Cargando…
Ablation Index‐guided point‐by‐point ablation versus Grid annotation‐guided dragging for pulmonary vein isolation: A randomized controlled trial
INTRODUCTION: Radiofrequency (RF) atrial fibrillation (AF) ablation using a catheter dragging technique may shorten procedural duration and improve durability of pulmonary vein isolation (PVI) by creating uninterrupted linear ablation lesions. We compared a novel AF ablation approach guided by Grid...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9299027/ https://www.ncbi.nlm.nih.gov/pubmed/34820931 http://dx.doi.org/10.1111/jce.15294 |
_version_ | 1784750850463236096 |
---|---|
author | Mulder, Mark J. Kemme, Michiel J. B. Hopman, Luuk H. G. A. Hagen, Amaya M. D. van de Ven, Peter M. Hauer, Herbert A. Tahapary, Giovanni J. M. van Rossum, Albert C. Allaart, Cornelis P. |
author_facet | Mulder, Mark J. Kemme, Michiel J. B. Hopman, Luuk H. G. A. Hagen, Amaya M. D. van de Ven, Peter M. Hauer, Herbert A. Tahapary, Giovanni J. M. van Rossum, Albert C. Allaart, Cornelis P. |
author_sort | Mulder, Mark J. |
collection | PubMed |
description | INTRODUCTION: Radiofrequency (RF) atrial fibrillation (AF) ablation using a catheter dragging technique may shorten procedural duration and improve durability of pulmonary vein isolation (PVI) by creating uninterrupted linear ablation lesions. We compared a novel AF ablation approach guided by Grid annotation allowing for “drag lesions” with a standard point‐by‐point ablation approach in a single‐center randomized study. METHODS: Eighty‐eight paroxysmal or persistent AF patients were randomized 1:1 to undergo RF‐PVI with either a catheter dragging ablation technique guided by Grid annotation or point‐by‐point ablation guided by Ablation Index (AI) annotation. In the Grid annotation arm, ablation was visualized using 1 mm³ grid points coloring red after meeting predefined stability and contact force criteria. In the AI annotation arm, ablation lesions were created in a point‐by‐point fashion with AI target values set at 380 and 500 for posterior/inferior and anterior/roof segments, respectively. Patients were followed up for 12 months after PVI using ECGs, 24‐h Holter monitoring and a mobile‐based one‐lead ECG device. RESULTS: Procedure time was not different between the two randomization arms (Grid annotation 71 ± 19 min, AI annotation 72 ± 26 min, p = .765). RF time was significantly longer in the Grid annotation arm compared with the AI annotation arm (49 ± 8 min vs. 37 ± 8 min, respectively, p < .001). Atrial tachyarrhythmia recurrence was documented in 10 patients (23%) in the Grid annotation arm compared with 19 patients (42%) in the AI annotation arm with time to recurrence not reaching statistical significance (p = .074). CONCLUSIONS: This study shows that a Grid annotation‐guided dragging approach provides an alternative to point‐by‐point RF‐PVI using AI annotation. |
format | Online Article Text |
id | pubmed-9299027 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-92990272022-07-21 Ablation Index‐guided point‐by‐point ablation versus Grid annotation‐guided dragging for pulmonary vein isolation: A randomized controlled trial Mulder, Mark J. Kemme, Michiel J. B. Hopman, Luuk H. G. A. Hagen, Amaya M. D. van de Ven, Peter M. Hauer, Herbert A. Tahapary, Giovanni J. M. van Rossum, Albert C. Allaart, Cornelis P. J Cardiovasc Electrophysiol Original Articles INTRODUCTION: Radiofrequency (RF) atrial fibrillation (AF) ablation using a catheter dragging technique may shorten procedural duration and improve durability of pulmonary vein isolation (PVI) by creating uninterrupted linear ablation lesions. We compared a novel AF ablation approach guided by Grid annotation allowing for “drag lesions” with a standard point‐by‐point ablation approach in a single‐center randomized study. METHODS: Eighty‐eight paroxysmal or persistent AF patients were randomized 1:1 to undergo RF‐PVI with either a catheter dragging ablation technique guided by Grid annotation or point‐by‐point ablation guided by Ablation Index (AI) annotation. In the Grid annotation arm, ablation