for ductal carcinoma in situ (DCIS) and invasive breast cancer was conducted. The specimen was intraoperatively examined by the ClearSight™ system, a mobile magnetic resonance imaging system that is based on a diffusion‐weighted imaging protocol. However, the results were blinded to the surgeon. RESULTS: The ClearSight™ system was performed for both ductal and lobular breast cancer and DCIS, with a sensitivity of 0.80 (95% confidence interval [CI]: 0.44–0.96) and a specificity of 0.84 (95% CI 0.72–0.92), with an overall diagnostic accuracy of 80%. CONCLUSION: Had the ClearSight™ been known to the surgeon intraoperatively, the reoperation rate would have been reduced by 83% for invasive carcinoma, from 10% to 2%, and 50% for DCIS, from 30% to 15% reoperations. A trial designed to examine the impact on reoperation rates is currently ongoing. |
format | Online Article Text |
id | pubmed-9298117 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-92981172022-07-21 Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study Thill, Marc Szwarcfiter, Iris Kelling, Katharina van Haasteren, Viviane Kolka, Eyal Noelke, Josefa Peles, Zachi Papa, Moshe Aulmann, Sebastian Allweis, Tanir J Surg Oncol Breast BACKGROUND AND OBJECTIVES: Breast‐conserving surgery (BCS) is followed by reoperations in approximately 25%. Reoperations lead to an increased risk of infection and wound healing problems as well as a worse cosmetic outcome. Several technical approaches for an intraoperative margin assessment to decrease the reoperation rate are under evaluation, some of them are still experimental. METHODS: A prospective single‐arm post‐marketing study with 60 patients undergoing BCS for ductal carcinoma in situ (DCIS) and invasive breast cancer was conducted. The specimen was intraoperatively examined by the ClearSight™ system, a mobile magnetic resonance imaging system that is based on a diffusion‐weighted imaging protocol. However, the results were blinded to the surgeon. RESULTS: The ClearSight™ system was performed for both ductal and lobular breast cancer and DCIS, with a sensitivity of 0.80 (95% confidence interval [CI]: 0.44–0.96) and a specificity of 0.84 (95% CI 0.72–0.92), with an overall diagnostic accuracy of 80%. CONCLUSION: Had the ClearSight™ been known to the surgeon intraoperatively, the reoperation rate would have been reduced by 83% for invasive carcinoma, from 10% to 2%, and 50% for DCIS, from 30% to 15% reoperations. A trial designed to examine the impact on reoperation rates is currently ongoing. John Wiley and Sons Inc. 2021-11-01 2022-03 /pmc/articles/PMC9298117/ /pubmed/34724205 http://dx.doi.org/10.1002/jso.26721 Text en © 2021 The Authors. Journal of Surgical Oncology published by Wiley Periodicals LLC https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Breast Thill, Marc Szwarcfiter, Iris Kelling, Katharina van Haasteren, Viviane Kolka, Eyal Noelke, Josefa Peles, Zachi Papa, Moshe Aulmann, Sebastian Allweis, Tanir Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study |
title | Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study |
title_full | Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study |
title_fullStr | Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study |
title_full_unstemmed | Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study |
title_short | Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight™ system in breast‐conserving surgery—Results from a postmarketing study |
title_sort | magnetic resonance imaging system for intraoperative margin assessment for dcis and invasive breast cancer using the clearsight™ system in breast‐conserving surgery—results from a postmarketing study |
topic | Breast |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9298117/ https://www.ncbi.nlm.nih.gov/pubmed/34724205 http://dx.doi.org/10.1002/jso.26721 |
work_keys_str_mv | AT thillmarc magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy AT szwarcfiteriris magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy AT kellingkatharina magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy AT vanhaasterenviviane magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy AT kolkaeyal magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy AT noelkejosefa magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy AT peleszachi magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy AT papamoshe magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy AT aulmannsebastian magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy AT allweistanir magneticresonanceimagingsystemforintraoperativemarginassessmentfordcisandinvasivebreastcancerusingtheclearsightsysteminbreastconservingsurgeryresultsfromapostmarketingstudy |