Cargando…

Effect of the reaction temperature on the prothrombin time and the apparent International Normalized Ratio determined with International Standards for thromboplastins

INTRODUCTION: The definition of the International Normalized Ratio (INR) depends on a reference measurement procedure for the prothrombin time (PT) determined with international standards for thromboplastins. The agreed water bath temperature for PT determination in the reference measurement procedu...

Descripción completa

Detalles Bibliográficos
Autores principales: Van Den Besselaar, Antonius M. H. P., Cobbaert, Christa M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9299017/
https://www.ncbi.nlm.nih.gov/pubmed/34747561
http://dx.doi.org/10.1111/ijlh.13737
_version_ 1784750848121765888
author Van Den Besselaar, Antonius M. H. P.
Cobbaert, Christa M.
author_facet Van Den Besselaar, Antonius M. H. P.
Cobbaert, Christa M.
author_sort Van Den Besselaar, Antonius M. H. P.
collection PubMed
description INTRODUCTION: The definition of the International Normalized Ratio (INR) depends on a reference measurement procedure for the prothrombin time (PT) determined with international standards for thromboplastins. The agreed water bath temperature for PT determination in the reference measurement procedure is 37°C. The aim of the study was to assess the influence of small deviations of the agreed reaction temperature on PT and INR determined with World Health Organization international standards for thromboplastins rTF/16 (recombinant human) and RBT/16 (rabbit brain). METHODS: Prothrombin time was determined, with a manual hook technique, in glass test tubes in a water bath at a controlled temperature. The PT reaction temperatures were varied between 28 and 40°C. Pooled normal plasma and pooled coumarin plasma (INR ≈ 2.8) were used as test plasmas. The data were fitted to a quadratic relationship between PT and temperature. RESULTS: Prothrombin times with rTF/16 were shortened by increasing the reaction temperature up to approximately 39‐40°C. PTs with RBT/16 were shortened by increasing the reaction temperature up to approximately 34‐37°C, but were prolonged at higher temperatures. The apparent INR change of the coumarin plasma at 37.0°C was 0.06/°C and 0.11/°C for rTF/16 and RBT/16, respectively. CONCLUSIONS: Reaction temperature had a significant effect on PT and the apparent INR with the International Standards. At 37.0°C, the apparent INR of coumarin plasma determined with RBT/16 was more responsive to temperature change than the apparent INR determined with rTF/16. The required accuracy of the water bath temperature should be 37.0 ± 0.1°C.
format Online
Article
Text
id pubmed-9299017
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-92990172022-07-21 Effect of the reaction temperature on the prothrombin time and the apparent International Normalized Ratio determined with International Standards for thromboplastins Van Den Besselaar, Antonius M. H. P. Cobbaert, Christa M. Int J Lab Hematol Original Articles INTRODUCTION: The definition of the International Normalized Ratio (INR) depends on a reference measurement procedure for the prothrombin time (PT) determined with international standards for thromboplastins. The agreed water bath temperature for PT determination in the reference measurement procedure is 37°C. The aim of the study was to assess the influence of small deviations of the agreed reaction temperature on PT and INR determined with World Health Organization international standards for thromboplastins rTF/16 (recombinant human) and RBT/16 (rabbit brain). METHODS: Prothrombin time was determined, with a manual hook technique, in glass test tubes in a water bath at a controlled temperature. The PT reaction temperatures were varied between 28 and 40°C. Pooled normal plasma and pooled coumarin plasma (INR ≈ 2.8) were used as test plasmas. The data were fitted to a quadratic relationship between PT and temperature. RESULTS: Prothrombin times with rTF/16 were shortened by increasing the reaction temperature up to approximately 39‐40°C. PTs with RBT/16 were shortened by increasing the reaction temperature up to approximately 34‐37°C, but were prolonged at higher temperatures. The apparent INR change of the coumarin plasma at 37.0°C was 0.06/°C and 0.11/°C for rTF/16 and RBT/16, respectively. CONCLUSIONS: Reaction temperature had a significant effect on PT and the apparent INR with the International Standards. At 37.0°C, the apparent INR of coumarin plasma determined with RBT/16 was more responsive to temperature change than the apparent INR determined with rTF/16. The required accuracy of the water bath temperature should be 37.0 ± 0.1°C. John Wiley and Sons Inc. 2021-11-08 2022-04 /pmc/articles/PMC9299017/ /pubmed/34747561 http://dx.doi.org/10.1111/ijlh.13737 Text en © 2021 The Authors. International Journal of Laboratory Hematology published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Articles
Van Den Besselaar, Antonius M. H. P.
Cobbaert, Christa M.
Effect of the reaction temperature on the prothrombin time and the apparent International Normalized Ratio determined with International Standards for thromboplastins
title Effect of the reaction temperature on the prothrombin time and the apparent International Normalized Ratio determined with International Standards for thromboplastins
title_full Effect of the reaction temperature on the prothrombin time and the apparent International Normalized Ratio determined with International Standards for thromboplastins
title_fullStr Effect of the reaction temperature on the prothrombin time and the apparent International Normalized Ratio determined with International Standards for thromboplastins
title_full_unstemmed Effect of the reaction temperature on the prothrombin time and the apparent International Normalized Ratio determined with International Standards for thromboplastins
title_short Effect of the reaction temperature on the prothrombin time and the apparent International Normalized Ratio determined with International Standards for thromboplastins
title_sort effect of the reaction temperature on the prothrombin time and the apparent international normalized ratio determined with international standards for thromboplastins
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9299017/
https://www.ncbi.nlm.nih.gov/pubmed/34747561
http://dx.doi.org/10.1111/ijlh.13737
work_keys_str_mv AT vandenbesselaarantoniusmhp effectofthereactiontemperatureontheprothrombintimeandtheapparentinternationalnormalizedratiodeterminedwithinternationalstandardsforthromboplastins
AT cobbaertchristam effectofthereactiontemperatureontheprothrombintimeandtheapparentinternationalnormalizedratiodeterminedwithinternationalstandardsforthromboplastins