was visualized using 1 mm³ grid points coloring red after meeting predefined stability and contact force criteria. In the AI annotation arm, ablation lesions were created in a point‐by‐point fashion with AI target values set at 380 and 500 for posterior/inferior and anterior/roof segments, respectively. Patients were followed up for 12 months after PVI using ECGs, 24‐h Holter monitoring and a mobile‐based one‐lead ECG device. RESULTS: Procedure time was not different between the two randomization arms (Grid annotation 71 ± 19 min, AI annotation 72 ± 26 min, p = .765). RF time was significantly longer in the Grid annotation arm compared with the AI annotation arm (49 ± 8 min vs. 37 ± 8 min, respectively, p < .001). Atrial tachyarrhythmia recurrence was documented in 10 patients (23%) in the Grid annotation arm compared with 19 patients (42%) in the AI annotation arm with time to recurrence not reaching statistical significance (p = .074). CONCLUSIONS: This study shows that a Grid annotation‐guided dragging approach provides an alternative to point‐by‐point RF‐PVI using AI annotation. John Wiley and Sons Inc. 2021-11-24 2022-01 /pmc/articles/PMC9299027/ /pubmed/34820931 http://dx.doi.org/10.1111/jce.15294 Text en © 2021 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals LLC https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles Mulder, Mark J. Kemme, Michiel J. B. Hopman, Luuk H. G. A. Hagen, Amaya M. D. van de Ven, Peter M. Hauer, Herbert A. Tahapary, Giovanni J. M. van Rossum, Albert C. Allaart, Cornelis P. Ablation Index‐guided point‐by‐point ablation versus Grid annotation‐guided dragging for pulmonary vein isolation: A randomized controlled trial |
title | Ablation Index‐guided point‐by‐point ablation versus Grid annotation‐guided dragging for pulmonary vein isolation: A randomized controlled trial |
title_full | Ablation Index‐guided point‐by‐point ablation versus Grid annotation‐guided dragging for pulmonary vein isolation: A randomized controlled trial |
title_fullStr | Ablation Index‐guided point‐by‐point ablation versus Grid annotation‐guided dragging for pulmonary vein isolation: A randomized controlled trial |
title_full_unstemmed | Ablation Index‐guided point‐by‐point ablation versus Grid annotation‐guided dragging for pulmonary vein isolation: A randomized controlled trial |
title_short | Ablation Index‐guided point‐by‐point ablation versus Grid annotation‐guided dragging for pulmonary vein isolation: A randomized controlled trial |
title_sort | ablation index‐guided point‐by‐point ablation versus grid annotation‐guided dragging for pulmonary vein isolation: a randomized controlled trial |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9299027/ https://www.ncbi.nlm.nih.gov/pubmed/34820931 http://dx.doi.org/10.1111/jce.15294 |
work_keys_str_mv | AT muldermarkj ablationindexguidedpointbypointablationversusgridannotationguideddraggingforpulmonaryveinisolationarandomizedcontrolledtrial AT kemmemichieljb ablationindexguidedpointbypointablationversusgridannotationguideddraggingforpulmonaryveinisolationarandomizedcontrolledtrial AT hopmanluukhga ablationindexguidedpointbypointablationversusgridannotationguideddraggingforpulmonaryveinisolationarandomizedcontrolledtrial AT hagenamayamd ablationindexguidedpointbypointablationversusgridannotationguideddraggingforpulmonaryveinisolationarandomizedcontrolledtrial AT vandevenpeterm ablationindexguidedpointbypointablationversusgridannotationguideddraggingforpulmonaryveinisolationarandomizedcontrolledtrial AT hauerherberta ablationindexguidedpointbypointablationversusgridannotationguideddraggingforpulmonaryveinisolationarandomizedcontrolledtrial AT tahaparygiovannijm ablationindexguidedpointbypointablationversusgridannotationguideddraggingforpulmonaryveinisolationarandomizedcontrolledtrial AT vanrossumalbertc ablationindexguidedpointbypointablationversusgridannotationguideddraggingforpulmonaryveinisolationarandomizedcontrolledtrial AT allaartcornelisp ablationindexguidedpointbypointablationversusgridannotationguideddraggingforpulmonaryveinisolationarandomizedcontrolledtrial |