Cargando…
Assessment of Device Neoendothelialization With Cardiac Computed Tomography Angiography After Transcatheter Closure of Atrial Septal Defect
Although the transcatheter closure of atrial septal defect was established as the treatment of choice several decades ago, the process of device neoendothelialization (NE) in humans is not well understood. We aimed to measure the extent of device NE using cardiac computed tomography angiography and...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9298151/ https://www.ncbi.nlm.nih.gov/pubmed/35861980 http://dx.doi.org/10.1161/CIRCIMAGING.122.014138 |
_version_ | 1784750639551610880 |
---|---|
author | Kim, Ah Young Woo, Wongi Lim, Beom Jin Jung, Jo Won Young Choi, Jae Kim, Young Jin |
author_facet | Kim, Ah Young Woo, Wongi Lim, Beom Jin Jung, Jo Won Young Choi, Jae Kim, Young Jin |
author_sort | Kim, Ah Young |
collection | PubMed |
description | Although the transcatheter closure of atrial septal defect was established as the treatment of choice several decades ago, the process of device neoendothelialization (NE) in humans is not well understood. We aimed to measure the extent of device NE using cardiac computed tomography angiography and analyze its risk factors. METHODS: Between January 2005 and February 2021, we retrospectively reviewed 164 devices of 112 patients on cardiac computed tomography angiography. We investigated device shape, contrast opacification within the device that differentiated device NE, and device-related thrombosis or vegetation. Risk factor analysis for major adverse cardiovascular events and incomplete NE according to the postprocedural period was performed. RESULTS: Seventy patients (62.5%) were women, with a median (range) age at the time of device closure of 44.5 (0.6–79.2) years. The mean (±SD) defect size was 16.6 (±7.8) mm, and patients were followed for 35.9±33.9 months. After 6 months of device implantation, 35% of the devices (42/120) had incomplete NE. The intensity of intradevice opacification shifted from complete to partial or nonopacification over time (P<0.001), and a similar pattern was observed in the shunt flow (P<0.001). The bulkiness of devices also decreased in proportion to the postprocedural period (P<0.001). Risk analysis revealed device diameter (hazard ratio, 1.18 [95% CI, 1.04–1.27]; P<0.001) as the only significant factor of incomplete NE and major adverse events. CONCLUSIONS: Incomplete NE of atrial septal defect devices was identified on cardiac computed tomography angiography in significant numbers after 6 months of the procedure. The device diameter was related to incomplete NE and major adverse events. Further prospective and multicenter studies are warranted to validate this new assessment of device NE. |
format | Online Article Text |
id | pubmed-9298151 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-92981512022-08-02 Assessment of Device Neoendothelialization With Cardiac Computed Tomography Angiography After Transcatheter Closure of Atrial Septal Defect Kim, Ah Young Woo, Wongi Lim, Beom Jin Jung, Jo Won Young Choi, Jae Kim, Young Jin Circ Cardiovasc Imaging Original Articles Although the transcatheter closure of atrial septal defect was established as the treatment of choice several decades ago, the process of device neoendothelialization (NE) in humans is not well understood. We aimed to measure the extent of device NE using cardiac computed tomography angiography and analyze its risk factors. METHODS: Between January 2005 and February 2021, we retrospectively reviewed 164 devices of 112 patients on cardiac computed tomography angiography. We investigated device shape, contrast opacification within the device that differentiated device NE, and device-related thrombosis or vegetation. Risk factor analysis for major adverse cardiovascular events and incomplete NE according to the postprocedural period was performed. RESULTS: Seventy patients (62.5%) were women, with a median (range) age at the time of device closure of 44.5 (0.6–79.2) years. The mean (±SD) defect size was 16.6 (±7.8) mm, and patients were followed for 35.9±33.9 months. After 6 months of device implantation, 35% of the devices (42/120) had incomplete NE. The intensity of intradevice opacification shifted from complete to partial or nonopacification over time (P<0.001), and a similar pattern was observed in the shunt flow (P<0.001). The bulkiness of devices also decreased in proportion to the postprocedural period (P<0.001). Risk analysis revealed device diameter (hazard ratio, 1.18 [95% CI, 1.04–1.27]; P<0.001) as the only significant factor of incomplete NE and major adverse events. CONCLUSIONS: Incomplete NE of atrial septal defect devices was identified on cardiac computed tomography angiography in significant numbers after 6 months of the procedure. The device diameter was related to incomplete NE and major adverse events. Further prospective and multicenter studies are warranted to validate this new assessment of device NE. Lippincott Williams & Wilkins 2022-07-19 /pmc/articles/PMC9298151/ /pubmed/35861980 http://dx.doi.org/10.1161/CIRCIMAGING.122.014138 Text en © 2022 The Authors. https://creativecommons.org/licenses/by-nc-nd/4.0/Circulation: Cardiovascular Imaging is published on behalf of the American Heart Association, Inc., by Wolters Kluwer Health, Inc. This is an open access article under the terms of the Creative Commons Attribution Non-Commercial-NoDerivs (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use, distribution, and reproduction in any medium, provided that the original work is properly cited, the use is noncommercial, and no modifications or adaptations are made. |
spellingShingle | Original Articles Kim, Ah Young Woo, Wongi Lim, Beom Jin Jung, Jo Won Young Choi, Jae Kim, Young Jin Assessment of Device Neoendothelialization With Cardiac Computed Tomography Angiography After Transcatheter Closure of Atrial Septal Defect |
title | Assessment of Device Neoendothelialization With Cardiac Computed Tomography Angiography After Transcatheter Closure of Atrial Septal Defect |
title_full | Assessment of Device Neoendothelialization With Cardiac Computed Tomography Angiography After Transcatheter Closure of Atrial Septal Defect |
title_fullStr | Assessment of Device Neoendothelialization With Cardiac Computed Tomography Angiography After Transcatheter Closure of Atrial Septal Defect |
title_full_unstemmed | Assessment of Device Neoendothelialization With Cardiac Computed Tomography Angiography After Transcatheter Closure of Atrial Septal Defect |
title_short | Assessment of Device Neoendothelialization With Cardiac Computed Tomography Angiography After Transcatheter Closure of Atrial Septal Defect |
title_sort | assessment of device neoendothelialization with cardiac computed tomography angiography after transcatheter closure of atrial septal defect |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9298151/ https://www.ncbi.nlm.nih.gov/pubmed/35861980 http://dx.doi.org/10.1161/CIRCIMAGING.122.014138 |
work_keys_str_mv | AT kimahyoung assessmentofdeviceneoendothelializationwithcardiaccomputedtomographyangiographyaftertranscatheterclosureofatrialseptaldefect AT woowongi assessmentofdeviceneoendothelializationwithcardiaccomputedtomographyangiographyaftertranscatheterclosureofatrialseptaldefect AT limbeomjin assessmentofdeviceneoendothelializationwithcardiaccomputedtomographyangiographyaftertranscatheterclosureofatrialseptaldefect AT jungjowon assessmentofdeviceneoendothelializationwithcardiaccomputedtomographyangiographyaftertranscatheterclosureofatrialseptaldefect AT youngchoijae assessmentofdeviceneoendothelializationwithcardiaccomputedtomographyangiographyaftertranscatheterclosureofatrialseptaldefect AT kimyoungjin assessmentofdeviceneoendothelializationwithcardiaccomputedtomographyangiographyaftertranscatheterclosureofatrialseptaldefect |